Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 22, 2017 FBO #5782
SOLICITATION NOTICE

Y -- Fountain City Service Base Building

Notice Date
9/20/2017
 
Notice Type
Presolicitation
 
NAICS
236210 — Industrial Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, St. Paul, Attn: CEMVP-CT, 180 East Fifth Street, St. Paul, Minnesota, 55101-1678, United States
 
ZIP Code
55101-1678
 
Solicitation Number
W912ES17T0154
 
Archive Date
10/11/2017
 
Point of Contact
Jesse Onkka, Phone: 6512905444, Shamron Richardson, Phone: 651-290-5415
 
E-Mail Address
Jesse.L.Onkka@usace.army.mil, Shamron.J.Richardson@usace.army.mil
(Jesse.L.Onkka@usace.army.mil, Shamron.J.Richardson@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Scope of Work Provide to the Government all materials and labor for one three sided lean-to type building, the side of the building facing the river shall be left open. This building will be constructed and fastened to an existing concrete cistern. The concrete cistern dimensions are 47'3" L X 16' 11" W X 2'3" H wall thickness of approximately 8" +- ½", See attached photo. The roof and walls will extend beyond the cistern by 15'11" on the northwest (NW) side to allow for additional covered storage area. Please see attached drawing: Interested vendors are encouraged to verify all dimensions. Site visits are allowed and encouraged but are at the vendor's expense. Side/wall panels: Side panels shall match style and color of adjacent building and have a thickness 26 gauge of greater. Manufacture recommended fasteners shall be used. Fasteners shall be coated to match the wall panel color. Roof panels: Roof panels shall match color and style of adjacent building and have a thickness of 26 gauge or greater. Roof panels shall be designed to be removable in approximately 12' sections. Manufacture recommended fasteners shall be used. Fasteners shall be coated to match the roof color. Structural members: Structural members shall be of sufficient size and strength to meet all State and local building codes for this type building and can be attached directly to the existing concrete cistern. Supports which are located on the left hand side (NW) of the cistern shall be supported by contractor installed concrete footings. Footings shall comply with Federal and state (WI) building codes for this type of structure. Structural members shall be made of metal, made of square tubing least 4"x4" in dimension, and have a protective coating of paint to protect from corrosion. Location: Fountain City Service Base 431 North Shore DR Fountain City WI 54629 Point of Contact: Keith Graham, Plant and Facility Manager 651-290-5141 612-770-6455 cell
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA37/W912ES17T0154/listing.html)
 
Record
SN04686632-W 20170922/170920232147-296a6a5ea62d864ab6c6f6faff7ee3ba (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.