Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 10, 2017 FBO #5770
MODIFICATION

Z -- Renovate HVAC Building 2007

Notice Date
9/8/2017
 
Notice Type
Modification/Amendment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Air Force, Air Education and Training Command, 502d Contracting Squadron, 1655 Selfridge Avenue, JBSA Lackland, Texas, 78236-5253, United States
 
ZIP Code
78236-5253
 
Solicitation Number
FA3016-17-R-0091
 
Response Due
9/7/2017 1:00:00 PM
 
Archive Date
9/28/2017
 
Point of Contact
edward chilson, Phone: 2109251841
 
E-Mail Address
edward.chilson@us.af.mil
(edward.chilson@us.af.mil)
 
Small Business Set-Aside
Woman Owned Small Business
 
Description
Question: Revised Section 01 11 00 paragraph 1.4.b states, "The Noise Criterion (NC) for the project area within the building is 35db. All new VAV and air side units shall be attenuated such that all new and interdicted ductwork and the balanced air flow shall meet the NC." Does the Government require maximum 35dB or NC35 for Room 119C? In our opinion, limiting the Contractor to straight 35dB across all frequencies is not feasible for this project. The following highlights the difference between "dB" levels and "NC" ratings: Noise Criterion (NC) were established in the U.S. for rating indoor noise like noise from air-conditioning equipment and similar. In Europe it is common to use the Noise Rating Curve - NR <http://www.engineeringtoolbox.com/nr-noise-rating-d_60.html>. The method consists of a set of criteria curves ranging 63 to 8000 Hz and a tangency rating procedure. The criteria curves defines the limits of octave band spectra that must not be exceeded to meet the occupants acceptance in the actual spaces. The NC rating can be determined by plotting the octave band levels for a given noise spectrum - the NC curves. The noise spectrum is specified as having a NC rating same as the lowest NC curve which is not exceeded by the spectrum. Answer: Noise level is acceptable 35db to 40db or acceptable levels as per office building industry standards.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LackAFBCS/FA3016-17-R-0091/listing.html)
 
Place of Performance
Address: Joint Base San Antonio Lackland, San Antonio, Texas, 78236, United States
Zip Code: 78236
 
Record
SN04668393-W 20170910/170908231522-c64c956e8714a6859bf8152ec2da4d99 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.