Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 22, 2017 FBO #5812
SOURCES SOUGHT

68 -- Various Acid Vials Containing Various Acid Solutions

Notice Date
10/20/2017
 
Notice Type
Sources Sought
 
NAICS
325199 — All Other Basic Organic Chemical Manufacturing
 
Contracting Office
USGS OAG DENVER ACQUISITION BRANCH PO BOX 25046 204 DENVER FEDERAL CENTER DENVER CO 80225-0046 US
 
ZIP Code
00000
 
Solicitation Number
140G0218Q0006
 
Response Due
10/30/2017
 
Archive Date
11/14/2017
 
Point of Contact
Hayes, Lisa
 
E-Mail Address
ldwilliams@usgs.gov
(ldhayes@usgs.gov)
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. NO FORMAL SOLICITATION IS BEING REQUESTED UNDER THIS NOTICE. This Sources Sought Notice is for market research purposes to identify interested firms for the potential requirement detailed below. The North American Industry Classification System (NAICS) code is 325199 (All Other Basic Organic Chemical Manufacturing) and the size standard is 1,250 Employees. The Government will review the information requested in this announcement to determine the type of set-aside (if any) for this requirement, should it come to fruition. The U.S. Geological Survey (USGS), National Water Quality Laboratory (NWQL) has a requirement for acid vials for use in Water Resource Discipline (WRD) water sampling and testing programs. The USGS, WRD, and NWQL strive to maintain national consistency in all of the environmental samples collected by their personnel. The scientific analytical data from these samples is available and presented for use by other agencies and the public. It is extremely important that the supplies acquired hereunder be of high quality and will continue to provide consistency with the data that has been obtained, in some cases, for over a decade. Consistency in data is critical for the NWQL and USGS programs across the country for which the Lab does analysis, and only high quality items will allow for this. Unlike commercial labs, the NWQL, and the USGS programs they support, monitor trends in the data. Acid vials containing the following acid solutions must meet the following ¿brand name or equal ¿ specifications: 1.) Manufacturer: Thermo Fisher Scientific: Product: 2.0 mL, 7.5-7.7N Ultrex grade nitric acid solution, in a 4.5mL polypropylene (PP) copolymer screw cap vial (polyvials). The Ultrex nitric acid solution, packaged in a polypropylene screw cap vial, is to be used for preserving water samples prior to analysis. These polyvials will be used in conjunction with 250 mL acid rinsed natural high-density linear polyethylene bottles. Analyses are conducted after the water sample is taken with the preservative added. The components shall meet the following specifications: a. The screw cap vials shall be 4.5mL capacity and made of polypropylene (PP) copolymer. Vials are to be filled with 2.0 mL of 7.5-7.7N Ultrex nitric acid solution and then capped. The measurement tolerance shall be 2.0 mL delivery +/- 0.2 mL. The polyvials shall be bottom filled to prevent a defective seal. b. Each polyvial shall be clearly labeled with the mixture contents, lot number and the appropriate volume. The label shall be placed on the union of the cap and vial. A Material Safety Data Sheet (MSDS) or Safety Data Sheet (SDS) shall be provided. c. The vials shall be packaged in a Department of Transportation (DOT) approved styrofoam box which accommodates 24 vials. Each package shall be designed and sealed to guard against breakage and leakage. d. Contamination levels of the following metal constituents shall be less than the report levels described below when prepared to the equivalent of 1 vial volume added to 250mL of deionized water. ConstituentReport LevelUnit Ag0.005ug/L Al2.2ug/L As0.03ug/L B1.0ug/L Ba0.07ug/L Be0.006ug/L Cd0.016ug/L Co0.02ug/L Cr0.07ug/L Cu0.80ug/L Fe3.2ug/L Li0.22ug/L K0.004mg/L Mn0.13ug/L Mo0.014ug/L Ni0.09ug/L Pb0.025ug/L Se0.03ug/L Sb0.027ug/L Sr0.2ug/L V0.08ug/L Zn1.4ug/L Ca0.02mg/L Mg0.011mg/L Na0.06mg/L Silica0.018mg/L Tl0.01ug/L U0.004ug/L W0.01ug/L 2.) Manufacturer: Thermo Fisher Scientific: Product: 1 mL 4.5N sulfuric acid (Trace Metal grade) solution in a 4.5 mL polypropylene (PP) copolymer screw cap vial (polyvials). The 4.5N sulfuric acid (Trace Metal grade) solution vials will be used in conjunction with both natural and amber, high density linear polyethylene bottles and amber glass Boston Round bottles. These solutions shall be packaged in polypropylene screw cap vials and will be used for preserving water samples prior to analyses. Analyses are conducted after the water sample is taken with the preservative added. a. The polyvials shall be 4.5 mL capacity and made of polypropylene copolymer. These polyvials shall be filled with 1 mL 4.5N sulfuric acid (Trace Metal grade) solution and then capped. The measurement tolerance shall be 1 mL delivery +/-0.1 mL. The vials shall be bottom filled to prevent a defective seal. b. Each vial shall be clearly labeled with the mixture contents, lot number and the appropriate volume. The label shall be placed on the vial. A Material Safety Data Sheet (MSDS) or Safety Data Sheet (SDS) shall be provided. c. The polyvials shall be packed in a Department of Transportation (DOT) approved styrofoam box which accommodates 24 vials. Each package shall be designed and sealed to guard against breakage and leakage. The packaging process shall not contribute significant impurities above the specifications in the table in section d. d. Contamination levels of the following nutrient and carbon constituents shall be less than the report levels described below when prepared to the equivalent of one vial volume added to 125 mL deionized water. ConstituentsMethodReport Level Dissolved organic carbonHi-temp oxidation 0.23 mgL N-AmmoniaColorimetric 0.02 mg/L N-Ammonia + OrganicColorimetric 0.05 mg/L N-Nitrite + NitrateColorimetric 0.02 mg/L PhosphorusColorimetric 0.004 mg/L 3.) Manufacturer: Thermo Fisher Scientific: Product: 4 mL, 18N (1:1) sulfuric acid solution in an 8mL polypropylene (PP) screw cap vial (polyvials). The 18N sulfuric acid solution vials will be used in conjunction with natural high-density linear polyethylene bottles and amber glass Boston Round bottles. These solutions shall be packaged in polypropylene vials that will be used for preserving water samples prior to analyses. Analyses are conducted after the water sample is taken and with the preservative added. a. The polyvials shall be 8 mL capacity and made of plastic. These polyvials shall be filled with 4 mL 18N (1:1) sulfuric acid solution and then capped. The measurement tolerance shall be 4 mL delivery +/- 0.1 mL. The vials shall be bottom filled to prevent a defective seal. b. Each vial shall be clearly labeled with the mixture contents, lot number and the appropriate volume. A Material Safety Data Sheet (MSDS) shall also be provided. c. The polyvials shall be packed in a Department of Transportation (DOT) approved styrofoam box which accommodates 24 vials. Each package shall be designed and sealed to guard against breakage and leakage. The packaging process shall not contribute significant impurities above the specifications in the table in section d. d. Contamination levels of Oil & Grease and Total Petroleum Hydrocarbons (TPH) shall be less than the report levels described below when prepared to the equivalent of one vial volume added to 1000mL deionized water. ElementMethodReporting Level Oil & GreaseGravimetric5 mg/L TPHGravimetric25 ug/L 4.) Manufacturer: Thermo Fisher Scientific: Product: 2 mL, 18N (1:1) sulfuric acid solution in a 4.5mL polypropylene (PP) copolymer screw cap vial (polyvials). The 18N sulfuric acid solution vials will be used in conjunction with natural high-density linear polyethylene bottles and amber glass Boston Round bottles. These solutions shall be packaged in polypropylene screw cap vials that will be used for preserving water samples prior to analyses. Analyses are conducted after the water sample is taken with the preservative added. a. The screw cap vials for SVCS-2-1Q must be 4.5mL capacity and made of polypropylene copolymer. These polyvials shall be filled and then capped. The measurement tolerance shall be 2mL delivery +/-.1mL. The polyvials shall be bottom filled to prevent a defective seal. b. Each polyvial shall be clearly labeled with the mixture contents, lot number and the appropriate volume. A Material Safety Data Sheet (MSDS) shall also be provided. c. The polyvials shall be packed in a Department of Transportation (DOT) approved styrofoam box and accommodate 24 vials. Each package shall be designed and sealed to guard against breakage and leakage. The packaging process shall not contribute significant impurities above the specifications in the table in section d. d. Contamination levels of the following Chemical Oxygen Demand (COD) and Phenol constituents shall be less than the report levels described below when prepared to the equivalent of one vial added to 500mL deionized water for phenols and one vial added to 125 mL deionized water for COD. ConstituentsMethodReporting Level CODColorimetric10.0 mg/L PhenolColorimetric0.007 mg/L 5.) Manufacturer: Thermo Fisher Scientific: Product: 2 mL, 6N (1:1) Omni Trace Hydrochloric acid solution in a 4.5 mL polypropylene (PP) copolymer screw cap vial (polyvials). The 6N Omni Trace Hydrochloric acid solution vials will be used in conjunction with clear glass Boston Round bottles. These solutions shall be packaged in polypropylene (PP) screw cap vials and will be used for preserving water samples prior to analyses. Analyses are conducted after the water sample is taken and with the preservative added. a. The polyvials shall be 4.5 mL capacity and made of polypropylene copolymer. These polyvials shall be filled with 2 mL 6N (1:1) Omni Trace Hydrochloric acid solution and then capped. The measurement tolerance shall be 2 mL delivery +/- 0.1 mL. The vials shall be bottom filled to prevent a defective seal. b. Each vial shall be clearly labeled with the mixture contents, lot number and the appropriate volume. A Material Safety Data Sheet (MSDS) or Safety Data Sheet (SDS) shall also be provided. c. The polyvials shall be packed in a Department of Transportation (DOT) approved styrofoam box which accommodates 24 vials. Each package shall be designed and sealed to guard against breakage and leakage. The packaging process shall not contribute significant impurities above the specifications in the table in section d. d. Contamination levels for mercury shall be less than the report levels described below when prepared to the equivalent of one vial volume added to 200mL deionized water. ConstituentMethodReporting Level MercuryCVAF0.8 µg/L All business concerns who believe they can responsibly furnish the required items or its functional equivalent (based upon the criteria specified herein) shall submit the following information to the Contracting Officer. 1. The firm shall specify the product to be either the brand name or an equal product that meets the specifications listed above. 2. The firm shall provide two (2) most recent certificates of analysis (COAs) for each acid, which readily verifies that the products meets the technical specifications list above. 3. The firm shall specify that they are either a small business (8(a), HUBZone, SDVOSB, etc.) Or other than small business under the NAICS Code listed in the announcement. 4. The firm shall provide a point of contact name and e-mail information, and the firms Cage Code, and D&B Number. 5. Any other information that will prove the firm is capable of providing the brand name or equal products. NOTE: All information submitted in response to this announcement is voluntary - the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. Materials submitted to the Government for review will not be returned. Respondents will not be notified of the results of the evaluation. This is not a request for quotations. The Government does not intend to award a contract based on responses received under this announcement. In order to be responsive to this Notice, a firm must provide the appropriate documentation for consideration by October 30, 2017. Responses that do not comply with these procedures will not be considered. Inquiries will only be accepted by e-mail to Lisa Williams at ldwilliams@usgs.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOI/USGS/USGS/140G0218Q0006/listing.html)
 
Record
SN04718896-W 20171022/171020230813-60d2ba7286a77825354fb9b3b95eec51 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.