SOURCES SOUGHT
Y -- replace the existing Area A Line C High-Temperature Hot Water (HTHW)/Steam heating system with gas-fired heating system
- Notice Date
- 10/17/2017
- Notice Type
- Sources Sought
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Louisville, Attn: CELRL-CT, PO Box 59, Louisville, Kentucky, 40201-0059, United States
- ZIP Code
- 40201-0059
- Solicitation Number
- W912QR-18-HTHWLINEC
- Archive Date
- 11/11/2017
- Point of Contact
- Marcel D. Hull, Phone: 5023156184, ,
- E-Mail Address
-
Marcel.D.Hull@usace.army.mil,
(Marcel.D.Hull@usace.army.mil, /div)
- Small Business Set-Aside
- N/A
- Description
- A market survey is being conducted to determine if there are a reasonable number of interested small business concerns to set this future project aside for them. If your firm is a Small Business, certified HUBZone, 8A, Woman-Owned Small Business or Service Disabled Veteran Owned Business and you are interested in this project please respond appropriately. The proposed project is a Design-Bid-Build to replace the existing Area A Line C High-Temperature Hot Water (HTHW)/Steam heating system with gas-fired heating systems serving Headquarters Air Force Materiel Command (HQ AFMC), Tenant, Visiting Officer Quarters (VOQ), and 88th Air Base Wing (88 ABW) F/10840 facilities at Wright-Patterson AFB, OH. The project's scope will require the contractor to remove/abandon all existing degraded central steam heat distribution systems and all associated equipment to HQ AFMC, Tenant, VOQ, and F/10840. Scope also requires the contractor to provide new gas-fired boilers with direct digital control (DDC) controls, new building/mechanical space and all utilities required to support gas boilers, new natural gas lines with smart meters and regulators, and all associated and required piping, valves, and equipment to connect to existing heating distribution systems within the facilities. The project will require the installation of up to ten (10) new boilers. The new boilers shall be as efficient as possible without major modification of the downstream system. Modify existing utilities to accommodate new boilers. Work includes the demolition of existing steam to hot water heat exchangers and low pressure steam reducing stations. Project will also include experience in ICD 705 construction, sensors/intrusion detection systems, Building Information Modeling software, and fire protection equipment. Contract duration is estimated at 730 calendar days. The estimated cost range is between $10M and $25M. NAICS code is 236220. All interested Small Businesses, certified HUBZONE, 8A, Woman-Owned Small Businesses or Service Disabled Veteran Owned Business contractors should respond to this survey by email on 13 October 2017 by 2 pm Eastern Standard Time. Responses should include: 1. Identification and verification of the company's small business status. 2. Contractor's Unique Identifier Number(s) (formerly DUNS number) and CAGE Code(s). 3. Documentation from the firm's bonding company showing current single and aggregate performance and payment bond limits. 4. Descriptions of Experience - Interested construction firms must provide no more than three (3) example projects with either greater than 90 percent completion or projects completed in the past five (5) years where the interested firm served as the prime contractor. Each project must include the name, title, project role, e-mail address, and telephone number of at least one reference. References may be used to verify project size, scope, dollar value, percentages and quality of performance. Example projects must be of similar size and scope. Example projects must be of similar size and scope. Demonstrated experience must include identification of self-performing 15% of the construction. a. Projects considered similar in scope to this project include but are not limited to: Construction of and/or renovation in areas requiring ICD 705 compliance. As part of the project description, the contractor should identify if the project utilized phasing of the work or simultaneous work at multiple facilities. b. Projects considered similar in size would include but are not limited to: Construction of and/or renovation in over 10,000 SF of space(s) that require ICD 705 compliance. The size of the project may be split across multiple buildings/facilities, so long as all of the effort is under one contract action (single stand-alone contract, one task order. Etc.) c. Based on the information above, for each project submitted, include: 1. Current percentage of construction complete and the date when it was or will be completed. 2. Scope of the project. 3. Size of the project. 4. The dollar value of the construction contract and whether it was design-bid build or design- build. 5. The percentage of work that was self-performed as project and/or construction management services or physical construction type work. 6. Identify the number of subcontractors by construction trade utilized for each project. Specifically identify any Mechanical subcontractors utilized and the scope of their effort. 7. Performance evaluation rating and name of the entity, company, or Government entity for which the work was performed with a reference's contact information to include name, phone number and email address. References may be used to verify project size, scope, dollar value, percentages and quality of performance. NOTE: Performance evaluations will not count against the total page count. 8. Current single and aggregate performance documentation from the firm's bonding company and payment bond limits. d. Small Businesses are reminded under FAR 52.219-14, Limitations on Subcontracting, they must perform at least 15% of the cost of the contract, not including the cost of materials, with the firm's own employees for general construction-type procurement. NOTE: Total submittal package shall be no longer than 8 pages. Please only include a narrative of the requested information; additional information will not be reviewed. Interested Offerors shall respond to this Sources Sought Synopsis no later than 27 October 2017 by 12:00 PM Eastern time. ALL RESPONSES MUST BE EMAILED to Marcel Hull, Contract Specialist, at: Marcel.D.Hull@usace.army.mil. This Sources Sought Synopsis is not to be construed as a commitment by the Government, nor will the Government pay for the information solicited. This is NOT a Request for Proposal. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market survey.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA27/W912QR-18-HTHWLINEC/listing.html)
- Place of Performance
- Address: Wight-Patterson Air Force Base, OH, United States
- Record
- SN04715268-W 20171019/171017230907-89874c041c96ee06da2fce7c88638e83 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |