Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 27, 2018 FBO #6090
SOLICITATION NOTICE

36 -- 2 each Vertical Carousel Office Filing / Storage Unit

Notice Date
7/25/2018
 
Notice Type
Combine Synopsis/Solicitation
 
Contracting Office
Western Region Training Support Center, P.O. Box 339500 MS 16E, WA 98433
 
ZIP Code
22030
 
Solicitation Number
TAL8117
 
Response Due
8/31/2018
 
Archive Date
2/27/2019
 
Point of Contact
Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
 
E-Mail Address
Clientservices@fedbid.com;
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. The solicitation number is TAL8117 and is issued as an invitation for bids (IFB), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-99. The associated North American Industrial Classification System (NAICS) code for this procurement is 423420 with a small business size standard of 100.00 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2018-08-31 16:30:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be JOINT BASE LEWIS-MCCHORD, WA 98433 The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: Vertical Carousel must be of Ergonomic Design All Vertical Carousels must be Clip System panel concept for fast assemble/disassemble and for maintenance purposes allowing for high operator security in the event that stored goods fall inside the unit. 2-year warranty, including transportation, parts and labor. Vertical Carousels shall come equipped with an Emergency Power Crank for access to parts in case of power failure Vertical Carousels shall come equipped with a multifunctional profile allowing flexible fitment and positioning of operator panel, lighting and accessories above access opening. Vertical Carousels shall come equipped with a stainless-steel table surface at a standing position. Vertical Carousel shall have an imbalance indicator located on the operator station display that will alert the operator to any imbalance load. Vertical Carousels shall come equipped with a lockable lightweight one piece sliding door. Self-counterbalanced sliding door can be opened and closed with minimal effort. Two-piece sliding doors without counterbalance are not acceptable. Vertical Carousels must have 100% Reliable Safety Security System Vertical Carousels shall come equipped with finger protection safety buffer at rear of posting board. Vertical Carousels must come with transport rollers for fast and easy repositioning in the case of internal moves, providing maximum flexibility for unit positioning with minimum downtime and reinstallation costs. Vertical Carousels must have standard manual override systems allowing for the unit to be used until service technician s repair. Vertical Carousels must have a standard manual override that can be operated with the door open, so parts can be located using drive and view , without having to know what carrier the part is stored on. The contactor must ensure the equipment complies with DIN EN 15095 Power-operated mobile racking and shelving, carousels and storage lifts and has been tested and certified by TÜV (Technical Observation & Control), a USA NRTL and a Canadian CB. 5. OVERALL EQUIPMENT SPECIFICATION: Vertical Carousel Shop Area (1 each): Overall Unit Height: 234.70 Minimum Room Height for Installation: 236.70 Overall Unit Width: 121.1 Overall Unit Depth: 78.40 Includes 12.6 - Work Counter Cubic Storage per Unit: 486.1 ft Storage Area per Unit: 364.2 ft Power Supply: 3/PE 230V (50/60 Hz) Rated Operating Current: 12 A Motor Power: 3 HP ; 2.2 KW Fuse Protection: 2 A t Control Generation C3000 Power Consumption: 4. kVA Controller Location: End Frame, Right Side E Stop Location: (1) per Side Panel (2 Total) Controller: OPLogicontrol Table Height 39.37 in, Stainless Steel / Fixed Work Counter Access Opening Light Door Type: Automatic w/Electronic Lock Carriers per Unit: (22) Multipurpose Carriers Spacing (Pitch): 18 Carrier Clear Height: 16.02 / Includes: 0.31 in. front lip Carrier Clear Width: 96.5 Carrier Clear Depth: 24.7 in. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (25-JUL-2018); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/notices/9cf1e628f9249bdd6b590225781473b9)
 
Place of Performance
Address: JOINT BASE LEWIS-MCCHORD, WA 98433
Zip Code: 98433-9500
Country: US
 
Record
SN05006636-F 20180727/180725230830 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.