Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 22, 2018 FBO #6055
DOCUMENT

Z -- SOURCES SOUGHT NOTICE FOR REPLACE FIRE PUMP BUILDING 3460 NAVAL AIR STATION PENSACOLA, FL - Attachment

Notice Date
6/20/2018
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
N69450 NAVFAC Southeast, Southeast Bldg. 903 Building 903 P. O. Box 30 NAS Jacksonville Jacksonville, FL
 
Solicitation Number
N6945018R0809
 
Response Due
6/29/2018
 
Archive Date
12/31/2018
 
Point of Contact
James Miller at 904-542-6812 or james.a.miller18@navy.mil AND Barbara Czinder at 904-542-6834 or Barbara.czinder@navy.mil
 
E-Mail Address
SSN POC
(Barbara.Czinder@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
SOURCES SOUGHT NOTICE FOR REPLACE FIRE PUMP BUILDING 3460 NAVAL AIR STATION PENSACOLA, FL Notice Type: Sources Sought Source Sought No: N69450-18-R-0809 Solicitation No: TBD Date: June 19, 2018 Response Date: July 19, 2018 Classification Code: Z “ Repair and Maintenance NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors This is NOT a solicitation announcement and there are no plans/specifications/drawings or bid package available for this project. This is a Sources Sought Synopsis announcement only. This synopsis is a market research tool being utilized for information to be used for preliminary planning purposes. The information received will be used within NAVFAC Southeast to facilitate the decision making process. It does not constitute a solicitation (Request for Proposal or Request for Quotations) or a promise to issue a solicitation in the future. NAVFAC Southeast is looking for responses from interested Prime Contractors. We are not seeking responses from firms interested in subcontracting opportunities. This is a survey of the market of potential U.S. Small Business Administration (SBA) certified 8(a), SBA Certified HUB Zone, Service Disabled Veteran-Owned Small Businesses (SDVOSB), Women Owned Small Business (WOSB), and Small Businesses (SB). Based upon this survey a decision will be made whether to issue the proposed solicitation for the types of firms indicated above or to issue as full and open competition (unrestricted). This notice DOES NOT constitute a Request for Proposal/Solicitation, Request for Quote, or Invitation for Bid and there ARE NO plans or specifications for this notice. The intent of this notice is to identify potential offerors. It is not to be construed as a commitment of the Government for any purposes other than market research and is not restricted to a particular acquisition approach. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. Respondents will not be notified of the evaluation and any information submitted by respondents to this notice is strictly voluntary. If a solicitation is issued the solicitation number WILL NOT be the number same as the source sought notice number. It is the potential offerors responsible to check the Navy Electronic Commerce Online (NECO) website (https://www.neco.navy.mil) and the Federal Business Opportunities website. NAVFAC Southeast is seeking qualified businesses with current relevant experience to perform the following as described below: Project Description: The scope of work shall include the removal of the existing out of service water pumps, associated piping, control panels, and electrical services. Rework of the existing automatic sprinkler system riser assembly and supply piping will be required to provide a new electric fire pump. Provide a new horizontal split case electric fire pump capable of support the existing automatic sprinkler systems in Building 3460. The fire pump shall be provided with new electrical service and emergency generator for reliability in the event of a power failure. Provide necessary site work for new generator and electrical service. Existing fire alarm system circuits shall be modified to monitor all aspects of the fire pump and associated equipment. NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors with the annual size standard of $15 million. Project Magnitude is $300,000 to $1 Million. Submission Package: Interested sources are invited to respond to this sources sought announcement by submitting the following information: 1.Contractor Information: Provide your firm ™s contact information, to include DUNS and Cage Code numbers. 2.Indicate if a solicitation is issued will your firm/company be submitting a proposal: _____ Yes ______No. 3.Type of Business: U.S. Small Business Administration (SBA) certified 8(a), SBA Certified HUB Zone, Service Disabled Veteran-Owned Small Businesses (SDVOSB), Women Owned Small Business (WOSB), and Small Businesses (SB). For more information on the definitions or requirements for these small business programs, refer to http://www.sba.gov. 4.Bond Capacity: Provide your surety ™s name, your maximum bonding capacity per individual project. Offeror ™s must be able to bond at the high end of the project magnitude range of $300,000 to $1Million. 5.Submit a minimum of two (2) Design-Build projects, to that demonstrate experience in which your firm SELF-performed the fire protection system installation efforts of a similar size, scope and complexity to the project description above; and completed within the last seven (7) years. With an approximate Fire Protection System scope value of $300,000 or greater. Each project submitted must demonstrate scope in fire pump system and fire suppression system water supply design and installation to be considered similar in scope and complexity. Projects must indicate fire protection scope of work was self-performed, work that was Sub-Contracted out (performed by a different firm) will not be considered. Submissions shall contain the following items below (a “ g) for each project submitted for consideration. a.Include Contract Number, if applicable b.Indicate whether Prime contractor or Subcontractor c.Contract Value d.Value of Fire Protection System scope e.Completion Date f.Government/Agency point of contact and current telephone number. g.Project Description. Include a brief description, with sufficient detail, to determine whether this project is of a similar size and scope to the project description in this announcement; and, how the contract referenced relates to the project description herein. h.Indicate whether the project is Design Build. Capability Statements consisting of appropriate documentation, literature, brochures will be accepted providing it contains ALL the information required above (items 1-5). Complete submission package shall not exceed 15 pages. This package shall be sent by email, no larger than 6 MB, to the following email addresses: james.a.milleer18@navy.mil and Barbara.czinder@navy.mil OR via mail to Naval Facilities Engineering Command, Southeast Attn: james.a.miller18@navy.mil, Gulf Coast P.O. Box 30 Jacksonville, FL 32212-0030 Or Naval Facilities Engineering Command, Southeast Attn: james.a.miller18@navy.mil, Gulf Coast Bldg. 903, Yorktown Jacksonville, FL 32212-0030 Submissions must be received at the email addresses cited or via mail no later than 3:00 PM Eastern Time on 29 June 2018. LATE SUBMISSIONS WILL NOT BE ACCEPTED. Questions or comments regarding this notice may be addressed to email addresses above or by phone to James Miller at (904) 542-6812
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/71c03d4bebad8acb8320996879ff5a30)
 
Document(s)
Attachment
 
File Name: N6945018R0809__Replace_Fire_Pump_B3460_NAS_Pensacola_FL_SSN.pdf (https://www.neco.navy.mil/synopsis_file/N6945018R0809__Replace_Fire_Pump_B3460_NAS_Pensacola_FL_SSN.pdf)
Link: https://www.neco.navy.mil/synopsis_file/N6945018R0809__Replace_Fire_Pump_B3460_NAS_Pensacola_FL_SSN.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04962206-W 20180622/180620231157-71c03d4bebad8acb8320996879ff5a30 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.