Y -- 671-18-1-5148-0002 Upgrade Fire Suppression System - Project 671-15-103 - Attachment

Notice Date
10/4/2017
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office, NCO 17;Central Texas Veterans HCS;2002 Scott Blvd;Temple TX 76504
 
ZIP Code
76504
 
Solicitation Number
36C25718B0001
 
Archive Date
1/11/2018
 
Point of Contact
Lu Ann Borth
 
E-Mail Address
luann.borth2@va.gov
(luann.borth2@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Pre-Solicitation Notice ONLY: The South Texas Veterans Health Care System (STVHCS), Network Contracting Office, NCO17 anticipates awarding a Firm-Fixed-Price construction contract to Upgrade Fire Suppression System; Project No. 671-15-103, located at the Audie L. Murphy Veterans Affairs Medical Center, 7400 Merton Minter, San Antonio, TX 78229. The method of procurement shall be an Invitation for Bid (IFB) in accordance with the procedures set forth in Parts 14 and 36 of the Federal Acquisition Regulation (FAR), with an anticipated approximate issue date of October 20, 2017 and a projected bid due date of November 28, 2017. Project consists of, but is not limited to; Contractor shall provide all necessary labor, materials, equipment, tooling, and supervision to perform all requirements of the resulting contract. The project includes, but is not limited to the following; contractor shall furnish all labor, materials, tooling, equipment, supervision to Upgrade Fire Suppression System located at the Audie L. Murphy VAMC. GENERAL REQUIREMENTS A site visit will be conducted at 7400 Merton Minter, Engineering Dept.-Ground Level, San Antonio, Texas 78229. 1.1 SAFETY REQUIREMENTS Refer to section 01 35 26, SAFETY REQUIREMENTS for safety and infection control requirements. 1.2 GENERAL INTENTION A. Contractor shall completely prepare site for building operations, including demolition and removal of existing work, and furnish labor and materials and perform work for FIRE SUPPRESSION SYSTEM CONSTRUCTION as required by drawings and specifications. B. Visits to the site by Bidders may be made only by appointment with the Medical Center Engineering Officer. C. Offices of Oculus Inc., as Architect-Engineers, will render certain technical services during construction. Such services shall be considered as advisory to the Government and shall not be construed as expressing or implying a contractual act of the Government without affirmations by Contracting Officer or his duly authorized representative. D. All employees of general contractor and subcontractors shall comply with VA security management program and obtain permission of the VA 11-01-15 01 00 00 -2 police, be identified by project and employer, and restricted from unauthorized access. 1.3 STATEMENT OF BID ITEM(S) A. ITEM I, Fire Suppression System Modifications Fire Pump: Work includes demolition of existing fire pump, concrete pads, control panel, fire piping and sprinklers. New work includes installation of a new fire pump, jockey pump control panels and related equipment; new piping, connectors, testing header; modification and addition of existing sprinklers and all labor, material, equipment and supervision to perform the required fire pump construction work on this project. ITEM II, Fire Suppression System Modifications Electrical Work: Work includes demolition of existing fire alarm controller, conduit and conductors and all labor, material, equipment and supervision to perform the required electrical construction work on this project. Project duration shall be 180 calendar days from issuance of the Notice to Proceed (NTP). This requirement is a competitive offer, Set Aside 100% for Service Disabled Veteran Owned Small Business (SDVOSB). The applicable NAICS code is 238220, $15.0 Mil. The magnitude of the construction estimated cost range: $250,000.00 - $500,000.00.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VACTHCS674/VACTHCS674/36C25718B0001/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25718B0001 36C25718B0001.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3835555&FileName=36C25718B0001-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3835555&FileName=36C25718B0001-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;South Texas Veterans HCS;7400 Merton Minter;San Antonio
Zip Code: TX
 
Record
SN04705592-W 20171006/171004230856-4ba71b652ca83e85a80e47edb5d31af0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.