Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 29, 2018 FBO #6062
DOCUMENT

Z -- Cable Pull and Accessories Installation Services for VA Medical Center Sheridan, WY, 82801 - Attachment

Notice Date
6/27/2018
 
Notice Type
Attachment
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19, Services 3;1011 Honor Heights Dr;Muskogee OK 74401
 
ZIP Code
74401
 
Solicitation Number
36C25918Q9607
 
Response Due
7/5/2018
 
Archive Date
10/3/2018
 
Point of Contact
Lance Davis
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Cable Pull and Accessories Installation Services VA Medical Center Sheridan WY 82801 BRIEF SCOPE OF WORK Project Scope The contractor shall provide all labor, personnel, equipment and test equipment, tools, supervision, parts, materials (to include all cable and any needed accessories and/or other items) necessary to provide cable and accessories installation, onsite for Communications Systems located at the Sheridan VAMC facility and as defined in this Statement of Work (SOW). Purpose: Install cabling and terminations for expanding Network Infrastructure to support device (video) integration in various locations throughout the medical facility. Background: The facility is bringing on line, via the information network, an information display system that will provide veterans with health information and facility events relevant to educating veterans and improving their well-being. The video displays are located in patient waiting areas of which there are 6 that require a network connection. Network Cable Specifications: All cabling installed to be Plenum rated CAT6. Cabling is to be terminated (punched down) per ANSII standards. On the display end of the cable run, wall plates are to be mounted, allowing a male CAT6 plug to connect to the network and the color to be white, off-white, or eggshell. Wiring above the overhead ceiling (grid) will be suspended so as not to lay directly upon ceiling tiles. Utilizing existing cable trays are recommended. Prior to performing any new fire wall penetrations, the Safety Officer requires the proper documentation (provided by the Safety Office) and that the contractor follow all NFPA standards for ensuring fire wall integrity. On the network side (switch) the terminated and labeled cable will be run to the switch plus a 3-meter maintenance loop added at the network switch equipment rack. All completed cables are to be tested to ensure continuity. All services for this contract must meet manufacturer performance and technical specifications, Federal Regulations, and other specifications that may apply such as National Electric Code (NEC), Life Safety Code (LSC), Joint Commission (JC), and VA Regulations, American National Standards Institute (ANSI), Electronic Industries Alliance (EIA)/ Telecommunications Industry Association (TIA), and Building Industry Consulting Service International (BICSI) Telecommunications Distribution Methods Manual (TDMM). VA has adopted the National Fire Codes (NFC), except NFPA 5000, published by the National Fire Protection Association (NFPA). Scope of Work Locations: All cable runs connect a video device (patient/veteran waiting areas) to the nearest IT communications closet as follows: Dental Waiting Area -- 2nd Floor, Bldg. 71 -- 170 cable run (not including maintenance loop of 3 meters per switch, if required) Radiology Waiting Area -- 2nd Floor, Bldg. 71N -- 78 cable run (not including maintenance loop of 3 meters per switch, if required) Ambulatory Care Waiting Area -- 1st Floor, Bldg. 71 -- 75 cable run (not including maintenance loop of 3 meters per switch, if required) Pharmacy Waiting Area -- 2nd Floor, Bldg. 71N -- 38 cable run (not including maintenance loop of 3 meters per switch, if required) Laboratory Waiting Area -- 2nd Floor, Bldg. 71N -- 50 cable run (not including maintenance loop of 3 meters per switch, if required) Mental Health Waiting Area -- 1st Floor, Bldg. 8 -- 38 cable run (not including maintenance loop of 3 meters per switch, if required)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/36C25918Q9607/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25918Q9607 36C25918Q9607_3.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4436996&FileName=36C25918Q9607-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4436996&FileName=36C25918Q9607-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA Medical Center;1898 Fort Road;Sheridan WY
Zip Code: 82801
 
Record
SN04970049-W 20180629/180627230700-05ec989dd0dd83e0d5586718396ff944 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.