Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 01, 2018 FBO #6064
MODIFICATION

Y -- Colebrook Dam Electrical Upgrades - Amendment 1

Notice Date
6/29/2018
 
Notice Type
Modification/Amendment
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, New England, 696 Virginia Road, Concord, Massachusetts, 01742-2751, United States
 
ZIP Code
01742-2751
 
Solicitation Number
W912WJ18B0011
 
Archive Date
5/31/2018
 
Point of Contact
Ben Hoell, Phone: 9783188084, Jessica M. Kidd,
 
E-Mail Address
ben.hoell@usace.army.mil, jessica.m.kidd@usace.army.mil
(ben.hoell@usace.army.mil, jessica.m.kidd@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
W912WJ18B0011-0001 Electrical Upgrades at the Colebrook Dam Pre-Solicitation Notice The U.S. Army Corps of Engineers, New England District is issuing a set aside for certified small business contractors for Electrical Upgrades at the Colebrook Dam, located in Riverton, CT. The NAICS code for the work described below is 238210 (Size Standard $15.0 Million). The project is planned to be issued in June 2018, and will be set aside for Small Businesses. The construction will extend over a one-month period occurring in the summer or fall of 2018. The estimated magnitude of this project is between $100,000 and $250,000. Any responsible source meeting this standard may submit a bid to be considered by the New England District. This project consists of the following Scope: • Replace the existing pad-mounted transformer at the entrance to the service bridge with a new pad-mounted transformer in the same location, using the same concrete pad. Transformer is a medium-voltage transformer, and is original to the dam. Transformer shall be treated as if it contains PCBs • Replace the feeder from the above transformer to the dam tower. This will involve pulling wire through the ground for about 20 feet from the transformer to the end of the service bridge where it starts at the dam crest road, and then pulling wire through the suspended metal conduit that is currently emplaced underneath the service bridge. • Replace the electrical breaker panels inside the tower • Install a manual transfer switch (also called a "double throw safety switch") inside the tower • Install a generator start button inside the tower Additionally, the Government anticipates including a Definitive Responsibility Criterion (DRC) for this future solicitation. The DRC requirement means that if the apparent low bidder cannot meet this requirement, then the award would shift to the next lowest bidder who can substantiate this experience. This experience documentation would be not be requested until award is made. The Definitive Responsibility Criterion consist of: "Interested firms should be able to provide a copy of a current E-1 (Unlimited electrical contractor's) license from the State of Connecticut." Firms may use subcontractors to meet this Criterion. Please note this solicitation is set aside for certified small businesses. This is not a request for proposals at this time, the solicitation requirements and contract documents to include instructions for submission and the response date will be available on or about June, 2018. Neither telephonic, mailed nor faxed requests for hard copies of this solicitation will be accepted. The solicitation will only be available online; in order to download the solicitation offerors must access the Federal Business Opportunities website (www.fbo.gov). All responsible sources may submit a bid which shall be considered by the New England District. Additional questions may be emailed to the Contract Specialist at Ben.Hoell@usace.army.mil. Amendment #1 This amendment is issued to provide responses to questions from the Colebrook Dam pre-bid site visit of 27 June 2018, to record the Contractor attendee list from the Colebrook Dam site visit, and to answer Requests for Information (RFI). Except as provided in the attached Amendment, all terms and conditions of W912WJ18B0011 are unchanged.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA33/W912WJ18B0011/listing.html)
 
Place of Performance
Address: Colebrook River Road, Colebrook, Connecticut, 06021, United States
Zip Code: 06021
 
Record
SN04975171-W 20180701/180629231150-9298eff4bcd3e144e443225761f8c9f8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.