Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 21, 2017 FBO #5811
DOCUMENT

65 -- 667-18-1-132-0002 - Reverse Osmosis Sys - VA256-18-AP-0177 - Attachment

Notice Date
10/19/2017
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
ALEXANDRIA VA HEALTH CARE SYSTEM;NETWORK CONTRACTING OFFICE 16;ALEXANDRIA VA HEALTH CARE SYSTEM;PO BOX 69004;ALEXANDRIA LA 71306-9004
 
ZIP Code
71306-9004
 
Solicitation Number
36C25618Q0073
 
Response Due
10/27/2017
 
Archive Date
12/26/2017
 
Point of Contact
FELICIA LOVELADY
 
E-Mail Address
A.LOVELADY@VA.GOV<br
 
Small Business Set-Aside
Veteran-Owned Small Business
 
Description
STATEMENT OF WORK (SOW) REVERSE OSMOSIS SYSTEM OVERTON BROOKS VAMC Background: A reverse osmosis system is needed in Sterile Processing Decontamination area for cleaning and rinsing of reusable medical equipment. The treated water will be plumbed to 2 Washer Disinfectors, 1 ultrasonic washer and 1 3 bay erogonomic sink. Water quality is pertinent in the cleaning of reusable medical equipment/ instruments. This equipment will meet the VA standard requirement for cleaning and rinsing of reusable medical equipment. Scope. The Reverse Osmosis System is to be plumbed to Steris CaviWave Ultrasonic Washers, Cavi--15W-E and Cavi-20WRD-E and Steris Washer Disinfector, Reliance SynergyWasher Disinfectors currently in use in Sterilie Processing Service Decontamination area. Installation of the system is required. No training is needed. Specifications/Characteristics: The Shreveport VAMC Sterile Processing Service is in need of 1 AmeriWater R03 with 185 gallon tank or equal brand Reverse Osmosis System with the following salient characteristics: Pre-carbon block filter Anti-scalant feed Controller with conductivity of feed and product water Disinfection cycle Storage tank with sealed lid and pump Deionizer polisher with monitor and alarm Low feed pressure system shutdown with alarm High conductivity alarm Storage tank empty pump shutdown One 1 ½ floor drain or sink Distribution pump output 30GPM @ 30 PSI No larger than 102 W x 72 D x 72 H Blend valve assembly 2200 GPD Must be compatible with Steris CaviWave Ultrasonic Washers, Cavi--15W-E and Cavi-20WRD-E and Steris Washer Disinfector, Reliance SynergyWasher Disinfectors currently in use in Sterilie Processing Service Delivery. 510 E. Stoner Overton Brooks VA Medical Center. Delivery is to be made 30 days after awarded. POC for delivery is Tiffany Love ext. 5544 and Susan Capers ext. 5472
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC502/AlVAMC502/36C25618Q0073/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25618Q0073 36C25618Q0073_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3859291&FileName=36C25618Q0073-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3859291&FileName=36C25618Q0073-000.docx

 
File Name: 36C25618Q0073 36C25618Q0073.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3859292&FileName=36C25618Q0073-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3859292&FileName=36C25618Q0073-001.docx

 
File Name: 36C25618Q0073 S15 Technical Verification Sheet.xlsx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3859293&FileName=36C25618Q0073-002.xlsx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3859293&FileName=36C25618Q0073-002.xlsx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: DEPARTMENT OF VETERANS AFFAIRS;SHREVEPORT VAMC;STERILE PROCESSING SERVICE;510 E STONER AVENUE;SHREVEPORT, LA
Zip Code: 71101
 
Record
SN04718255-W 20171021/171019231321-a5cc501a5fc51ce19de9fbe5cea7dcf6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.