Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF NOVEMBER 18, 2017 FBO #5839
DOCUMENT

Z -- SOURCES SOUGHT NOTICE FOR MEDICAL HOME PORT RENOVATION, BUILDGING H-100 (PRIMARY CARE CLINIC), NAS CORPUS CHRISTI, TX - Attachment

Notice Date
11/16/2017
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
N69450 NAVFAC Southeast, Southeast Bldg. 903 Building 903 P. O. Box 30 NAS Jacksonville Jacksonville, FL
 
Solicitation Number
N6945018R0804
 
Response Due
12/19/2017
 
Archive Date
7/31/2018
 
Point of Contact
Barbara Czinder at (904) 542-6834 or Barbara.czinder@navy.mil
 
E-Mail Address
sources sought POC
(Barbara.Czinder@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
SOURCES SOUGHT NOTICE FOR MEDICAL HOME PORT RENOVATION, BUILDGING H-100 (PRIMARY CARE CLINIC), NAS CORPUS CHRISTI, TX Notice Type: Sources Sought Source Sought No: N69450-18-R-0804 Solicitation No: TBD Date: 16 NOVEMBER 2017 Response Date: 19 DECEMBER 2017 Classification Code: Z “ Maintenance, Repair or Alteration to Real Property NAICS Code: 236220 Commercial and Institutional Building Construction This is NOT a solicitation announcement and there are no plans/specifications/drawings or bid package available for this project. This is a Sources Sought Synopsis announcement only. This synopsis is a market research tool being utilized for information to be used for preliminary planning purposes. The information received will be used within NAVFAC Southeast to facilitate the decision making process. It does not constitute a solicitation (Request for Proposal or Request for Quotations) or a promise to issue a solicitation in the future. NAVFAC Southeast is looking for responses from interested Prime Contractors. We are not seeking responses from firms interested in subcontracting opportunities. This is a survey of the market of potential U.S. Small Business Administration (SBA) certified 8(a), SBA Certified HUB Zone, Service Disabled Veteran-Owned Small Businesses (SDVOSB), Women Owned Small Business (WOSB), and Small Businesses (SB). Based upon this survey a decision will be made whether to issue the proposed solicitation for the types of firms indicated above or to issue as full and open competition (unrestricted). This notice DOES NOT constitute a Request for Proposal/Solicitation, Request for Quote, or Invitation for Bid and there ARE NO plans or specifications for this notice. The intent of this notice is to identify potential offerors. It is not to be construed as a commitment of the Government for any purposes other than market research and is not restricted to a particular acquisition approach. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. Respondents will not be notified of the evaluation and any information submitted by respondents to this notice is strictly voluntary. If a solicitation is issued the solicitation number WILL NOT be the number same as the source sought notice number. It is the potential offerors responsible to check the Navy Electronic Commerce Online (NECO) website (https://www.neco.navy.mil) and the Federal Business Opportunities website. NAVFAC Southeast is seeking qualified businesses with current relevant experience to perform the following as described below: Project Description: This project will completely renovate the first floor clinic (~42,000 SF) to accommodate the Medical Home Port model of operations. The existing facility is five stories in height. A.Selective demolition of first floor walls, ceilings, and floor finishes. a.The facility will remain in full operation the duration of construction. b.Construction phasing planning shall not require clinic departments to relocate more than once. c.Temporary trailers will be leased by the Contractor and located on-site to allow the clinic to continue operations during construction. Utility connections to these trailers will also be required. B.Remediate asbestos wallboard, pipe insulation, and caulking throughout the renovation areas of the first floor and basement. C.Erect new partition walls doors, pass-windows, counters and cabinets, and related interior features in accordance with UFC 4-510 -01. D.Upgrade the interior directional signage will be throughout the entire first floor. E.Install a new vapor barrier to first floor exterior existing pre-cast panels. F.Install a new 300-Ton cooling tower and a new centrifugal condensate pump is to meet the condenser water requirements and to meet the chilled water set point. G.Remove existing AHU-I and install two new air handlers in a relocated mechanical room in full compliance with UFC 4-510 -01. a.Install a completely ducted return air system and convert existing CAV units to Variable Air Volume (VAV) units by providing Variable Frequency Drives (VFD) throughout the entire first floor. b.Install new Direct Digital Controls (DOC) for all new and modified mechanical equipment. i.Control components and accessories shall be compatible with the existing DDC system. ii.Update DDC system graphics concurrent with equipment modification and replacement. iii.Provide software updates concurrent with equipment replacement and modification for this and future projects. c.Relocate the outside air intake per UFC 4-510-01. d.Seal existing duct systems to remain and add balancing dampers. H.Remove the existing steam boilers and install two new complete closed-loop hot water systems each with high efficiency condensing boilers, storage tank, pumps, and DDC controls. One system will provide domestic hot water; the second system will provide heating hot water and HVAC reheat. Both systems serve the entire building. I.Install new insulated plumbing supply piping, waste piping, sinks, low flow fixtures, and rainwater drainage piping. J.Install new 500KVA transformer, secondary service, and 800A switchboard to support the renovated area. K.Remove and reinstall lighting fixtures and branch wiring for the renovated area. L.Install an electronic security system (ESS) to include intrusion detection, video surveillance, and access control in the renovated area. M.Modify the newly installed fire alarm and mass notification system throughout the renovated areas. N.Provide new copper/fiber optic communication data system throughout the renovated areas. Provide low voltage cable trays for all new copper/fiber optic cabling. O.Remove existing fire sprinkler heads and branch piping and install a new wet sprinkler system with quick response sprinkler heads to accommodate the clinics new arrangement. P.Renovated areas will receive new tile flooring and walls with gypsum ceilings in restrooms, VCT flooring in exam, lab, and pharmacy areas, carpeted floors in administrative areas, painted walls and acoustical ceilings elsewhere. Q.Equipment for this project includes; medical equipment, FF and E, communication systems, security and alarm systems, Audio-Visual (A/V). R.Replace the existing switchgear and 2,000kVA pad mounted utility transformer including any phasing to keep the facility operational during construction. S.Completely decommission the existing emergency generator and enclosure, the two existing propane tanks, and all associated controls, alarms, pads, conduit, and conductors. The emergency and egress lighting that is currently served by the emergency generator and that does not contain battery back-up will need to be modified to add battery ballasts or replaced to provide emergency and egress lighting to comply with NFPA 101. T.The 4 existing elevators do not currently have battery lowering and will need to be modified to add battery lowering once the existing emergency generator is decommissioned. Specific Project Requirements: A.The first floor and basement will be barrier free in accordance with DOD criteria and the DEPSECDEF Memorandum śAccess for People with Disabilities ť dated 10/31/2008. B.The first floor and basement shall include design for Anti-Terrorism Force Protection (ATFP) features and comply with ATFP regulations and physical security in accordance with Military Handbook 1024/1, Unified Facilities Criteria (UFC) 4-010-01 DoD Minimum Anti-Terrorism Standards for Buildings. C.Sustainable design features will be included in the design, development, and construction of the facility in compliance with Energy Policy Act of 2005, Executive Order 13423, and current Navy energy guidance. Third Party Certification (such as LEED) is NOT required for this project. NAICS Code: 236220 “ Commercial and Institutional Building Construction with the annual size standard of $36.5 million. Project Magnitude is $15 Million to $30 Million. Submission Package: Interested sources are invited to respond to this sources sought announcement by submitting the following information: 1.Contractor Information: Provide your firm ™s contact information, to include DUNS and Cage Code numbers. 2.Indicate if a solicitation is issued will your firm/company be submitting a proposal: _____ Yes ______No. 3.Type of Business: U.S. Small Business Administration (SBA) certified 8(a), SBA Certified HUB Zone, Service Disabled Veteran-Owned Small Businesses (SDVOSB), Women Owned Small Business (WOSB), and Small Businesses (SB). For more information on the definitions or requirements for these small business programs, refer to http://www.sba.gov. 4.Bond Capacity: Provide your surety ™s name, your maximum bonding capacity per individual project. Offeror ™s must be able to bond at higher end of the project magnitude range of $15 Million to $30Million. 5.Experience Submission Requirements: Submit a minimum of two (2) projects, one of which must be a Design-Bid-Build project to demonstrate experience in performing efforts of a similar size, scope and complexity to the project description above; and completed within the last seven (7) years. With an approximate completed value of $10 Million or greater. In addition, demonstrate that you have experience with phasing on a construction contract. Projects submitted shall also demonstrate the following: construction experience with hospitals/medical facilities/clinics. 6.Submissions shall contain the following items below (a “ g) for each project submitted for consideration. a.Include Contract Number, if applicable b.Indicate whether Prime contractor or Subcontractor c.Contract Value d.Completion Date e.Government/Agency point of contact and current telephone number. f.Project Description. Include a brief description, with sufficient detail, to determine whether this project is of a similar size and scope to the project description in this announcement; and, how the contract referenced relates to the project description herein. g.Indicate whether the project is Design-Build or Design-Bid-Build. Capability Statements consisting of appropriate documentation, literature, brochures will be accepted providing it contains ALL the information required above (items 1-5). Complete submission package shall not exceed 15 pages. This package shall be sent by email, no larger than 6 MB, to the following email address: Barbara.Czinder@navy.mil. OR via mail to Naval Facilities Engineering Command, Southeast Attn: Barbara Czinder, IPT-Gulf Coast P.O. Box 30 Jacksonville, FL 32212-0030 Or Naval Facilities Engineering Command, Southeast Attn: Barbara Czinder, IPT-Gulf Coast Bldg. 903, Yorktown Jacksonville, FL 32212-0030 Submissions must be received at the email addresses cited or via mail no later than 3:00 PM Eastern Time on 19 December 2017. LATE SUBMISSIONS WILL NOT BE ACCEPTED. Questions or comments regarding this notice may be addressed to email addresses above or by phone to Barbara Czinder at (904) 542-6834.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/1f2dd54bb2a9a26cc27d4b9ebe1e6dec)
 
Document(s)
Attachment
 
File Name: N6945018R0804_20171116_SOURCES_SGHT_H100_BUMED_Renovation.pdf (https://www.neco.navy.mil/synopsis_file/N6945018R0804_20171116_SOURCES_SGHT_H100_BUMED_Renovation.pdf)
Link: https://www.neco.navy.mil/synopsis_file/N6945018R0804_20171116_SOURCES_SGHT_H100_BUMED_Renovation.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04742875-W 20171118/171116231447-1f2dd54bb2a9a26cc27d4b9ebe1e6dec (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.