DOCUMENT
70 -- DX Workstation - Attachment
- Notice Date
- 11/1/2017
- Notice Type
- Attachment
- NAICS
- #334111
— Electronic Computer Manufacturing
- Contracting Office
- James Vercoe;Department of Veterans Affairs;VISN 22 Gilbert;777 E. Missouri, Suite 300;Phoenix AZ 85014
- ZIP Code
- 85014
- Solicitation Number
- 36C25818Q0045
- Response Due
- 11/15/2017
- Archive Date
- 1/14/2018
- Point of Contact
- James Vercoe
- Small Business Set-Aside
- N/A
- Description
- Statement of Work This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Please advise if you carry this product are a suitable or equal. Also, include company socio/Economic status and size. If you have any questions or concerns in reference to the Parts listing, please provide as well. EMAIL INFORMATION TO : James.Vercoe@VA.GOV Equipment being ordered: HP Z840 Workstation Transaction number: Please provide the following information clearly and precisely. THIS EQUIPMENT WILL CONTAIN PHI AFTER INSTALLATION, HOWEVER, VENDOR WILL NOT ACCESS PHI, AND INSTALLATION IS DONE IN-HOUSE. Description of what the equipment being requested is: The HP Z840 workstations are on the national Imaging approved list to run the VistARad application. These workstations will be utilized by staff Radiologists to view patient images and make medical diagnoses. These workstations will be used in conjunction with PowerScribe dictation workstations to read and annotate medical diagnoses. We are onboarding new radiologist staff and need new workstations to support staff in multiple reading locations. The monitors must be compatible with QAWEB. This application is utilized to calibrate to diagnostic specifications. Below are the required specifications: Screen technology TFT AM Color LCD Dual Domain IPS-Pro Aspect ratio (H:V) 16:10 Resolution Native 6MP (3280 x 2048) Configurable to 2 x 3MP+ (1640 X 2048) Configurable to 2 x 3MP (1536 X 2048) Pixel pitch 0.1995 mm Color imaging Yes Gray imaging Yes Color support 30 bit Viewing angle (H, V) 178 ° Uniform Luminance Technology (ULT) Yes Per Pixel Uniformity (PPU-LED) Yes (color PPU) Ambient Light Compensation (ALC) Yes Backlight Output Stabilization (BLOS) Yes (2x) I-Guard Yes Maximum luminance 720 cd/m ² DICOM calibrated luminance (ULT off) 500 cd/m ² Contrast ratio (dark reading room, typical) 1000:1 (panel typical) Response time (Tr + Tf) 18 ms Housing color Black / silver Landscape: 730 x 580~675 x 261 mm Dimensions w/o stand (W x H x D) Portrait: NA Landscape: 730 x 485 x 125 mm Dimensions packaged (W x H x D) 860 x 760 x 390 mm Recommended modalities CT, MR, US, DR, CR, NM, PET Certifications CE0120 (MDD 93/42/EEC; A1:2007/47/EC class IIb product), CE - 2004/108/EC, IEC 60950-1:2005 + A1:2009, EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011 + A2:2013, IEC 60601-1:2005, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A2:2010, CAN/CSA C22.2 No. 60601-1 (2008), EN 60601-1:2006 + A11:2011, EN 60601-1-2:2007, CCC - GB9254-2008 + GB4943.1-2011 + GB17625.1-2012, KCC, VCCI, FCC class B, ICES-001 Level B, FDA 510(k), RoHS Optional accessories Graphics board QA software MediCal QAWeb Who is the COR of the equipment: Steave Kantarowski, x6341 This is new PACS (image interpretation) workstations for radiologists that will contain PHI. 6500.6/Appendix A/Item 6 The Certification and Accreditation requirements do not apply and a Security Accreditation Package is not required. 6500.6/Appendix A/Item 7 The device/service will not be storing/collection any data released outside the VA. There is no sensitive information to protect.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/36C25818Q0045/listing.html)
- Document(s)
- Attachment
- File Name: 36C25818Q0045 36C25818Q0045.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3884395&FileName=36C25818Q0045-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3884395&FileName=36C25818Q0045-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25818Q0045 36C25818Q0045.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3884395&FileName=36C25818Q0045-000.docx)
- Place of Performance
- Address: Radiology Service;Phoenix VAMC;650 E Indian School Rd;Phoenix AZ
- Zip Code: 85012
- Zip Code: 85012
- Record
- SN04728892-W 20171103/171101231119-1ef56558395e0a4f6b8bf20853efe707 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |