DOCUMENT
84 -- PAPR Respiratory System - Attachment
- Notice Date
- 8/22/2017
- Notice Type
- Attachment
- NAICS
- 315990
— Apparel Accessories and Other Apparel Manufacturing
- Contracting Office
- Department of Veterans Affairs;VISN 7 Network Contracting Activity;501 Greene Street;Hatcher Building - Suite 2;Augusta GA 30901
- ZIP Code
- 30901
- Solicitation Number
- VA24717R0865
- Response Due
- 8/23/2017
- Archive Date
- 11/21/2017
- Point of Contact
- Sterlyn frazier
- E-Mail Address
-
3-0188
- Small Business Set-Aside
- N/A
- Description
- Pre-solicitation Notice 3M Powered Air Purifying Respirator (PAPR) for the Charlie Norwood VA Medical Center The Network Contracting Office (NCO) Seven (7) has a need for eight (8) PAPR Systems for the Charlie Norwood VAMC located in Augusta, Georgia. Offerors shall provide a responsible proposal for the Brand Name equipment as specified in the salient characteristics. The North American Industry Classification System NAICS Code is 315990 with a Size Standard of 500 employees; the PSC is 8415. This requirement will be issued as a Firm Fixed Priced 100% SDVOSB Set-Aside acquisition. Offerors are responsible for ensuring their proposal package is received by the exact time and date specified in the solicitation. Equipment must be Brand Name; no other substitutions will be considered and all equipment shall be new. Prospective bidders must maintain an active registration in sam.gov and have and must be a verifiable SDVOSB on the Vendor Information Page (VIP) to be considered for this government contract. Contract Specialist Sterlyn Frazier @ 706-733-0188, x1119 or at sterlyn.frazier@va.gov. SALIENT CHARACTERISTICS (Brand Name Only) Sentinel XL CBRN PAPR Compliance requirement: Listed on the FEMA Responder Knowledge Base AEL. Must be NIOSH approved CAP 2 loose fitting CBRN PAPR Required features: NIOSH Rated Capacity 2 protection from CBRN contaminants Capacity 2 PAPR allows for 30 minute chemical, biological, radiological and nuclear contaminant protection. Capacity 2 offers twice the duration of Capacity 1 PAPRs therefore uses less filters. Flat-Folded Butyl Hood with Butyl Taped Seams Flat folded hood offers a unique design that saves storage space and prevents face shield damage. Butyl taped seams are strong and offer longer life. Alkaline Battery Pack Takes (5) D-Cell batteries and offers the best solution for PAPR long term storage. Note: Battery Packs may vary in the number and type of batteries that are required in the Pack. Specific types of Battery Packs are usually made to fit only the manufacturer s PAPR product; they manufactures for exclusive use. Back Pack Configuration The Back-Pack configuration is required because it is self-contained, NIOSH approved, and can be quickly deployed for use. There is no assembly of individual pieces of the PAPR and the butyl hood, and the entire PAPR unit is to be stored within the back pack. Required components: Size Universal, Cartridge Type CBRN, Battery NiMH, Suspension Removable/Replaceable Headband, Lens Material Polycarbonate, Hood Material Butyl Coated Nylon, Standards NIOSH Approved TC-23C-2312, Includes Butyl Hood Assembly, Blower, NiMH Battery, Quick-Loc Waist Belt, Flow Meter, Battery Charger, 3 C Sentinel XL CBRN PAPR Sentinel XL - CBRN System Components are: Blower with battery 3 CBRN filters Lay flat butyl hood Battery charger (for rechargeable systems) Flow meter User's manual Waist belt System available in (optional backpack) configuration. CBRN Cartridges, CBRN Backpack Sentinel XL - CBRN Filter Cartridges: CBRN Filter Cartridges, Size Universal, Cartridge Type CBRN Cartridges, Color Code Black, For Use With CBRN System, NIOSH Approval NIOSH Approved TC-23C-2312, Includes 3 CBRN Cartridges Sentinel XL Battery Pack, D, PK 5: Battery Pack, Size D, Battery Alkaline For Use With Sentinel XL HP System, NIOSH Approval NIOSH Approved TC-23C-2312, Includes 5 Duracell Batteries Sentinel XL Antimicrobial Headband, PK 5: Headbands, Size Universal, Color Code Gray, For Use With CBRN System, Includes 5 Antimicrobial Headbands
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AuVAMC/VAMCCO80220/VA24717R0865/listing.html)
- Document(s)
- Attachment
- File Name: VA247-17-R-0865 VA247-17-R-0865_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3748310&FileName=VA247-17-R-0865-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3748310&FileName=VA247-17-R-0865-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA247-17-R-0865 VA247-17-R-0865_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3748310&FileName=VA247-17-R-0865-000.docx)
- Record
- SN04641376-W 20170824/170822232848-8cb59efbb5ee1de726c57f227b6ec2e5 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |