Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 15, 2017 FBO #5805
SOURCES SOUGHT

20 -- 400 HZ Power Supply

Notice Date
10/13/2017
 
Notice Type
Sources Sought
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC), 2401 Hawkins Point Road, Building 31, Mail Stop 26, Baltimore, Maryland, 21226-5000, United States
 
ZIP Code
21226-5000
 
Solicitation Number
RFI400HZ
 
Archive Date
10/24/2017
 
Point of Contact
Florence M. Harwood, Phone: 410-762-6289
 
E-Mail Address
florence.m.harwood@uscg.mil
(florence.m.harwood@uscg.mil)
 
Small Business Set-Aside
N/A
 
Description
REQUEST FOR INFORMATION ONLY: The USCG Surface Forces Logistics Center is looking for sources capable of providing a developed product that meets or exceeds the salient characteristics provided below; required to ensure conformance and operational standards. THIS IS NOT A REQUEST FOR PRICING. THIS REQUEST IS FOR INFORMATIONAL PURPOSES ONLY! BRAND NAME OR EQUAL, FCX SYSTEMS FREQUENCY CONVERTER PFC010-V-40-FN, 12KVA SOLID STATE FREQUENCY CONVERTER IN 2 PIECE CABINET. FOR USE ON 210' MEDIUM ENDURANCE CUTTERS. PRODUCT SHALL MEET THE FOLLOWING SIZE LIMITATIONS: 68 INCHES X 45 INCHES X 48 INCHES TALL CAPABLE OF FITTING THROUGH A 24 INCH X 35 INCH HATCH. THIS CHARACTERISTIC MAY BE ACCOMPLISHED THROUGH DISASSEMBLY WITH STANDARD HAND TOOLS. CD6020 DIMENSIONS: TWO PIECES, HEIGHT 45IN, WIDTH 47IN, DEPTH 24IN. INPUT RATING: 440V, 60HZ, 3PH, AUTO PHASE LOCK FOR ABC OR CBA, OVERLOAD, SHORT CIRCUIT, OVER/UNDER VOLTAGE, PHASE LOSS, OVER-TEMP PROTECTION. OUTPUT RATING: 208/120V, 400HZ, 3PH, 12.5KVA,.8 POWER FACTOR, +- 1% VOLTAGE REGULATION, +- 0.5% VOLTAGE MODULATION, <- 0.050 MSEC VOLTAGE RECOVERY. VOLTAGE BALANCE: 1%@NOMINAL LOAD, 2%@25% UNBALANCE LOAD. PHASE SEPARATION: 120DEGREE +-1.0 DEGREE@NOMINAL LOAD. VOLTAGE TRIM: +- 15% NOMINAL OUTPUT VOLTAGE. CREST FACTOR: 1.414 +-0.05. HARMONIC THD: 2 TO 3% TYPICAL. LINE DROP: 0-10%. OVERLOAD HOLDING TIME: 110% 1 HR., 125% 5 MIN., 150% 20 SEC., 200% 10 SEC., 300% 6 SEC. COMBINATION 28VDC OUTPUT: 2 WIRE CONFIGURATION. +- 1% VOLTAGE REGULATION. ENVIRONMENTAL: OPERATING -32 C TO +50 C. -25 F TO +120 F. AIR STORAGE -40 C TO +71 C. -40 F TO +160 F. HUMIDITY: 10% TO 100% W/CONDENSATION. ALTITUDE: 0-3000 METERS W/OUT DE-RATING. WIND: <-145 KM/HR. AUDIBLE NOISE <- 68DB @ 2 METERS. INTERNAL AIRFLOW: SCR FAN 4.5IN X 100CFM. INVERTER COOLING FANS (2) 6IN X 255CFM. ELECTRONIC INTAKE FAN (2) 6IN X 255CFM. METERING & CONTROL 4X20 MATRIX VACUUM FLORESCENT OR LIQUID CRYSTAL DISPLAY: OUTPUT VOLTS VFD OR LCD. OUTPUT AMPS VFD OR LCD. OUTPUT FREQUENCY VFD OR LCD. ELAPSED TIME 6 DIGIT NON-RESETABLE. STATUS LAMP INDICATORS: POWER ON (1), CONVERTER ON (1), MODULE FAULT (1), INPUT VOLTAGE FAULT (1) OUTPUT VOLTAGE FAULT (1), OVERLOAD (1), 28VDC E/F PRESENT (1), OUTPUT #1 ON (1), OUTPUT #2 ON (1), ALARM SILENCED 91), MASTER MODE 91), SLAVE MODE (1), PARALLEL BYPASS (1). CONTROL BUTTONS: NUMERIC KEYPAD (16), START (1), STOP/RESET (1), Interested offerors shall submit their product information by 23 October 2017, 1:00 pm. Questions shall be submitted in writing to Ms. Florence Harwood; Florence.m.harwood@uscg.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGELC/RFI400HZ/listing.html)
 
Record
SN04713218-W 20171015/171013230833-03bcfeef9d18d2d5c5dbec300d2b52f9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.