Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 23, 2018 FBO #6056
SOURCES SOUGHT

65 -- BioMerieux, Vitek and Supplies

Notice Date
6/21/2018
 
Notice Type
Sources Sought
 
NAICS
325413 — In-Vitro Diagnostic Substance Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Medical Command, REGIONAL HEALTH CONTRACT OFF CENTRAL, ATTN: MCAA GP L31 9V, 2539 GARDEN AVENUE, JBSA FT SAM HOUSTON, Texas, 78234-0000, United States
 
ZIP Code
78234-0000
 
Solicitation Number
W81K00-18-R-0015
 
Archive Date
7/11/2018
 
Point of Contact
Lisa D. Washington, Phone: 2102213216, Jamie Brunner, Phone: 2102213061
 
E-Mail Address
lisa.d.washington.mil@mail.mil, jamie.m.brunner.civ@mail.mil
(lisa.d.washington.mil@mail.mil, jamie.m.brunner.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a Sources Sought Notice announcement; market survey for information only, to be used for preliminary planning purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. Any requests for a solicitation in response to this notice will not be honored. Submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. The US Army Medical Command, Regional Health Contracting Office-Central, Fort Sam Houston Contracting is issuing this sources sought as a means of conducting market research to identify qualified sources prior to the release of any potential solicitation for the brand name or equal of the following: 1) BioMerieux, VITEK MS 2) BioMerieux, VITEK 2 3) Compatible Bacterial Identification Testing Supplies The salient characteristics are as follows: a. Must FDA Approved. b. Must interface with the government-owned BacT/Alert system at WBAMC, used to transfer results for a positive identification through the Mylsa for independent tracking. c. Must provide sample entry for both systems via utilization of Prep Stations. d. Must allow Pep Station software to enter both the ID and AST information, to include multiple Prep Stations to streamline workflow. e. Must utilize a unique algorithm and process to compare unknown isolates against a known database. f. Must accommodate up to 192 samples in one run. g. Must utilize disposable slides that are individually barcoded for traceability for FDA protocol. h. Must utilize an "Auto Quality" feature that ensures each sample that is analyzed has a set number of spectral profiles (100 profiles) in order to increase accuracy and reliability of the identification. i. Must provide Gram-negative, Gram-positive, Yeast and anaerobes identification cards single on-slide workflow per FDA submission. j. Must perform a dilution algorithm to test all antibiotics within the CLSI allowing reporting of results a Resistant for a number over the highest "true MIC" risking a change to diagnosis decisions by providers. k. Must be able to report based on the Pharmacy Algorithm for treatment options for providers. The contractor's capability statement shall prove their ability to offer brand name or equal supplies as listed above. It will be the offerors responsibility to clearly explain how their product meets the specifications listed above. Proprietary information, if any, should be minimized and MUST BE CLEARLY MARKED. Any interested vendor must provide documentation stating they can provide specified supplies. To aid the Government, please segregate proprietary information. Please be advised that all submissions become Government property and will not be returned. It is anticipated that the proposed this equipment will result in a Firm-Fixed Price contract. The proposed North American Industry Classification System (NAICS) Code is 325413, In-Vitro diagnostic Substance Manufacturing, FSC - 6515, Medical and Surgical Instruments, Equipment and Supplies, with a corresponding size standard of 1,250 employees. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES, PROCURED THROUGH FULL AND OPEN COMPETITION OR SOLE SOURCE. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested Offeror shall respond to this Sources Sought Notice no later than 26 June 2018 at 9:00 a.m., central. All responses under this Sources Sought Notice must be emailed to lisa.d.washington.mil@mail.com and jamie.m.brunner.civ@mail.mil. Telephonic inquires will not be honored. EMAIL IS THE PREFERRED METHOD.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA09/W81K00-18-R-0015/listing.html)
 
Place of Performance
Address: William Beaumont Army Medical Center (WBAMC), Fort Bliss, Texas, 79920, United States
Zip Code: 79920
 
Record
SN04963819-W 20180623/180621231253-f63a4111118b4d159772f97f24394e64 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.