Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 08, 2018 FBO #6102
SOLICITATION NOTICE

J -- St Stephen's Fire Protection - Package #1

Notice Date
8/6/2018
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333999 — All Other Miscellaneous General Purpose Machinery Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Mobile, P. O. Box 2288, 109 Saint Joseph Street (zip 36602), Mobile, Alabama, 36628-0001, United States
 
ZIP Code
36628-0001
 
Solicitation Number
W9127818R0084
 
Point of Contact
Jason B. Meyers, Phone: 2516944108, Joan Rensink, Phone: 2514416172
 
E-Mail Address
jason.b.meyers@usace.army.mil, joan.a.rensink@usace.army.mil
(jason.b.meyers@usace.army.mil, joan.a.rensink@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Pictures from a Trip Report Drawing Color Drawing C Drawing B Drawing A Solicitation 8-6 Contract to remove, dispose of existing fire protection (CO2) and provide and install a more modernized fire protection system. This project will result in the elimination of CO2 from the powerhouse interior providing a safer work space for all plant personnel and visitors. All new and modified systems will be Underwriters Laboratories (UL) or Factory Mutual (FM) listed and designed to applicable National Fire Protection Association (NFPA). This section is a general summary of the work and is not all-inclusive. The work described within these specifications shall include, but not necessarily be limited to the following: (a) Removal of three existing high pressure CO2 fire protection systems, first, one serving the oil purification and oil storage rooms, second, one serving the flammable storage room, and thirdly, one serving three hydroelectric generators, (b) Provision of temporary suitable manual fire protection until the new fire protection systems are operable and accepted, (c) Detailed design, provision, and installation of water mist fire protection systems for the oil purification room, oil storage room, and flammable storage room, (d) Detailed design, provision, and installation of clean agent fire protection systems for three hydroelectric generators, (e) Testing, demonstration, and training for fine water mist fire protection system and clean agent system, as well as cleanup of any water or oily water in the powerhouse resulting from testing, demonstrations, or training, (f) Detailed design, provision, and installation of complete electrical power system, controls, and all detection and annunciation devices for each new fire protection system, and (g) Appurtenant concrete work, seismic restraint, and fire-stopping. Work will be performed at the St. Stephen Powerhouse Dam, St. Stephen, SC.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA01/W9127818R0084/listing.html)
 
Place of Performance
Address: St Stephen Hydro Power Plant, 1275 Rediversion Road, St Stephen, South Carolina, 29479, United States
Zip Code: 29479
 
Record
SN05021770-W 20180808/180806230901-fab703512d46565079386611de59c2ed (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.