SOLICITATION NOTICE
45 -- Replace Pumps and Motors at Wells - Draft Statement of Work
- Notice Date
- 8/23/2017
- Notice Type
- Presolicitation
- NAICS
- 333911
— Pump and Pumping Equipment Manufacturing
- Contracting Office
- Department of the Air Force, Air Education and Training Command, 502d Contracting Squadron, 1655 Selfridge Avenue, JBSA Lackland, Texas, 78236-5253, United States
- ZIP Code
- 78236-5253
- Solicitation Number
- FA3016-17-U-0295
- Archive Date
- 9/12/2017
- Point of Contact
- Jack A. Caniglia, Phone: (210)671-1721, Timothy J. Hull, Phone: (210)671-1717
- E-Mail Address
-
jack.caniglia.3@us.af.mil, timothy.hull.6@us.af.mil
(jack.caniglia.3@us.af.mil, timothy.hull.6@us.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Draft Statement of Work PROJECT SCOPE Well #1 Above Ground Pump: The contractor shall furnish all supervision, labor, transportation, materials, tools, incidentals, equipment, personnel and other services necessary to replace above ground pump. Contractor shall remove old steel piping in well #1, Diameter -12 inches and replace with new steel pipe 320 feet with 7 stages along with 150 horsepower motor, speed-1770 RPM Phase-3 Voltage-460V. The pump will be tested to ensure proper operation before acceptance. Contractor shall disconnect and connect all the piping and 7 stage and all the plumbing with electrical. In addition, all services shall be performed in accordance with the latest version of the Uniform Building Code, International Building Code (IBC), Federal, State, local building codes and Texas Administrative Code (Title 30, Part 1, Chapter 334, Subchapter C, Rule 334.49). PROJECT SCOPE Well #5 Submersible Pump : The contractor shall furnish all supervision, labor, transportation, materials, tools, incidentals, equipment and personnel and other services necessary to replace submersible pump. Contractor shall remove old steel piping in well # 5 Diameter-14 inches and replace with new steel pipe 272 feet with 4 stage along with 200 horsepower motor, speed-1750 RPM Phase-3 Voltage-460V. The pump will be tested to ensure proper operation before acceptance. Contractor shall disconnect and connect all piping, submersible 4 stage and all the electrical. Contractor shall install all new pump with pipe and electrical
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LackAFBCS/FA3016-17-U-0295/listing.html)
- Place of Performance
- Address: Building 2194 and Building 3186, Joint Base San Antonio, Fort Sam Houston TX, San Antonio, Texas, 78234, United States
- Zip Code: 78234
- Zip Code: 78234
- Record
- SN04643531-W 20170825/170823233620-152128d82055d974ff6989040836ff07 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |