Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 03, 2018 FBO #5916
DOCUMENT

65 -- CRC-55 Dose Calibrator for Medical Imaging / Nuclear Medicine. - Attachment

Notice Date
2/1/2018
 
Notice Type
Attachment
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101;Milwaukee WI 53214-1476
 
ZIP Code
53214-1476
 
Solicitation Number
36C25218Q0508
 
Response Due
2/8/2018
 
Archive Date
2/23/2018
 
Point of Contact
Carl Weber
 
Small Business Set-Aside
N/A
 
Description
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and/or Small Businesses, including VIP-Verified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective contractors relative to the North American Industry Classification System (NAICS) Code 334519 (Other Measuring and Controlling Device Manufacturing). A CRC-55TR Dose Calibrator (Model 5130-3234) is known to meet the Government s needs. The Government is requesting that Other Than Small Businesses and Small Businesses, including VIP-Verified VOSB or SDVOSB sources respond if it can provide the following Brand Name OR Equal: CLIN Item Description Qty Unit 0001 5130-3234 CRC-55TR Dose Calibrator 1 EA 0002 0960-0183 Prog, Disk, 55T Comm, 1.0 for CRC-55TR 1 EA 0003 7300-2004 Liner, well, STD chamber 1 EA 0004 7300-2005 Vial/syringe dipper, STS chamber 1 EA 0005 7900-0353 Screen protector, touchscreen 1 EA 0006 5430-0100 Printer, Epson, Ticket/slip 1 EA 0007 7120-1240 Ticket, CRC-PC & 15R, Case/1500 CRP-200C dose and label tickets (1500/Case) for Epson ticket printer 1 EA Salient Characteristics for CRC-55TR Dose Calibrator (Model 5130-3234) Ionization Chamber: Thin wall, deep well, high pressure Dimensions: 26 cm (10") deep x 6 cm (2.4") dia (to meet pre-existing accessories) Measurement Range: Auto Ranging, up to 250 GBq (6 Ci), max. Resolution:.001 MBq (.01 µCi), max. Display Screen: Direct reading in Bq or Ci; Bq/Ci Reading: User selectable or fixed; Values Displayed: Nuclide name (Atomic symbol, Mass number), calibration number Electrometer: Accuracy: Better than ± 2%; Linearity: Within ± 2%; Response Time: Within 2 sec., 4 to 16 sec. for very low activity samples (user selectable average period) Repeatability of Measurement: Within ± 1% within 24 hours, during which time the calibrator is on all the time. Tests: Diagnostics: Full test of program, system memories; Quarterly: Daily, Accuracy and Linearity; Daily: Auto Zero, Auto Background Adjust, Data Check, Accuracy and Constancy Nuclear Data: Setting Keys: 8 Pre-set, 5 User; Calibration Key: Wide range of radiopharmaceutical nuclides; System Memory: Over 80 nuclides (w/cal number and half-life); A pre-set key measures up to 2.0 Ci (74.0 GBq) of F-18 Standard Source Data: System Memory: Co-57, Co-60, Ba-133, Cs-137 Standard Sources Molybdenum-99 Assay: Methods: Measured Values: Mo-99 elution, Tc-99m, Tc-99m/Mo-99 Ratio PC Port: Interface: Rs-232C Protocol & USB; Compatibility: Nuclear Medicine Information Systems (NMIS) Printing Options: Full size test reports. Measured results on tickets. Power Requirements: 100-240 VAC (50/60Hz) 90 MA. Interested Other Than Small Businesses and Small Businesses including VIP-Verified VOSBs and SDVOSBs are required to submit an e-mail delineating: Qualifications, capabilities, and experience for providing this product; Business size/Socioeconomic status; If the product is on the Federal Supply Schedule or the Open Market; and Memo or correspondence which authorizes distributor to distribute the manufacturer s products. This is not a Request for Proposal/Quote or an announcement of a solicitation and no solicitation package exists at this time. Responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration. The applicable North American Industry Classification System (NAICS) Code for this requirement is 334519 and the small business size standard is 500 employees. Responses should be submitted by e-mail to Carl Weber at carl.weber3@va.gov. The information requested must be received no later than close of business (4:30 p.m.) Central Standard Time on Thursday, February 08, 2018. Subject line shall reference Sources Sought announcement number 36C25218Q0508 from FBO.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/36C25218Q0508/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25218Q0508 36C25218Q0508.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4057461&FileName=36C25218Q0508-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4057461&FileName=36C25218Q0508-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04807608-W 20180203/180201231945-6a9d84f6a52fe0a038d115a577979658 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.