SOLICITATION NOTICE
66 -- PLC Controls Stub Shaft at Truman Dam - Solicitation & Attachments
- Notice Date
- 8/22/2017
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 335314
— Relay and Industrial Control Manufacturing
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Kansas City, Attn: CENWK-CT, 635 Federal Building 60l East 12th Street, Kansas City, Missouri, 64106-2896, United States
- ZIP Code
- 64106-2896
- Solicitation Number
- W912DQ17Q1004
- Archive Date
- 9/21/2017
- Point of Contact
- Andrew Minnix, Phone: 8163892218, Hilary O. Meckel, Phone: 8163893500
- E-Mail Address
-
andrew.m.minnix@usace.army.mil, hilary.o.meckel@usace.army.mil
(andrew.m.minnix@usace.army.mil, hilary.o.meckel@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Attachment 1 Combined Synopsis Solicitation This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number for this acquisition is W912DQ17Q1004 and it is being issued as a Request for Quotes (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-95. This RFP shall be set aside for small businesses and the associated North American Industry Classification System (NAICS) code is 335314 and the business size standard is 750 Employees. FAR 52.212-1, Instructions to Offerors - Commercial, does apply to this acquisition with no addenda to the provision. FAR 52.212-2, Evaluation - Commercial Items, does apply to this acquisition. The specific evaluation criteria to be included are detailed in Section M of this combined synopsis/solicitation. Offerors must include a completed copy of FAR 52.212-3, Offeror Representations and Certifications - Commercial Items, with its offer. This provision is included in Section K of this combined synopsis/solicitation. FAR 52.212-4, Contract Terms and Conditions - Commercial Items, does apply to this acquisition with no addenda to the provision. FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items, applies to this acquisition. The specific clauses required are detailed in Section I of this combined synopsis/solicitation. HST STUB SHAFT PLC CONTROLS HARRY S. TRUMAN LAKE This project replaces a portion of the components of the stub shaft bearing oil temperature control system. Each of the six power generation units at the Harry S. Truman Power Plant has a separate stub shaft bearing control system. This project will replace all six stub shaft bearing control systems. The portion of the system to be replaced includes raw water piping and electrical controls. This project will supply and install the components to be replaced. No oil lines are anticipated to be impacted by this project. Oil currently travels from the stub shaft bearings through a raw water cooler. Two valves will be replaced with a single larger modulating valve. All valves are less than 4 inches in diameter. The electrical controls include installation of oil temperature sensors in the stub shaft bearings. A Programmable Logic Controller (PLC) will be installed and will use feedback from the oil temperature sensor to control the installed modulating raw water valve. The PLC will also control the oil heater and pressure pumps. Quote and Solicitation return pages shall be returned to: Andrew.m.minnix@usace.army.mil -OR- Andrew Minnix ATTN: CECT-NWK-C 647 Federal Building 601 E 12th Street, Room 647 Kansas City, Missouri 64106 ALL PROPOSALS ARE DUE NO LATER THAN 6 SEPTEMBER 2017 AT 2:00 PM CENTRAL. Quotes must contain the following information: Programmable Logic Controller Product Data: Include the product cutsheet(s) for the following, PLC components; CPU, memory, I/O capacity, nonvolatile retention and I/O modules. Control System Components Product Data: Include the product cutsheet(s) for the following control system components; modulating control valve, two-way modulating valve, and temperature sensor. OFFERORS INTERESTED IN RESPONDING TO THIS RFP MUST SUBMIT THEIR PROPOSAL ON THE ATTACHED SYNOPSIS/SOLICITATION. Award will be made to the offeror providing the best value. Any questions regarding this synopsis/solicitation must be submitted by e-mail to the point of contact below. The System for Award Management (SAM) is a Federal Government owned and operated FREE web site that consolidates the capabilities in CCR, ORCA, and EPLS. All vendors must verify their information through this web site. If you were previously registered in CCR and ORCA, your organization's information is already in SAM. You just need to set up a SAM account and migrate your CCR roles. If you were previously registered in CCR, your registration should have been moved to SAM, and you just need to open an account, see the following link for instructions: https://www.sam.gov/sam/transcript/Quick_Guide_for_Updating_or_Renewing_CCR-SAM_Registrations.pdf If you were not previously registered, please go to https://www.sam.gov. Instructions for new registration are also located at the following link https://www.sam.gov/sam/transcript/Quick_Guide_for_Contract_Registrations.pdf to register. Contractors may obtain information on registration and annual confirmation requirements via the Internet at http://www.sam.gov or by calling (866) 606-8220. If you have questions about Government procurements in general or need assistance in the preparation of your quote, a local Procurement Technical Assistance Center (PTAC) may be able to help. The Procurement Technical Assistance Program was authorized by Congress in 1985 in an effort to expand the number of businesses capable of participating in the Government marketplace. To locate a PTAC near you, go to http://www.aptac-us.org/contracting-assistance/. The Government reserves the right to cancel this combined synopsis/solicitation. Any questions should be sent to Andrew Minnix at (816) 389-2218 or at andrew.m.minnix@usace.army.mil. (End of Synopsis)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA41/W912DQ17Q1004/listing.html)
- Place of Performance
- Address: Truman Dam, Warsaw, Missouri, 65355, United States
- Zip Code: 65355
- Zip Code: 65355
- Record
- SN04641414-W 20170824/170822232904-338a8dfd0feabbb8b63fa2cee96802f2 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |