70 -- ThePANalytical Empyrean X-Ray Diffraction System or Equal - RFQ

Notice Date
8/29/2018
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Army, Army Contracting Command, ACC - RSA (W9124P) - SPS, 5300 Martin Rd, Redstone Arsenal, Alabama, 35898-0001, United States
 
ZIP Code
35898-0001
 
Solicitation Number
W9124P-18-R-5126
 
Archive Date
9/20/2018
 
Point of Contact
Gosia M. Thompson, Phone: 2568422784
 
E-Mail Address
gosia.m.thompson.civ@mail.mil
(gosia.m.thompson.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
System Description RFQ letter Purchase Description Purchase of a PANalytical Empyrean X-Ray Diffraction System or Equal Background: An X-ray powder diffractometer is needed by the Materials Science & Engineering Division to support the AMCOM Corrosion Program Office with phase identification of corrosion products. Performance Requirements: The Diffractometer system shall be in an enclosure that prevents operator exposure from either direct or scattered x-ray beam. The enclosure shall meet all local, State, and Federal X-Ray radiation safety requirements for all possible anode types to include Copper, Cobalt, Chromium, Molybdenum, Manganese, and Silver. The doors shall be leaded and slide open for easy access to the goniometer optics and sample stages and be clear for viewing. The cabinet/enclosure shall have safety interlocks with electromagnetic shutter mechanism. The radiation cabinet shall have integrated lead sliding panels with direct beam stop. The cabinet interior shall be lighted. The diffraction system shall have a key lock to prevent unauthorized use of the system. Power settings for the diffractometer system shall be readily displayed on the front of the physical instrument. The radiation enclosure cabinet shall also contain an electronics rack and system controller. The X-ray Unit shall have two independent safety features that monitor when the shutter can open. If the doors to the cabinet are open, the shutter shall not open. System shall include data acquisition software that contains the following functionality: data acquisition based on the XRDML data platform, measurement strategy determination tools, configuration and measurement strategy determination tools, configuration and measurement management, automatic processing, data conversion and viewing functionality for X-ray diffraction systems. The analysis software shall be licensed for installation on up to three computers and not have to use license keys or dongles via hardware or network connectivity. Operation and execution of the software shall be fully multi-tasking with in the Windows 10 environment. The X-ray Tube Design shall allow the physical rotation of the X-ray Tube Body that results in the anode surface being rotated from line projection to point projection as required for utilization of maximum X-ray Tube flux in either line or point modes. Tube replacement and exchange should be possible by trained end user. The diffraction system shall have independent operation of each theta (omega) axis. The angular range of the goniometer shall be 360 degrees in omega without the use of accessories and -111 to 168 degrees for two-theta. Minimum step size shall be 0.0001 degrees in both omega and two-theta. Slew speed shall be at least 15 degrees per second. System shall include a pixilated solid state detector with a maximum pixel dimension of 55 micron. Detector to be maintenance free and not use detector gases. Additionally, the protective window of the detector shall not be made of toxic materials such as beryllium. X-ray Unit shall operate on Single Phase 180 - 253 V, 47 - 63 Hz System shall have an X-ray generator of 4kW (max 60kV, 100mA max), Tube voltage, 15 - 60 kV, Tube Current 5 - 60 mA. In addition to the above, the Diffraction system shall have the following: System shall have a 240mm minimum radius theta-theta goniometer and source module for the X-ray tube, Quantity 1. Sealed Tube, X-ray generator that is fully integrated within the automated diffraction system and is compatible with the goniometer, Quantity 1. X-ray Tube, Cobalt anode, Long Fine Focal spot to accommodate line and point focus. Max Power 1.8 kW, quantity 1 Square Sample Holders, Set of 25 square aluminum sample holders with a 15mm X 20mm area for powder specimens, used with a clip stage, quantity 1. Set of two (2) silicon single crystal substrates, 32 mm in diameter and 2mm thick, for measuring small amounts of sample material requiring low background intensity. One side of the substrate is flat, the other side recessed 15mm dia and 0.2mm deep, quantity 1. Multi-Purpose Sample Stage with manual phi and z axes to enable manual tilting over 6 degrees when doing phase analysis, omega-stress, reflectometry and thin film applications, quantity 1. Dial gauge for sample height adjustments and alignment to be used with proper positioning on the stage, quantity 1. Sample stage for sample spinning circular sample holders, with programmable phi-axis positioning or scanning. This stage shall be able to be used in both reflection and transmission mode. Also included is the sample spinner changer interface. Quantity 1. Set of Bottom sample plates (3 pieces) for sample holder rings, set of 3. Quantity 2. Sample Holder top, 16mm internal diameter, 2.4mm thickness, set of 3. Used for back-loading or front loading of powder specimens, either manually or semi-automatically, quantity 1. Sample Holder Top, 27mm internal diameter, 2.4mm thickness, set of 3. Used for back loading or front loading of powder specimens, either manually or semi-automatically, quantity 1. Powder Sample Preparation Kit for Round Powder Holders. Kit shall be comprised of a sample preparation table, a powder press block or piston, a dusting brush, and a Stanley Knife blade. Quantity 1. Sample Holder, 46mm internal diameter, 6.5mm max thickness, set of 3. For front loading of solid samples. Supports scans starting at 0 degrees 2theta. Quantity 1. Silicon Substrate, Zero Background insert, 32mm diameter, 2mm thickness, set of 2 silicon single crystal substrates. Used for measurements of small amounts of sample that requires low background intensity. Quantity 1. Transmission Holder, Set of 3. Accepts inserts of 6mm thick and 40 mm diameter. For analysis in the transmission geometry. Used for clamping thin foils or fibers. The inner diameter ring is 25mm, the maximum 2Theta angle is transmission geometry is 120 degrees. Quantity 1. Insert Transmission, Set of 3, Inserts for analyzing samples in transmission geometry. Inner diameter of the ring is 25mm, the maximum 2Theta angle in transmission geometry is 120 degrees. Box of 500 X-ray transparent foils, for use with insert for air sensitive sample holders, insert for transmission sample holders or disposable inserts for transmission sample holders, The foils have a diameter of 63.5mm and are cut in a circular shape. The material of the foils to be polyimide, with thickness of 7.5 micrometer. Quantity 1. Prefix, Parallel Plate Collimator to limit the angular divergence of a diffracted x-ray beam to 0.18 degrees, to include 0.1 mm slit for reflectivity measurements. Quantity 1. Large Beta-Filter Fe (for Cobalt Radiation), reducing Co K-Beta line to less than 1% of the Co K-Alpha intensity. Quantity 1. Soller Slit, Large 0.04 Radian, large aperture for diffracted beam anti-scatter device. Quantity 1. Interface for mounting a PIXcel detector on the flat graphite monochromator for Cobalt Radiation, Quantity 1. PIXcel PET detector and PreFIX interface for line and point detector applications. Features 99% count rate linearity to 98,000 cps per pixel, static 2theta range of 3.3 degrees at standard 240 mm radius and 6 degrees or 14.4 degrees static 2 theta range with optional radius reduction interfaces. Quantity 1. Electronics board for up to 2 linear detectors, Quantity 1. Fixed Antiscatter slit assembly for the PIXcel detector, Includes 13.4, 11.2, 7.5 and 6mm and one alignment slit of 0.2mm. Quantity 1. Chromium Reflectivity Reference Sample. Sample is comprised of a thin chromium film on glass that is used to check the alignment of the parallel plate collimators. Quantity 1. Cobalt BBHD Optic, Quantity 1. Dual Network Card to be used with alignment camera, Quantity 1. HIGHSCORE LTU 1-3 Software to perform data treatments and XRD phase identification. Shall include search match algorithm using peak and profile data, auto-residue scoring, advanced reporting functions, graphics for examining, displaying and editing diffractograms. Supports user defined data bases, includes batch feature for auto function sequence, automation ready, similar analysis of scans, reference intensity ratio for estimation of quantities of all identified phases, percent crystallinity, fast profile fitting, line profile analysis, PLS partial least squares to determine/quantify one property directly from the raw data. Windows 10 complaint. Quantity 1. Plus Option Highscore Software to integrate functionality with crystallography, structures fit, and microstructure analysis on data from various systems. Shall be able to perform similarity analysis of scans, unit cell indexing, unit cell refinement, space group testing and unit cell transformation, structure reviewing (distances and angles calculations), structure solution by charge flipping, line profile analysis, microstructure analysis by profile and structures fit, mixed fits from structure. Shall be Windows 10 compliant. Quantity 1. PDF-4 Plus License, Database for phase identification (search match) and for structure fits. Shall be windows 10 compliant. Quantity 1. X'Pert Stress software License for measurement of residual stress. Shall be Windows 10 Compliant. Quantity 1. High End computer, Monitor and printer. Computer operating system must be Windows 10, designed to run diffraction software and Search Databases and interface with X-ray Diffractometer, Quantity 1. XRD On Site Expertise Training, 2 days. This training shall be separate from any operations training by the service/installation engineer at the time of installation. Quantity 1. Water Cooled Water Chiller LX2-W2, with Accessory Kit, Quantity 1. Installation of Floor Standing Systems. Installation shall be performed by factory trained customer support engineer. A pre-installation manual has to be provided to assist purchaser in the planning of the installation. Quantity 1. One Year Warranty for XRD System, Quantity 1. X-ray Tube shall have a two year (non pro-rated) failure warranty. Shipping of XRD Systems and Accessories, Quantity 1. Travel: Travel is will be part of this purchase, to install system and two day training. Deliverables: The contractor shall provide deliverables to the following: US Army RDECOM RDMR-WDP-MA (Sherry Watson) Building 7631, Bat Road Redstone Arsenal, AL 35898-5260
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/f6d0201254f68b9c16a4ec8eccb85940)
 
Place of Performance
Address: US Army RDECOM, RDMR-WDP-MA (Sherry Watson), Building 7631, Bat Road, Redstone Arsenal, Alabama, 35898, United States
Zip Code: 35898
 
Record
SN05062229-W 20180831/180829231453-f6d0201254f68b9c16a4ec8eccb85940 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.