FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 01, 2017 FBO #5761
DOCUMENT

J -- Annual Preventive Maintenance and Defection Testing on Guldmann Patient Overhead Ceiling Lifts - Attachment

Notice Date
8/30/2017
 
Notice Type
Attachment
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101;Milwaukee; WI 53214-1476
 
ZIP Code
53214-1476
 
Solicitation Number
VA69D17Q1603
 
Response Due
9/6/2017
 
Archive Date
10/6/2017
 
Point of Contact
Naqikah Greenfield
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
3 STATEMENT OF WORK 1. DESCRIPTION OF SERVICES: The Contractor shall provide all labor, materials, weights, and equipment necessary to perform a complete and comprehensive annual preventive maintenance inspections and deflection testing on two-hundred ten (210) Guldmann patient overhead lifting systems located at the Captain James A. Lovell Federal Health Care Center (FHCC), 3001 Green Bay Road, North Chicago, IL 60064 as described in the Statement of Work. 2. SCOPE OF WORK: All testing and inspections shall meet and comply with Guldmann equipment manufacturer certification specifications and deflection testing as required in the Veterans Affairs Central Office (VACO) Patient Safety Alert AL14-07 (Attachment A) and the Corrective and Preventive Maintenance Checklist for Ceiling Mounted Patient Lifts (Attachment B). Requirements: All work shall be performed in accordance with OSHA and FHCC Safety guidelines. All work shall be performed as outlined in this Scope of Work and per the Department of Veterans Affairs specifications. Disposal of all items associated with this contract shall comply with the Resource Conservation and Recovery Act (EPA). All work performed shall be completed by personnel certified in services and repairs of Guldmann Ceiling Mounted Lifts. Prior to work taking place all certifications and credentials shall be submitted to the government for review and approval. The inspections shall be completed in the month of September each year. The Contractor shall submit a schedule for approval by the COR which outlines the work execution and time frames. All services shall be coordinated with the COR. Preventive Maintenance - Ceiling Mounted 1. The contractor shall provide annual preventive maintenance to a maximum of 210 overhead lift systems. The lift system consists of the overhead lift with accompanied components or accessories, the overhead lift charger, and the rail system (either traverse or fixed rail). The rail system includes any rails that are intended for use by that overhead lift system. The rail system is not defined only by breaks or gaps in the rails. 2. The stationary lifts are all Guldmann manufactured overhead lift systems, models follow: (120) GH2HD, (36) GH2, (26) GH3, (2) GH3+, (1) GH3+3501200110, (1) DH400, (2) Twin Strap, (21) 552099, & (1) 552062. 3. The lifts are located sporadically throughout the campus. Exact locations given upon award. 4. The preventive maintenance check list shall include but not be limited to the following list of tasks: Check for visible damage to the lift surfaces, finish, etc. Check the batteries for proper voltage per battery cell. Check that the rail system end stops are positioned properly and are tight. Check that all of the bolts are tightened on the entire overhead lift system. Check the movement of the lift carriage along the entire distance of the track. Check the movement of the traversing rail along the entire distance of the fixed rails. (traversing lift systems only) Check the emergency stop cord function. Check the hand control functions. Check the emergency lowering/raising (electrical) functions. Check the function of the squeeze protection limit switch. Check the entire lift strap for fraying, excessive wear or other visible damage. Inspect the sling bar bearings and safety latches. Check the charger functions to include: wall charging station, In-Rail Charging or Multi-Station Charging capacities. Check the type/model identification decal. Apply a Dated Inspection Sticker & a PM Sticker to each Operator upon completion of both 5. The contractor shall complete an annual Preventive Maintenance checklist provided by the COR for each lift based on the manufacturers' recommendations and the VA's requirements. A VA COR or designee must sign off as having witnessed the inspection. 6. A list of repairs required as a result of the inspection shall be provided with a cost proposal for the repair, after the annual service is complete. Costly parts needed that are not under this Scope of Work are items like internal Charger parts, Transformers, and T-Bars. Battery Replacement 1. The contractor shall provide, install and warranty the replacement batteries for each lift as needed during the annual inspection, as per price indicated on the schedule. 2. The contractor shall be responsible for the proper disposal of all replaced batteries and associated rubbish per current federal, state and local requirements. 3. The contractor shall also be responsible for proper storage of replacement and replaced batteries while the process is undergone. 4. The batteries must be of equal or greater quality than the batteries being replaced and also adhere to the manufacturer's recommendations for battery replacement. Load Testing Contractor shall provide a load test on each lift to the units' maximum load rated capacity and provide documentation of the success/failure of the test. The maximum load ratings are between 450lbs and up to 1100lbs. 3. HOURS OF OPERATION: Normal hours of coverage are Monday through Friday from 7:00 am to 3:30 pm CST, excluding holidays. All service/repairs will be performed during normal hours of coverage unless requested or approved by COR or designee. Holidays include: New Years' Day Labor Day Martin Luther King Day Columbus Day Presidents' Day Veterans' Day Memorial Day Thanksgiving Day Independence Day Christmas Day And any other day specifically designated as a national holiday by the President of the United States. 4. PLACE OF PERFORMANCE Captain James A. Lovell Federal Health Care Center (FHCC) 3001 Green Bay Road North Chicago, IL 60064-3048 5. PERIOD OF PERFORMANCE Base Year: September 11, 2017 through August 31, 2018 Option Year 1: September 1, 2018 through August 31, 2019 Option Year 2: September 1, 2019 through August 31, 2020 Option Year 3 September 1, 2020 through August 31, 2021 Option Year 4: September 1, 2021 through August 31, 2022 6. PERFORMANCE MONITORING: Various methods exist to monitor performance. The COR shall use the surveillance methods listed below in the performance monitoring of this contract. Direct Observation-(Can be performed periodically or through 100% surveillance.) Periodic Inspection-(Evaluates outcomes on a periodic basis. Inspections may be scheduled [Daily, Weekly, Monthly, Quarterly, or annually] or unscheduled, as required.) ACCEPTABLE PERFORMANCE The Government shall document positive performance. Any report may become a part of the supporting documentation for any contractual action. UNACCEPTABLE PERFORMANCE When unacceptable performance occurs, the COR shall inform the contractor. This will normally be in writing unless circumstances necessitate verbal communication. In any case the COR shall document the discussion and place it in the COR file. When the COR determines formal written communication is required, the COR shall prepare a Contract Discrepancy Report (CDR), and present it to the contractor's program manager. The contractor shall acknowledge receipt of the CDR in writing. The CDR will specify if the contractor is required to prepare a corrective action plan to document how the contractor shall correct the unacceptable performance and avoid a recurrence. The CDR will also state how long after receipt the contractor has to present this corrective action plan to the COR. The Government shall review the contractor's corrective action plan to determine acceptability. Any CDRs may become a part of the supporting documentation for any contractual action deemed necessary by the CO. 7. SECURITY REQUIRMENTS: Due to minimal interaction with patients and staff, the Credit & Accreditation (C&A) requirements do not apply and a Security Accreditation Package is not required. 8. HEALTH INSURANCE PORTABILITY AND ACCOUNTABILITY (HIPPA) ACT COMPLIANCE: Contractor must adhere to the provisions of Public Law 104-191, Health Insurance Portability and Accountability Act (HIPAA) of 1996 and the National Standards to Protect the Privacy and Security of Protected Health Information (PHI). As required by HIPAA, the Department of Health and Human Services (HHS) has promulgated rules governing the security and use and disclosure of protected health information by covered entities, including the Department of Veterans Affairs (VA). A Business Associate Agreement (BAA) is not required for this service.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/VA69D17Q1603/listing.html)
 
Document(s)
Attachment
 
File Name: VA69D-17-Q-1603 VA69D-17-Q-1603_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3767066&FileName=VA69D-17-Q-1603-003.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3767066&FileName=VA69D-17-Q-1603-003.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04654765-W 20170901/170830232639-ace8f35e5f4715e8d45114883e2bf6d6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.