Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 27, 2018 FBO #6090
SOURCES SOUGHT

65 -- 553-18-3-063-0102 Beds

Notice Date
7/25/2018
 
Notice Type
Synopsis
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veteran Affairs;Network Contracting Office 10;5500 Armstrong Rd.;Battle Creek MI 49037
 
ZIP Code
49037
 
Solicitation Number
36C25018Q9544
 
Response Due
7/31/2018
 
Archive Date
10/29/2018
 
Point of Contact
brooke.hansen@va.gov
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the following: The interest and capability of small business, especially service disabled veteran owned small business and veteran owned small business; Whether the business source is a manufacturer or authorized distributor, verified by an authorization letter from the original equipment manufacturer; and Size classification relative to the North American Industry Classification System (NAICS) code 334510 for the proposed acquisition. The Department of Veterans Affairs, Network Contracting Office 10 is seeking potential sources for an Hill-Rom, brand name or equal, to be provided for the John Dingell VA Medical Center 46467 John R Rd Detroit, MI 48201. All items shall be new; refurbished/used items are not acceptable. Brand name or equal requirements: Quantity: 8 ICU beds that have the exact features mentioned below: Retractable Foot Control 30 °/45 ° Head-of-Bed Alarm In-Bed Scale 3-Mode Bed Exit Alarm (PPM) Standard Head and Foot Panel Night Light Steering Caster Hands Free Emergency CPR, Trendelenburg Siderails Control Smart Bed Ready Obstacle Detect System at Both Sides of the Bed Drainage Bag Holders Four IV Pole Sockets Safe Working Load: 650 lbs Patient Controls Backlighting Trapeze brackets available Bed Controls Line Managers Caregiver Pendant Foot Controls Module Oxygen Tank Holder Module Accessory Outlet As for technical specifications: Length 88" (223.5 cm) Width 40.5" (103 cm) Percussion and vibration modules Highest Position: Top of Seat Section to Floor 35" (89 cm) Lowest Position: Top of Seat Section to Floor 16.5" (41.9 cm) Standard Caster 6" (15.24 cm) Safe Working Load 650 lbs (295 kgs) Maximum Patient Weight 500 lbs (227 kgs) C-Arm Clearance 7-15" (17.8-38.1 cm) Voltages 100/110/115/120/ 127/220/230/240 Fluid Ingress Protection IPX4 Radiolucent Sleep Deck Stnd 17.7" x 23" (45 cm x 58.5 cm) Place of Manufacture USA Articulation Specifications Head 0 °-67 ° Thigh 0 °-30 ° Foot 0 °-70 ° Trendelenburg 13 ° Tilt Table Function (Reverse Trendelenburg) -18 ° Quantity: 12 ICU beds that have the exact features mentioned below: Weight based pressure redistribution in any bed position 3-layer surface cover with in-built X-ray sleeve siderail controls with Graphical Caregiver Interface feature. Digital Head of bed angle indicator and alarm   3 mode bed exit sensor with alarm silence and alarm suspend modes Chair capability and chair egress with stand assist One-button patient repositioning support electrical bed retraction and extension Hands-free emergency CPR and Trendelenburg History data on patient weight, head of bed elevation and chair position Turn Assist with reminder function Power driven transport Emergency Trendelenburg/Reverse Trendelenburg: 20 °/20 °(Siderail Trendelenburg/reverse Trendelenburg is 15 °) Trapeze brackets available As for technical specifications: The beds must have a weight capacity of at least 500lb Overall length of 81.5 inches when bed is retracted and 93.5 inches when bed is fully extended. The width of the ICU beds must be 36.5 inches when side rails are stowed and 40 inches when side rails are up. All contractors that are interested in meeting this requirement are asked to submit the following information: Company Name Company Address DUNS Number Company POC Name Company POC Phone Company POC Email Business Size/Type under NAICS 334510 GSA Contract Number (if applicable) If proposing equal items, provide detailed documentation showing how the proposed items are equal to the Ultra Clean Systems brand. Additional information: All contractors must be registered with the System for Award Management (SAM) at https://www.sam.gov. Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with the Vendor Information Pages (VIP) at https://www.vip.vetbiz.gov as an SDVOSB or VOSB. Responses due to Brooke Hansen, Contracting Officer, by Tuesday, July 31, 2018 at 4:00PM. Please e-mail all responses to brooke.hansen@va.gov. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (25-JUL-2018); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/BCVAMC515/BCVAMC515/36C25018Q9544/listing.html)
 
Place of Performance
Address: John D Dingell VA Medical Center;4646 John R Street;Detroit, MI
Zip Code: 48201
Country: US
 
Record
SN05006147-F 20180727/180725230807 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.