MODIFICATION
59 -- RECTIFIERS AND CHARGERS
- Notice Date
- 9/11/2017
- Notice Type
- Modification/Amendment
- Contracting Office
- Hwy 155, W/H B, Door 6, Industrial Area, Grand Coulee, WA 99133
- ZIP Code
- 99133
- Solicitation Number
- 0040330061
- Response Due
- 9/14/2017
- Archive Date
- 3/13/2018
- Point of Contact
- Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
- E-Mail Address
-
Clientservices@fedbid.com;
- Small Business Set-Aside
- Total Small Business
- Description
- AMENDMENT NOTICE: This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. The solicitation number is 0040330061 and is issued as an invitation for bids (IFB), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-95. The associated North American Industrial Classification System (NAICS) code for this procurement is 334413 with a small business size standard of 500.00 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2017-09-14 12:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be EMMETT, ID 83617 The DOI BOR Grand Coulee Power Office requires the following items, Brand Name or Equal, to the following: LI 001: DC COMPACT POWER SYSTEM - 19 RACK MOUNTABLE AND ONLY OCCUPY 6 RACK UNITS (6RU) HEIGHT; 48 VOLTS DC OPERATION WITH CURRENT SHELF OUTPUT OF 200 AMPERES MINIMUM; CAPABLE OF POSITIVE OR NEGATIVE GROUNDING; UNIVERSAL AC RANGE (90 264 VAC); EFFICIENCY OF 90% MINIMUM FOR 48 V OPERATION; TEMPERATURE RANGE (-40 DEGREE CELSIUS - +65 DEGREE CELSIUS); FRONT CHARACTER DISPLAY; BATTERY FLOAT VOLTAGE CONTROL WITH TEMPERATURE COMPENSATION; BATTERY BOOST AND BATTERY EQUALIZE CONTROL; SUPPORT INTERNAL AND EXTERNAL TEMPERATURE PROBES; BATTERY RECHARGE AND SYSTEM CURRENT LIMITS; MULTIPLE PROGRAMMABLE FORM C-RELAYS FOR VARIOUS ALARM/STATUS CONDITIONS; VARIOUS COMMUNICATIONS OPTIONS FOR REMOTE MONITOR/CONTROL INCLUDING MODEM AND ETHERNET HAVE A CONTROLLER CAPABLE OF ETHERNET ALONG WITH 4 MINIMUM AUXILLARY PORTS FOR TEMP PROBES; HAVE MULTIPLE DC BREAKERS MINIMUM OF 15 POSITIONS (BREAKERS RATED FROM 10 100 AMP CAPACITY); RECHARGE A 48 VDC @ 1296 AMP HOUR VALVE REGULATED BATTERY FROM 1.75 VPC TO FULL CAPACITY IN 8 HOURS. ELTEK/VALERE PART NO. 264678 MODEL NO. 4820N-19SA01 OR EQUAL., 6, EA; LI 002: CONTROLLER - MINIMUN OF 6 FORM-C RELAYS, AUDIBLE ALRM ALERTS, FOUR PERIPHERAL INPUT PORTS; 10/100 ETHERNET PORT CAPABLE OF SNMP TRAPS, HTTP, TELNET AND TL1; BATTERY EQUALIZE, BATTERY CURRENT LIMIT, RECTIFIER CURRENT LIMIT; OPERATING TEMPERATURE OF -40 DEGREE CELSIUS THRU +75 DEGREE CELSIUS; ALARM CABLE OUTPUT TO PROVIDE NORMALLY OPEN/NORMALLY CLOSED OUTPUT FROM ALARM RELAYS; MULTILEVEL LOGIN FOR BOTH LOCAL AND REMOTE OPERATIONS; EVENT LOG WITH A MINIMUM OF 250 EVENT STORAGE; FRONT ALARM INDICATIONS ALONG WITH AUDIBLE ALERTS FOR VARIOUS ALARMS; SYSTEM EVENT HISTORY CAPABLE OF REPORTING VIA IP ADDRESS VIA SYSLOG LOCAL INTERFACE WITH FUNCTIONS CONTROL AND DISPLAY/INDICATION. ELTEK/VALERE PART NO. BC2000-A01-10VC OR EQUAL. **MUST BE COMPATIBLE WITH ITEM IN LINE 001**, 6, EA; LI 003: RECTIFIER - HAVE CAPACITY OF OVER 50 AMPERES AT 48 VDC OPERATION; OPERATE ON INPUT VOLTAGE FROM 90 VAC 264 VAC; OPERATE UP TO 90% EFFIENCY; BE HOT SWAPPABLE; HAVE FRONT PANEL INDICATION; HAVE AC & DC FARIL ALARM ALONG WITH OVER-TEMPERATURE ALARM; OPERATE EITHER AS A STAND-ALONG UNIT OR WITH A SYSTEM CONTROLLER; ELTEK/VALERE PART NO V2500A-VC OR EQUAL. **MUST BE COMPATIBLE WITH ITEM IN LINE 001**, 30, EA; LI 004: CHASSIS WITH CLEI - BLANK V SERIES RECTIFIER CHASSIS WITH CLEI. ELTEK PART NO. VBLANK-VC OR EQUAL. **MUST BE COMPATIBLE WITH ITEM IN LINE 001**, 5, EA; LI 005: ALARM CABLE - 50 FOOT, #24 AWG SOLID ALARM CABLE. ELTEK/VALERE PART NO. CA210203105 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001, 12, EA; LI 006: LINE CORD - AC LINE CORD, 10 FOOT, 10 AWG, 1 POLE LUG TO UN TERMINATED. ELTEK/VALERE PART NO. LL1010-UU OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001**, 12, EA; LI 007: CIRCUIT BREAKER - CIRCUIT BREAKER, BULLET STYLE, SINGLE POLE, 100 A ELECTRO-MECHANICAL TRIP. ELTEK/VALERE PART NO. CBB100E OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001**, 12, EA; LI 008: CIRCUIT BREAKER - CIRCUIT BREAKER, BULLET STYLE, SINGLE POLE, 75 A ELECTRO-MECHANICAL TRIP. ELTEK/VALERE PART NO. CBB075E OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001**, 12, EA; LI 009: CIRCUIT BREAKER - CIRCUIT BREAKER, BULLET STYLE, SINGLE POLE, 50 A ELECTRO-MECHANICAL TRIP. ELTEK/VALERE PART NO. CBB050E OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001**, 12, EA; LI 010: CIRCUIT BREAKER - CIRCUIT BREAKER, BULLET STYLE, SINGLE POLE, 20 A ELECTRO-MECHANICAL TRIP. ELTEK/VALERE PART NO. CBB020E OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001**, 20, EA; LI 011: CIRCUIT BREAKER - CIRCUIT BREAKER, BULLET STYLE, SINGLE POLE, 10 A ELECTRO-MECHANICAL TRIP. ELTEK/VALERE PART NO. CBB010E OR EQUAL. **MUST BE COMPATIBLE WITH LINE 001**, 20, EA; LI 012: POWER DISTRIBUTION - POWER FUNCTION MANAGER INTEGRATES COMPONENTS WITH CONVERT ORDINARY POWER SUPPLIES INTO FULLY INTEGRATED AND MULTI FUNCTIONAL POWER SYSTEM; PROVIDES CONTROL, MONITORY, PARELLELING AND CIRCUIT BREAKER DISTRIBUTION OF 48 VDC, POSITIVE, NEGATIVE OR FLOATING GROUND POWER SOURCES A 500 AMP, HEAVY DUTY PARALLEL TIE POINT BUS ACCOMODATES INPUT FROM MULTIPLE/REDUNDANT RECTIFIERS. DIGITAL METER DISPLAYS SYSTEM BUS VOLTAGE, BATTERY VOLTAGE, TOTAL RECTIFIER AMPERAGE CONNECT/DISCONNECT FOLTAGE SET POINTS AND SYSTEM AMBIENT TEMPERATURE. INCLUDES STATUS LIGHTS, LOAD DISTRIBUTION CIRCUITS, LOW VOLTAGE BATTERY DISCONNECT WITH ALARM CONTRACTS. FUNCTIONS ARE COMBINES IN A COMPACT, RACK MOUNT HOUSING WHICH SERVES AS A MASTER DC POER MANAGEMENT AND DISTRIBUTION CENTER. THE PFM IS USED FOR INTEGRATION, CONTROL, MONITORING AND PROTECTION OF NUMEROUR DIFFERENT TYPES OF POWER SOURCES, SUCH AS AC-DC RECTIFIERS, REGULATED POWER SUPPLIES, DC-DC CONVERTERS AND BATTERY BANKS. 120 V AC INPUT VOLTAGE; 12-48V DC OUTPUT VOLTAGE RANGE; 12 V NOMINAL DC OUTPUT VOLTAGE; 500 A MAXIMUM CONTINUOUS AMPERAGE; 500 A MAXIMUM INTERMITTENT AMPERAGE; DIGITAL VOLTAGE/AMERAGE METER. NEWMAR PART NO. PFM-500 OR EQUAL., 6, EA; LI 013: FUSE DISTRIBUTION PANEL - DUAL 100 AMP BUS TO SUPPORT 10 FUSES PER BUS; 24 VDC/48 VDC INPUT; 100 A MAXIMUM CONTINUOUS AMPERAGE; 400 A MAXIMUM INTERMITTENT AMPERAGE. NEWMAR PART NO. FDP-1010 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 012**, 6, EA; LI 014: CIRCUIT BREAKER DISTRIBUTION PANEL - RACKMOUNT DISTRIBUTION PANEL HAS DUAL ISOLATED A AND B BUSES AT 450 AMPS THAT ACCEPT UP TO 10 BREAKERS EACH AND ENABLE REDUNDANT POWER, DUAL VOLTAGE AND/OR DUAL GROUND REFERENCE CONFIGURATION. PLUG IN CIRCUIT BREAKERS HAVE COMPRESSION POWER CONTACTS THAT INSERT SECURELY INTO SOCKETS RECESSED IN THE PANEL. BREAKER ALARM CONTACTS FEED AN OUTPUT CONNECTOR AT THE REAR OF THE PANEL FOR OPTIONAL REMOTE TRIPPED BREAKER ALARM/INDICATION. 48 VDC POSITIVE OR NEGATIVE GROUND INPUT/OUTPUT; 20 BREAKER CIRCUIT CAPACITY; 900 AMP CURRENT CAPACITY; 10 CIRCUIT MAXIMUM PER BUS; UP TO 50 DEGREE CELCIUS AMBIENT ENVIRONMENTAL TEMPERATURE RATING; ALARM INDICATOR IS A NORMALLY OPEN (N/O) CONFIURATION; 1 AMP @ 125 VAC, 5 AMPS, 5 AMPS @ 30 VDC FOR MAXIMUM POWER FOR ALARM CONTACTS. NEWMAR PART NO. DST-20A (UL) OR EQUAL. ** MUST BE COMPATIBLE WITH LINE 012**, 6, EA; LI 015: BREAKER - PLUG IN BREAKER 10 AMP WITH OPEN CIRCUIT ALARM CONTACTS. 48 V NOMINAL DC OUTPUT VOLTAGE; 10A MAXIMUM CONTINUOUS AMPERAGE; 10A MAXIMUM INTERMITTENT AMPERAGE. NEWMAR PART NO. PBA-10 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 012**, 14, EA; LI 016: BREAKER - PLUG IN BREAKER, 20 AMP WITH OPEN CIRCUIT ALARM CONTACTS; 48 V NOMINAL DC OUTPUT VOLTAGE; 20A MAXIMUM CONTINUOUS AMPERAGE; 20A MAXIMUM INTERMITTENT AMPERAGE. NEWMAR PART NO PBA-20 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 012**, 14, EA; LI 017: BREAKER - PLUG IN BREAKER, 30 AMP WITH OPEN CIRCUIT ALARM CONTACTS; 48 V NOMINAL DC OUTPUT VOLTAGE; 30A MAXIMUM CONTINUOUS AMPERAGE; 30A MAXIMUM INTERMITTENT AMPERAGE. NEWMAR PART NO. PBA-30 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 012**, 14, EA; LI 018: BREAKER - PLUG IN BREAKER, 50 AMP WITH OPEN CIRCUIT ALARM CONTACTS; 48V NOMINAL DC OUTPUT VOLTAGE; 50A MAXIMUM CONTINUOUS AMPERAGE; 50A MAXIMUM INTERMITTENT AMPERAGE. NEWMAR PART NO. PBA-50 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 012**, 14, EA; LI 019: BUS BAR ASSEMBLY - BUS BAR ASSEMBLY WITH MOUNTS ON REAR OF 19 OR 23 RACK SYSTEM. 48 V NOMINAL DC OUTPUT VOLTAGE; 800A MAXIMUM CONTINUOUS AMPERAGE; 400A MAXIMUM INTERMITTENT AMPERAGE. PAGE 4 OF 4NEWMAR PART NO. PBA-800 OR EQUAL. **MUST BE COMPATIBLE WITH LINE 012**, 7, EA; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, DOI BOR Grand Coulee Power Office intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. DOI BOR Grand Coulee Power Office is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids. All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com. Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process. Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. Bid MUST be good for 30 calendar days after close of Buy. Shipping must be free on board (FOB) destination CONUS (Continental U.S.), which means that the seller must deliver the goods on its conveyance at the destination specified by the buyer, and the seller is responsible for the cost of shipping and risk of loss prior to actual delivery at the specified destination. This solicitation requires registration with the System for Award Management (SAM) in order to be considered for award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. Registration must be "ACTIVE" at the time of award. SEE ATTACHED CLAUSES
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/9769598a0aaae41b1ce010343f12d046)
- Place of Performance
- Address: EMMETT, ID 83617
- Zip Code: 83617-9503
- Zip Code: 83617-9503
- Record
- SN04671105-W 20170913/170911232145-9769598a0aaae41b1ce010343f12d046 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)