DOCUMENT
65 -- VNG System (VA-17-121159) - Attachment
- Notice Date
- 8/23/2017
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;VISN/18PHX;777 E. Missouri, Suite 300;Phoenix AZ 85014
- ZIP Code
- 85014
- Solicitation Number
- VA25817Q0800
- Response Due
- 8/28/2017
- Archive Date
- 9/27/2017
- Point of Contact
- Timothy Saffles
- E-Mail Address
-
y.saffles@va.gov<br
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT NOTICE. This is not a request for proposals. The SAVAHCS Audiology clinic requires replacement of its vestibular testing equipment used for Videonystagmography (VNG) diagnostic testing system. The current system in use is the ICS Chartr 200 which includes a water caloric stimulator, video goggles, lap top and accompanying software. The scope of this award includes the equipment, software, installation, in-service and biomedical staff training. Deliverables: Video goggles: Four channel tracking right and left eyes in both the horizontal and vertical planes Start button built into the infrared goggles in order to start recordings with positionting patients heads during dynamic positioning testing Automatic eye centering capability Wall mounted flat screen for near full field optikinetic tracking testing Water caloric stimulator: Compact size to save space and reduce amount of distilled water used to operate Computer: Tower PC with accompanying monitor, keyboard, mouse, software and 23 monitor Installation & training Award to include installation Award to include in-service for SAVAHCS Audiology staff Performance maintenance training for SAVAHCS Biomedical staff desirable but not mandatory Minimum one year warrantee on parts and equipment Supplier will install equipment in the SAVAHCS Audiology department within 30 days of award. Supplier will conduct an in-service to the SAVAHCS Audiology staff within one week of install. Supplier will provide a one day equipment maintenance training to one SAVAHCS Biomedical Engineering staff person. If training is provided offsite the vendor will assume any travel, lodging and per diem costs that may be associated with the training. Training onsite at SAVAHCS is acceptable. Videonystagmography (VNG) systems that meet the requirements for diagnostic testing in the SAVAHCS Audiology clinic will meet the following specifications: Water Caloric Irrigator Water flow rate 250cc/30 sec Water temperature 30C and 44C Water fill and heat cycle per each irrigation External water reservoir Temperature stability of + 1C Tip accuracy of + 1C 30 sec irrigation time Compact case dimension not larger than 35cm x 30cm x 21 cm Irrigator weight no heavier than 6 kg Water hose length no shorter than 3m Voltage requirements: 110-130 VAC @ 50-60 Hz, 220-240 VAC @ 50-60 Hz Power consumption 600 VA Chassis leakage current < 300 uA (single fault) USB 1.1 computer connection Must meet ANSI standard S3.45-2009 Video Goggles Full field view with a minimum +/- 45 degrees horizontal and +20, -25 degrees vertical Integrated external focus knob and built-in software controlled fixation lights Mirrors mounted below eye level Single click eye centering Weight no more than 8 oz without cover Software controlled fixation and side lights Utilize high speed Firewire cameras that can record up to 100 Hz Goggle mounted button switch to allow start, stop and escape testing in Dix-Hallpike and Positional tests Hardware Mid-Tower Windows 8.1 PC, Intel Processor, 500 GB HD, DVD + RW, 4GB Ram, Pro 64-bit, keyboard, mouse, 23 touch LCD monitor, USB room Camera with microphone 48 Class TV with wall-mount Wireless remote control The intent of the procurement is to award a firm-fixed price contract. Please see the below items list: Product # Description U/M Qty 001 VNG, SOFTWARE SACCADE, SMOOTH PURSUIT, OPTOKINETIC, CALORIC, GAZE, POSITIONAL, AND HALLPIKE TESTS VIDEO GOGGLES BINOCULAR USB DIGITAL CAMERAS WITH REMOVABLE EA 1 002 CALORIC IRRIGATOR 30C AND 44C WATER TEMPERATURES, PUSHBUTTON START/STOP SWITCH ON LIGHTED HANDLE, FLOW RATE 250cc/ 30 SECONDS, EXTERNAL WATER RESERVOIR, THREE METER IRRIGATOR HOSE, USB INTER EA 1 003 INSTALLATION EA 1 Delivery FOB: Destination to: Southern Arizona VA Healthcare System, Tucson, AZ The applicable NAICS code is 334510. The resulting contract will be a firm fixed price order. The delivery term is to be 30 calendar days ARO, with no options included. PLEASE INDICATE IN YOUR RESPONSE YOUR BUSINESS SIZE AND IF YOU ARE A MANUFACTURER OR DISTRIBUTOR. IF THE ITEMS ARE AVAILABLE ON AN FSS SCHEDULE, PLEASE INCLUDE THE FSS SCHEDULE NUMBER. ALL RESPONDANTS MUST BE MANUFACTURERS OR AUTHORIZED DISTRIBUTORS. NO REFURBISHED OR GRAY MARKET ITEMS WILL BE ACCEPTED. It is anticipated that a Request for Quotes will be issued in August 2017. Award of a firm fixed price contract is contemplated by September 2017. This notice is published to conduct market research to determine if there is a sufficient number of certified Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), capable of performing the requirements to warrant a socio-economic set-aside or full & open competition. It is strongly recommended that interested parties register in the US Department of Veterans Affairs Vet Biz database and the Small Business Administration (SBA) database. Registration may be accomplished at http://www.vip.vetbiz.gov/ and www.sba.gov/, respectively. Interested parties responding to this sources sought request shall submit the following information at a minimum: (1) company name and address, point of contact with phone number, and DUNS number; (2) documentation relating to capability of performance of residential renovation projects (including references); (3) intentions of subcontracting program to include set-asides; (4) proof of registration in the VA Vet Biz or SBA websites or intention of registration prior to submission of offers to a solicitation; (5) documentation on company s bonding capacity and limitations; (6) If you are a distributor a statement from the manufacturer that your company is an authorized distributor; (7) a statement to inform the government if you are a manufacturer or distributor; (8) any information regarding FSS Schedule availability; (9) any other pertinent company documentation. The response date to this Sources Sought notice is August 28, 2017 at 10:00 am AZ time. This market research is for informational and planning purposes only to determine if a socio-economic set-aside, or full & open competition, or sole-source procurement is appropriate. The Government will not pay any costs for responses submitted. Electronic submissions are acceptable via Timothy.Saffles@va.gov. NO ADDITIONAL INFORMATION IS AVAILABLE OTHER THAN WHAT IS NOTED HEREIN. ALL FIRMS ARE INSTRUCTED NOT TO CALL THE INDIVIDUAL VA MEDICAL CENTERS REQUESTING MORE INFORMATION.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA25817Q0800/listing.html)
- Document(s)
- Attachment
- File Name: VA258-17-Q-0800 VA258-17-Q-0800.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3752248&FileName=VA258-17-Q-0800-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3752248&FileName=VA258-17-Q-0800-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA258-17-Q-0800 VA258-17-Q-0800.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3752248&FileName=VA258-17-Q-0800-000.docx)
- Place of Performance
- Address: SAVAHCS;3601 S. 6th Ave;Tucson
- Zip Code: 85723
- Zip Code: 85723
- Record
- SN04643101-W 20170825/170823233245-a555a87466600b7532c91b76880abfb1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |