SOLICITATION NOTICE
28 -- LMA ISO-Phased Bus System Inspection & Testing
- Notice Date
- 6/18/2018
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Walla Walla, Attn: CENWW-CT, 201 North 3rd Avenue, Walla Walla, Washington, 99362-1876, United States
- ZIP Code
- 99362-1876
- Solicitation Number
- W912EF18Q0103
- Point of Contact
- LeAnne R. Walling, Phone: 5095277230
- E-Mail Address
-
leanne.r.walling@usace.army.mil
(leanne.r.walling@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Summary of Scope of Work: The Iso-Phase bus and enclosure systems shall receive a full assessment and a set of routine tests, defined in IEEE C37.23, as practical and applicable. The test requirement constitute a minimum and do not preclude the contractor from performing other standard tests. The non-continuous enclosure system is experiencing, in the area of the 1979 modification, a section of high heat and circulating currents on the bus enclosure and on adjacent bus supports. This section shall be thoroughly inspected and corrective actions defined. Electrical Scope of Work: Inspections A. The iso-phase bus and enclosure assessment shall be an inspection of both bus types from the generators to a demarcation point, below the weather exposed bus enclosures, that shall in-clude: a. All taped and/or gasketed covers, hatches, joints and sections. b. All standoff and through bushings. c. All connecting hardware and support structures. d. All bus enclosure bonding and grounding connections. e. All phase bus connections (welded and bolted). f. The iso-phase bus. g. The iso-phase enclosures h. Deviations from original designs i. The 1979 phase rotation bus modification Methods used to identify the condition assessment shall include but, are not limited to: a. Bore scoping of bus and enclosure. b. Visual inspection. c. High potential testing of bus. d. Documenting all areas needing corrective action shall be submitted in writing and documented on as-built iso-phase system project drawings. e. Contractor shall submit a list of all hardware and corrective actions required to restore bus and enclosure to optimal design function, per IEEE C37.23, Standard for Metal-Enclosed Bus. f. Submission of a complete final report, post inspection, shall include overall system condition assessment and inspection results, with recommended corrective actions.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF18Q0103/listing.html)
- Place of Performance
- Address: Lower Monumental Dam, 5520 Devils Canyon Rd, Kahlotus, Washington, 99335, United States
- Zip Code: 99335
- Zip Code: 99335
- Record
- SN04957871-W 20180620/180618230605-a512863c0f69cc95b48432adf01858bf (fbodaily.com)