DOCUMENT
71 -- Patient & Guest Seating - Attachment
- Notice Date
- 6/27/2018
- Notice Type
- Attachment
- NAICS
- 337121
— Upholstered Household Furniture Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 10;3140 Governor ™s Place Blvd. Suite 210;Kettering OH 45409-1337
- ZIP Code
- 45409-1337
- Solicitation Number
- 36C25018Q9364
- Response Due
- 7/2/2018
- Archive Date
- 8/1/2018
- Point of Contact
- Angie Carpenter
- E-Mail Address
-
carpenter@va.gov<br
- Small Business Set-Aside
- N/A
- Description
- DEPARTMNET OF VETERANS AFFAIRS NETWORK CONTRACTING OFFICE 10 (NCO 10) Description: THIS IS A SOURCES SOUGHT NOTICE ONLY. The singular purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The information obtained through this notice will be utilized exclusively as market research for acquisition planning purposes. Background: Louis Stokes Cleveland VA Medical Center is seeking the replacement of (165) patient chairs, (180) guest chairs, and (30) Ottomans (13 height) at the Wade Park Facility, Main Hospital. This requirement is for the procurement, set up and delivery, and installation at LSCVAMC, 10701 East Blvd, Cleveland, OH 44106. NAICS Code: 337121, Upholstered Household Furniture Manufacturing, and Small Business Size Standard is 1,000 Employees. NOTE: Respondents claiming SDVOSB and VOSB status must be registered and CVE certified in VetBiz registry www.vetbiz.gov. Small businesses must meet the Small Business Non-Manufacturer Rule in order for the procurement to be set-aside. REQUIREMENTS: The requested manufacturer is Weiland Sauder. Part Number Description Quantity 6357122 Trace Metal Frame Patient High Back Chair, 22 Wide 165 6351122 Trace Metal Frame Low Back Chair (Guest-Waiting), 22 Wide 180 6350100 Trace Metal Frame 13 Ottoman 30 The below characteristics of the replacement chairs mimic the comfort and support features of wooden frames while reducing maintenance concerns typical of wooden furnishings. Wooden frames are heavy and require special care and special cleaners compared to the metal frame alternative. Technological advances with vinyl textiles allow for preferred cleaning methods and reduce risk of infection compared to products previously provided. In addition, wall-saver designs protect the wall behind the furnishings; ergonomic designs provide increased support and comfort to the patient or guest; and innovative product design which allows quick cleaning of the seats. Therefore, with input from EMS teams, trade publications, and nursing management, these furnishings are considered to be the best design fit for the functions needed on these units Salient characteristics of Patient Seating: Overall dimensions: height 43 inches; width 26 inches; depth 25.5 inches Weight capacity: 500 lbs. Seat Height: 18.5 inches from finished floor Ability to accept vinyl COMS at Fabric Grade G: Headrest Zone-Stinson Nishiki Sumi; Seat and Lower Back-Monmentum Silica Cusp Java Powder-coated 17-gauge steel frame Molded wood under seat and outer back panel is standard Fully upholstered seat and back Urethan arm cap, sable urethan color Wood underseat panel, finish #80 Sepia Wood panel outer back, finish #80 Sepia A clean out is incorporated between seat and back Ottoman nests neatly beneath seat Wide, flat arm caps and healthful geometries all provide a higher level of patient comfort 25-year warranty Salient characteristics of the Guest Seating: Overall dimensions: height 32.75 inches; width 26 inches; depth 24.25 inches Weight capacity: 500 lbs. Seat height 18.5 inches from finished floor Ability to accept vinyl COMs at Fabric Grade G: Monmentum Silica Arc Azure Powder-coated 17-gauge steel frame Molded wood under seat and outer back panel is standard Fully upholstered seat and back Urethane arm cap, sable urethane color Wood underseat panel, finish #80 Sepia Wood panel outer back, finish #80 Sepia A clean out is incorporated between seat and back Wide, flat arm caps and healthful geometrics all provide a higher level of patient comfort 25-year warranty Salient characteristics of 13 Ottoman: Overall dimensions: height 13 inches; width 18.5 inches; depth 17 inches Fully compatible with high back patient seating Fully upholstered foot stool STINSON: NISHIKI SUMI 25-year warranty Products must be new, not refurbished, used, or grey-market type. Capability statement/information sought: Response to this announcement shall include the following information: A tailored capability statement indicating the firm s ability to provide a product and related services to include delivery time period upon receipt of a possible order; Documentation and/or specification sheets for all items; The respondent s DUNS number, organization name, address, point of contact, and size and type of business (e.g., SDVOSB/VOSB, etc) pursuant to the applicable NAICS Code; Letter from OEM that offeror is an authorized distributor/reseller; A statement identifying if items can be procured through FSS/GSA schedules or open market THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary, the government assumes no financial responsibility for any costs incurred. Responses to this notice must be made via email to angie.carpenter@va.gov. Responses may be submitted as attachments and must be clearly marked Sources Sought Patient & Guest Seating in the subject line and document header. The deadline to respond is Monday, 2 July 2018, at 2:00PM EST. As a reminder this is a Sources Sought announcement only, evaluation letters will be not be issued to any respondent, nor will the Government be required to pay for any costs incurred for responses submitted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/36C25018Q9364/listing.html)
- Document(s)
- Attachment
- File Name: 36C25018Q9364 36C25018Q9364.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4433833&FileName=36C25018Q9364-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4433833&FileName=36C25018Q9364-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25018Q9364 36C25018Q9364.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4433833&FileName=36C25018Q9364-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;Louis Stokes Cleveland VA Medical Center;Cleveland OH
- Zip Code: 44106-1702
- Zip Code: 44106-1702
- Record
- SN04970965-W 20180629/180627231029-3bc5e3b450ded1451fbdeeac696e452b (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |