DOCUMENT
65 -- IV Fluid Warming Cabinet - Attachment
- Notice Date
- 6/1/2018
- Notice Type
- Attachment
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- VA NJ HCS East Orange NJ;Attn: Receiving Warehouse B;Level Bldg. 1 (ref PO number);385 Tremont Avenue;East Orange, NJ 07018
- ZIP Code
- 07018
- Solicitation Number
- 36C24218N2342
- Response Due
- 6/7/2018
- Archive Date
- 7/7/2018
- Point of Contact
- John M. Norway, Contract Specialist
- E-Mail Address
-
orway@va.gov<br
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- Page 1 of 1 Equipment Statement of Work (SOW) 1. Background: Surgical Service Anesthesia Section at VA New Jersey Healthcare System is requesting the y replacement of existing old, non-functional IV fluid warming cabinet in the OR area. The old unit can no longer be repaired and has reached end-of-service. 2. Objectives: To obtain reliable and functioning IV Fluid Warming for patient use in the Operating Rooms. This is for a commercially available medical equipment under a firm-fixed price contract. 3. Period of Performance: Vendor will deliver equipment on or before 30 days after receipt of order. 4. Place of Performance / Place of Delivery: VA NJ HCS East Orange NJ Equipment must be delivered to ATTN: Receiving Warehouse B-Level Bldg 1 (ref po number), VA Medical Center, 385 Tremont Ave, East Orange, NJ 07018. Receiving hours: Mon-Fri (excluding Federal Holidays) 8:30AM 3:30PM. Receiving desk phone (973) 676-1000 X 1293. 5. Requirements Quantity (1) each deluxe fluid warmer, 4 digit LED display, window doors, control lock programming and auto time programming, overall size: 251/4 W x 35 D x 41 H, compartment size: 7.7 cu ft, 1815/16 W x 261/2 D x 2615/16 H Features/Specs Electro-thermal Radiant Heat Technology Safety coated interior Fully insulated 125 VAC No lint traps Heavy duty hardware 4-digit LED display Designed specifically for the warming of irrigation and intravenous fluids Irrigation temperature adjusted from: 98 °F to 150 °F (37 °C to 65.5 °C) Intravenous temperature range: 98 °F to 104 °F (37 °C to 40 °C) Safety override feature prevents overheating Lockout feature Optional left hand door swing available 5 Casters Three epoxy-coated baskets with a max capacity of 24 liters per basket Individual temperature controls for irrigation fluids and intravenous fluids allow for precise temp settings for the proper fluid type Warranty: One (1) year Manuals: (2) Operator s and (2) Service at NO CHARGE FOB: Destination 6. Security Not required for warming cabinets.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/36C24218N2342/listing.html)
- Document(s)
- Attachment
- File Name: V797D-30207 36C24218N2342 V797D-30207 36C24218N2342_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4351554&FileName=V797D-30207-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4351554&FileName=V797D-30207-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: V797D-30207 36C24218N2342 V797D-30207 36C24218N2342_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4351554&FileName=V797D-30207-001.docx)
- Record
- SN04941675-W 20180603/180601231039-75bd26601a34284eb8a12636e73a267e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |