Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 26, 2017 FBO #5755
DOCUMENT

65 -- IOL Master 700 or equal - Attachment

Notice Date
8/24/2017
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Western New York Healthcare System;3495 Bailey Ave.;Buffalo NY 14215
 
ZIP Code
14215
 
Solicitation Number
VA24217Q1087
 
Response Due
8/29/2017
 
Archive Date
9/8/2017
 
Point of Contact
Delene Kendrick
 
E-Mail Address
7-1460
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Statement of Work (SOW) 3 Page 3 of 4 COMBINED SYNOPSIS/SOLICITATION Zeiss IOLMASTER 700 (or equal) ALBANY VA MEDICAL CENTER This is a combined synopsis/solicitation for a commercial item prepared in accordance with the format in FAR Subpart 12.6 and 13.106, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. (ii) This solicitation is issued as a request for quote (RFQ). Request for Quote will be submitted through fedbizopps.gov on RFQ reference number VA242-17-Q-0187. (iii) This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-95. (iv) This procurement is being issued as 100% set-aside for SERVICE DISABLED VETERAN OWNED SMALL BUSINESSES (SDVOSB). It is the Government s intent to issue a firm fixed price, single award as a result of this solicitation. The North American Industry Classification System (NAICS) code is 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing, with a small business size standard of 1,250 employees. This solicitation is 100% set-aside for SDVOSBs. (v) The Contractor shall provide all parts and labor necessary to deliver a ZEISS Operating System IOLMaster 700 with SWEPT Source OCT, Option Reference Image with keyboard, mouse, printer, and table IT1060. This requirement is for Zeiss brand or equal. In order to be considered an or equal product, all of the salient characteristics listed below must be met at the same quality as the requested brand name product. All products shall be delivered in new and unused/unopened condition. (vi) Description of requirement: The Albany VA Medical Center has a requirement for: (1) ea. ZEISS Operating System IOLMaster 700 (p/n 266002-1162-219-PRO) MANUFACTURERS PART NUMBERPHC115G WIDTH INCHES23-5/8 DEPTH INCHES24-1/8 HEIGHT INCHES63-3/4 INSIDE WIDTH INCHES19-1/2 INSIDE DEPTH INCHES18-3/4 INSIDE HEIGHT INCHES50 WEIGHT LBS145.0 lbs CAPACITY CUBIC FEET11.0 COLOR FINISHStainless Steel DOOR TYPEGlass LOCK TYPEKey SHELF QUANTITY4 STYLEFree Standing SHELF TYPEWire TEMPERATURE RANGE120 to 150 °F TYPEWarming Cabinets VOLTAGE115V AC HERTZ60 Hz APPROVAL/REGULATIONSETL LIMITED WARRANTY1 Year on Parts & Labor THERMOSTAT TYPEDigital DOOR SWINGRHD AMPS5.5 SWEPT Source OCT Option Reference Image Keyboard Mouse Printer Table IT1060 Salient Characteristics: Total time from the  point of data entry to the completion of the measurement must be  130 seconds or less. Measurement range Axial length 14 38 mm   Corneal radii 5 11 mm   Anterior chamber depth 0.7 8 mm   Lens thickness 1 10 mm (phakic eye)                                             0.13 2.5 mm (pseudophakic eye)   Central corneal thickness 0.2 1.2 mm   White-to-white 8 16 mm Display scaling Axial length 0.01 mm   Corneal radii 0.01 mm   Anterior chamber depth 0.01 mm   Lens thickness 0.01 mm   Central corneal thickness 1 m   White-to-white 0.1 mm SD of repeatability4 Axial length 9 m   Corneal radii 0.10 D   Cylinder > 0.75 D axis 5.6 °   Anterior chamber depth 10 m   Lens thickness 19 m   Central corneal thickness 2 m   White-to-white 90 m IOL calculation formulas Haigis Suite [includes Haigis, Haigis-L (for eyes following myopic/hyperopic LASIK/PRK/LASEK, Haigis-T (for toric IOL power)], Hoffer ® Q, Holladay 2, SRK ®/T. Interfaces ZEISS FORUM ® eye care data management system   ZEISS computer-assisted cataract surgery system CALLISTO eye (via USB & FORUM)   Data interface for electronic medical record (EMR) / patient management systems (PMS)   Data export to USB storage media   Ethernet port for network connection and network printer Line voltage 100 240 V ± 10 % (self sensing) Line frequency 50 60 Hz Power consumption max. 150 VA Laser class 1 Delivery to: Albany VA Medical Center: 113 Holland Ave. Albany, NY 12208; FOB DESTINATION (vii) EVALUATION: Quotes will be evaluated based upon best value to the Government. Technical acceptability is based upon the ability to meet the above specifications, past performance, and pricing. Contract Administration: All contract administration matters will be handled by the following individuals: a. CONTRACTOR: b. GOVERNMENT: Contracting Officer 36C242 Delene Kendrick, delene.kendrick@va.gov, 585-297-1460 x72474 (viii) CONTRACTOR REMITTANCE ADDRESS: All payments by the Government to the contractor will be made in accordance with 52.232-34, Payment by Electronic Funds Transfer Other Than System For Award Management, (ix) INVOICES: Invoices shall be submitted upon final installation of goods (x) GOVERNMENT INVOICE ADDRESS: All Invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests. Tungsten Network http://www.tungsten-network.com/us/en/veterans-affairs (xi) ACKNOWLEDGMENT OF AMENDMENTS: The offeror acknowledges receipt of amendments to the Solicitation numbered and dated as follows: AMENDMENT NO DATE Quote packages must include the following or responses will be considered non-responsive: Pricing Product information that supports the salient characteristics (if offering an or equal product) Certificate of manufacturer distribution authorization. Past performance reference supporting current success of proposed product within a VHA Medical Center (if offering an or equal product). (xii) Quotes are required to be received NO LATER THAN 10:00 AM EST, Tuesday, August 29, 2017. Quotes and supporting documentation must be e-mailed to Delene Kendrick at delene.kendrick@va.gov. (xiii) Direct your questions in writing to Delene Kendrick, Contracting Specialist at: delene.kendrick@va.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAWNYHCS528/VAWNYHCS528/VA24217Q1087/listing.html)
 
Document(s)
Attachment
 
File Name: VA242-17-Q-1087 VA242-17-Q-1087.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3754822&FileName=VA242-17-Q-1087-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3754822&FileName=VA242-17-Q-1087-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04645647-W 20170826/170824232621-389d0e35a6b4c77f84995081f602db9b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.