Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF NOVEMBER 09, 2017 FBO #5830
SOLICITATION NOTICE

20 -- CGC SAGINAW A/C CONDENSER - FAR CLAUSES

Notice Date
11/7/2017
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC), 2401 Hawkins Point Road, Building 31, Mail Stop 26, Baltimore, Maryland, 21226-5000, United States
 
ZIP Code
21226-5000
 
Solicitation Number
70Z085-18-Q-P45350
 
Archive Date
12/6/2017
 
Point of Contact
Mayra C. Centurion, Phone: 5106375987
 
E-Mail Address
mayra.c.centurion@uscg.mil
(mayra.c.centurion@uscg.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
FAR CLAUSES U.S. COAST GUARD IS SOLICITING QUOTES FOR THE FOLLOWING: TECHNICAL SERVICES FOR INCINERATOR REPAIR ONBOARD THE USCGC SAGINAW 1. Background. This requirement is for the replacement of both A/C condensers. Its an 8 TON WATER CHILLER & RHEEN DAE - F3243, the condensers that they will be installing are: PT# MSE750Z model MSE750 CRN OH11802.5 2. Scope. The scope of this work is on the USCGC SANINAW and consists of replacing BOTH A/C condensers. 3. Objective. The objective of this requirement is to dissemble and replace both ships A/C consdensors. 4. Tasks. The contractor shall provide onboard engineering services to replace the front main oil seal include but are not limited to: 4.1. Recover refrigerant from both a/c circuits on SAGINAW. 4.2. Disconnect and remove two condensers from a/c skid in aft machinery space. 4.3. Replace with furnished condensers and put them in location where old condensers were removed. 4.4. Supply and install copper refrigerant pipe and fittings to connect both new a/c condensers to their respective refrigerant lines, where they were cut for condenser removal and install. 4.5. Remove old, and supply and install new filter drier in each a/c refrigerant circuit. 4.6. Pressurize and check a/c compressor skid for refrigerant leaks. 4.7. Put recovered refrigerant back into a/c system, energize and test system for proper operation. 5. Delivery. Contractor shall provide a final report within 3 days of contract period of performance. 6. Government furnished property. 02 A/C condensors. 7. Security Requirement. Base access is required. Vendor shall have a valid driver's license and show identification. A CG representative from the cutter will sponsor and escort vendor to the cutter. 8. Place of performance- CG SANINAW Home Prot 1500 15th St. Mobile, AL. 9. Period of performance-04DEC17-08DEC17.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGELC/70Z085-18-Q-P45350/listing.html)
 
Place of Performance
Address: CGC SAGINAW, SOUTH BROAD ST, Alabama, 36615, United States
Zip Code: 36615
 
Record
SN04733403-W 20171109/171107231014-065f423f1a6b74c21e75c94ffff1d265 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.