- Description
- The Regional Health Contracting Office - Atlantic (RHCO-A), Womack Army Medical Center, Ft Bragg, North Carolina intends to solicit the below products as Brand Name or Equal requirement. 1 each Phototherapy System: Consisting of: 1 Each BiliSoft LED Phototherapy System, Small Pad (English, US Plug) M1091160 7 Each BiliSoft LED Phototherapy System, large Pad (English, US Plug) M1091990 1 Each BiliBlanket Light Meter 6600-0198-900 1 Each Pad Covers, Disposable Small Box of 50, Bilisoft CF-M1093120 1 Each Pad Covers, Disposable Large Box of 50, Bilisoft CF-M1093121 Equipment will be new; no used, rebuilt or refurbished equipment will be acceptable. Warranty- equipment will be free from defects on acceptance of equipment. Free from defects in material and workmanship under normal use and service for 1 year. Warranty covers parts and labor. Equipment shall be in compliance with the 2017 Neonatal Resuscitation Program (NRP) standards. No telephonic request will be honored or returned. This is not a request for quotes at this time; however, if your company has information or these products, please send your capabilities statement for review. All responses will be received no later than 30 June 2018 at 11:00 AM EST. For more information please contact Ms. Mary A. Mitchell- Martin at mary.a.mitchellmartin.civ@mail.mil *** See specifications below*** BiliSoft LED Phototherapy System specifications Electrical specifications Input: • 1.5 A @ 100 - 240 V,~ 50/60 Hz Fuses: • T3.15 A @ 250 V,~ slo-blo type (qty. 2) Leakage current: • < 300 μA @ 264 V~ Ground impedance: • < 0.1 ohm from ground pin of the power inlet module to any exposed metal surface Environmental operating conditions Ambient temperature: • +10°C to +35°C (50°F to 95°F) Humidity: • 10% to 90% RH non-condensing Atmospheric pressure: • 70 kPa to 106 kPa Storage requirements Temperature: • -40°C to +70°C (-40°F to 158°F) Humidity: • 0% to 100% RH noncondensing Atmospheric pressure: • 50 kPa to 106 kPa Performance specifications Spectral irradiance (bare fiberoptic pad):* • Large fiberoptic pad - 49 μW•cm-2•nm-1 (+/- 25%) 9-point check • Small fiberoptic pad - 70 μW•cm-2•nm-1 (+/- 25%) 6-point check Note: When the BiliSoft fiberoptic light pad is inserted into a BiliSoft pad cover or BiliSoft nest, the nominal spectral irradiance is 35 μW•cm-2•nm-1 (large pad) and 50 μW•cm-2•nm-1 (small pad). * Using an Ohmeda Medical BiliBlanket® Light Meter Wavelength: • 430-490 nm (peak 440-460 nm) LED module estimated life:† • Under continuous use, tested at room temperature, a typical LED module will run for approximately 8,000 to 10,000 hours before the light intensity drops 25% † The LED module life may vary when used in the actual clinical environment. Factors such as duty cycle and ambient temperature may impact the life of the LED module. Measure the irradiance of the BiliSoft System and replace the LED module when the system is below specifications. Sound level: • < 44 dB(A) at 1 meter X-ray: • X-ray compatible Physical specifications Light box (W x H x L): • 16.5 x 21 x 16.5 cm Light box weight (excluding fiberoptic pad): • < 2.5 kg Fiberoptic pad weight: • < 1.1 kg Fiberoptic light pad, small: • 15 x 30 cm (light-emitting area) Fiberoptic light pad, large: • 25 x 30 cm (light-emitting area) Fiberoptic cable length: • 137 ± 5 cm Regulatory standards IEC Type B equipment IEC Class 1 (continuous operation) FDA Class II Product certified to the following standards: • EN60601-1 • EN60601-1-2 • EN60601-2-50 • ISO 10993-5 • ISO 10993-10 • UL 60601-1 • CSA C22.2 No 601.1-M90 • IEC 60601-1-8 • BS EN 980 • 16CFR Part 1632.6 (for BiliSoft pad covers and BiliSoft nests)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA15/W91YTZ-18-Q-0030/listing.html)
- Record
- SN04948445-W 20180609/180607231211-851437d7d4ac804080baddd69c7f3249 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |