Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 01, 2018 FBO #6064
SOURCES SOUGHT

Y -- Renovation of Building 201 - Sources Sought Bidder Information Form

Notice Date
6/29/2018
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Norfolk, 803 Front Street, Norfolk, Virginia, 23510-1096, United States
 
ZIP Code
23510-1096
 
Solicitation Number
W91236-18-B-0025
 
Archive Date
7/28/2018
 
Point of Contact
Jaime C. Scott Howard, Phone: 7572017158, Joy M. Wright, Phone: 7572017145
 
E-Mail Address
jaime.c.scott@usace.army.mil, joy.m.wright@usace.army.mil
(jaime.c.scott@usace.army.mil, joy.m.wright@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Sources Sought Bidder Information Form This is a Sources Sought notice only; it is not a request for competitive proposals. There is no solicitation, specifications, and/or drawings available at this time. This Sources Sought Notice is for informational purposes only to determine the interest and availability of potential qualified contractors. The Government will not reimburse respondents for any cost incurred in preparation of a response to this notice. The Government intends to use responses to this Sources Sought to make appropriate acquisition decisions for the project. NO AWARD will be made from this Sources Sought notice. ALL INTERESTED FIRMS SHOULD RESPOND TO THIS NOTICE NO MATTER WHAT BUSINESS SIZE UNDER THE NAICS CODE 236220. Project Description: The Norfolk District, Corps of Engineers is conducting Market Research to identify potential Sources for the Renovate Building 20 project at DLA / DSCR, Chesterfield County, Richmond, Virginia. The project will provide renovations to Building 201, which contains the Emergency Services for DLA Richmond, including the Fire and Police Departments. The work includes roof removal and replacement, including damaged roof decking. It also includes replacement of roof insulation and adjustments to the roof gutters and downspouts to solve a standing water issue directly outside the building. The scope includes interior repairs to damaged ceiling tiles, repairs and painting to interior walls, carpet replacement, wall and base cabinet repairs and replacement, repairs and updates to the Fire Protection System to meet Class A system, including mass notification system installation. Other interior changes includes wall removals, wall replacements, kitchen renovations, repairs to shower rooms, provision of new lockers in shower rooms, air conditioning repairs and replacements, and replacement of Direct Digital Controls. The Fire Department area will require the replacement of large overhead fire doors in the area where the fire trucks are housed. Asbestos and lead paint are also present on the interior of the building and must also be abated prior to construction. The area must be made handicapped-accessible in accordance with the current standards of the Architectural Barriers Act (ABA), and must be made compliant with all current ATFP standards, including UFC 4-010-1. The project includes normal sustainability requirements. The anticipated period of performance is 450 calendar days. This Sources Sought anticipates the need for a laydown area for the project, as well as a trailer that can accommodate eleven fire fighters for cooking, eating and sleeping comfortably for at least two months. The project is located on the corner of "G" and "L" road, and the building has some smaller laydown areas behind it that should be available for work during regular working hours (7:00am to 4:30pm). No holiday work is anticipated. The smaller laydown area will be used for the trailer with a large kitchen and dining area and a sleeping area for eleven personnel, as well as several conex-type boxes for storage of items that need to be removed from the building during construction. The Contracting Officer has classified this requirement as Commercial and Institutional Building Construction - North American Industry Classification System (NAICS) code 236220. The small business size standard is $36.5 million. The order of magnitude for this effort is estimated between $1,000,000.00 and $5,000,000.00. Contractors will be required to submit bonding documents prior to award. Bonding documents are not required for this Sources Sought. Only interested, capable, qualified and responsive small business contractors with the minimum capabilities (i.e. Refer to Project Description & Description of Experience) are encouraged to reply to this Sources Sought announcement. Based on definitions above, for each project submitted, include: a.Current percentage of construction complete and the date when it was or will be completed. b.Scope of the project c.Size of the project d.Dollar value of the project e.The portion and percentage of work that was self-performed The Sources Sought response should demonstrate knowledge of, experience in, and ability to successfully execute. It is anticipated that the Government will issue a firm fixed price contract. Interested contractors must furnish the following information: General Information: 1. Bidders must complete the attached Sources Sought Bidder Information Form to detail the following: 2. Company name, address, phone number and point of contact. 3. Indicate business size in relation to the NAICS code 236220. Provide your company's Cage Code and DUNS number to verify your business status as a qualified Small Business (SB), Service Disabled Veteran Owned SB (SDVOSB), Historically Underutilized Business Zones (HUBZones), Qualified Section 8(a), Women-Owned or other small business. Contractors must be registered in the System for Award Management (SAM) at the time of contract award. Please see www.sam.gov for additional registration information. 4. Provide a narrative indicating the primary nature of your business. Narratives shall be no longer than five (5) pages and shall demonstrate experience in a similar type of work as described, at a similar contract value, and in a similar location. 5. The level of performance and payment bonding capacity that the company could attain for the proposed project. 6. Descriptions of Experience - Provide descriptions of your firm's past experience on projects with: a. Demonstrate experience renovating occupied spaces consisting of administrative and offices including bathroom areas b. Demonstrate experience applying for and obtaining environmental permits c. Demonstrate experience in the removal of mold, asbestos and lead-based paint from administrative spaces d. Demonstrate previous work experience on a Department of Defense or Government installation 7. Provide two (2) or three (3) examples of successful projects similar to requirements described in the project description above that have been accomplished within the past five (5) years. Please demonstrate five (5) continuous years of successfully accomplishing this type of work at a similar contract value, in a similar type of location. If a specialty sub-contractor is used, the sub-contractor shall also provide work examples and experience. All submitters shall include point of contact information for work examples provided, and past performance on the projects, so that verification can take place. Submitters with unsatisfactory past performance may not be considered capable of successfully performing this type of work. Since this is a Sources Sought announcement only, no evaluation letters and/or results will be issued to the respondents. No solicitation exists and solicitation requests will not be acknowledged. USACE Norfolk District is not seeking or accepting unsolicited proposals, and will not accept telephone inquiries. All questions and correspondence shall be directed via email at jaime.c.scott@usace.army.mil. No reimbursement will be made to any costs associated with providing information in response to this announcement. All responses to this announcement may be sent electronically to jaime.c.scott@usace.army.mil with copy furnished to joy.m.wright@usace.army.mil no later than 1:00p.m. (EST), 13 July 2018. Limit capability briefing package to 10 pages. Email is the preferred method by USACE to receive responses to this synopsis. This Sources Sought should not be construed in any manner to be an obligation of the U.S. Corps of Engineers, Norfolk District to issue a contract, or result in any claim for reimbursement of costs for any effort you expend responding to this request.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA65/W91236-18-B-0025/listing.html)
 
Place of Performance
Address: Defense Supply Center Richmond (DSCR) - Building 201, Chesterfield, Virginia, United States
 
Record
SN04974765-W 20180701/180629231020-aeb1d37503a43ca23afb03d1e6fd9aab (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.