Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 18, 2019 FBO #6265
SOLICITATION NOTICE

65 -- Iridex IQ 532 laser system and IQ 577 laser system (Notice of intent to perform oral solicitation)

Notice Date
1/16/2019
 
Notice Type
Synopsis
 
NAICS
339115 — Ophthalmic Goods Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
 
ZIP Code
98662
 
Solicitation Number
36C26019Q0188
 
Response Due
1/21/2019
 
Archive Date
1/31/2019
 
Point of Contact
gregory.watson2@va.gov
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
In accordance with FAR 13.106-1 (c )(1), the Department of Veterans Affairs intends to perform oral solicitations for 1 EA Iridex IQ 577 laser system and 1 EA Iridex IQ 532 laser system. This will be set-aside for SDVOSB s. To be considered eligible for award all SDVOSB s must be registered/verified through Vetbiz.gov. If you wish to be included in this solicitation, please respond electronically to gregory.watson2@va.gov by 5 PM PST Monday January 21st 2019. This solicitation will be performed on Tuesday January 22nd. This will be a brand name or equal to solicitation to the following Items Manufactured by Iridex: Item Part Number Description Qty 9770600 Site~Rite 8r Ultrasound System Console (9770600), System includes: Console only (no probe), one year warranty, console, power supply, line cord, and electronic IFU. 4 9770131 Sherlock 3CGT Tip Confirmation System (9770131)This part number includes the sensor ONLY 4 9770116 Medical Equipment Roll Stand (MER) (9770116) Order 9770109 for laptop style ultrasound systems 4 9770508 SHERLOCK 3CGT Diamond TCS Activation Key for the Site~Riter 8 Ultrasound System (9770508) Software Key 4 9770509 DICOM / Connectivity Software for the Site~Riter 8 Ultrasound System - Activation Key (9770509) Connectivity (DICOM Send/ Store) 4 MW260MFIC129 BrotherT MW-260 Printer (MW260MFIC129) Requires 9770108 for use with MER Roll Stand. Mounting hardware not included. 4 9770517 Site~Riter Keyboard (9770517) Keyboard 4 9770602 Site~Rite 8r 20mm Pinpoint GT Probe (9770602) 20mm Pinpoint GT Probe for the Site~Rite 8r Ultrasound System 4 Shipping Address: Seattle VA Medical Center 1660 SOUTH COLUMBIAN WAY Seattle, WA 98108 To be considered technically acceptable, the products must meet the following minimum salient characteristics: Must meet minimum salient characteristics to be technically acceptable: The Iridex IQ 532 laser system is a green laser with micropulse technology that is used for retinal and glaucoma laserprocedures. Salient Characteristics 532 nm wavelength Can deliver up to 2500 mW of laser power High speed with pulse durations from 10 to 3000 ms Dual port for simultaneous connectivity of laser delivery devices Must have Wireless Footswitch Must have micropulse technology which breaks up the continuous wave beam into short pulses; adjustable duty cycles from 0.4% to 50% and preset selections of 5%, 10%, 15% duty cycles. Must have Laser indirect ophthalmoscopy option Must have wheelchair table Must have slit lamp that can mount to TxCell laser Must have beamsplitter and co-observer tube Must have safety glasses Must have multi-spot pattern scanning for pan retinal photocoagulation such as 2x2; 7 x 7 grid, circle and triple arc. Must have target grid Must have single spot mode and multisport patter mode Must have standard photocoagulation settings, fovea-friendly micropulse laser therapy for retinal diseases and micropulse laser trabeculoplasty for repeatable glaucoma TxCell must be in Haag-Streit Style configuration for slit lamp Must have voice confirmation of power settings The Iridex IQ 577 laser system is a yellow laser with micropulse technology that is used for retinal and glaucoma laser procedures. The 577nm allows for peak absorption in oxygenated hemoglobin. Salient Characteristics 577nm wavelength allows for peak absorption in oxygenated hemoglobin and dense ocular media and lower transmission to deeper tissues. High speed with pulse durations from 10 to 3000 ms Dual port for simultaneous connectivity of laser delivery devices Must have Wireless Footswitch Must have micropulse technology which breaks up the continuous wave beam into short pulses; adjustable duty cycles from 0.4% to 50% and preset selections of 5%, 10%, 15% duty cycles. Must have Laser indirect ophthalmoscopy option Must have wheelchair table Must have slit lamp that can mount to TxCell laser Must have beamsplitter and co-observer tube Must have safety glasses Must have multi-spot pattern scanning for pan retinal photocoagulation such as 2x2; 7 x 7 grid, circle and triple arc. Must have target grid Must have single spot mode and multisport patter mode Must have standard photocoagulation settings, fovea-friendly micropulse laser therapy for retinal diseases and micropulse laser trabeculoplasty for repeatable glaucoma TxCell must be in Haag-Streit Style configuration for slit lamp Must have voice confirmation of power settings 339115 Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system such that OEM warranty and service are provided and maintained by the OEM. All software licensing, warranty, and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. This procurement is for new Equipment ONLY; no remanufactured or "gray market" items. All Equipment must be covered by the manufacturer's warranty. (a) Gray market items are Original Equipment Manufacturer s (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the medical supplies, medical equipment and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. (c) The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract. Accordingly, the VA reserves the right enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA s election, allowing the Vendor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA medical facility upon discovery of such items. *This notice satisfies the requirement at FAR 5.201 to synopsize proposed contract actions.* NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (16-JAN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/PoVAMC/VAMCCO80220/36C26019Q0188/listing.html)
 
Place of Performance
Address: Seattle VA Medical Center;1660 SOUTH COLUMBIAN WAY;Seattle, WA
Zip Code: 98108
Country: USA
 
Record
SN05195940-F 20190118/190116230010 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.