Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 27, 2019 FBO #6274
SOLICITATION NOTICE

J -- Tri-Annual Electrical Distribution Testing / Inspection | ref: 538-19-1-6068-0004

Notice Date
1/25/2019
 
Notice Type
Synopsis
 
NAICS
561210 — Facilities Support Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 10;260 E. University Avenue;Cincinnati OH 45219
 
ZIP Code
45219
 
Solicitation Number
36C25019Q0304
 
Response Due
1/31/2019
 
Archive Date
5/10/2019
 
Point of Contact
megan.wallace@va.gov
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
STATEMENT OF WORK (SOW) Contract Title: Tri-Annual Electrical Distribution Testing / Inspection Place of Performance: Chillicothe VA Medical Center 17273 State Route 104 Chillicothe, OH 45601 Period of Performance: July through October 2019 Background: Requirement set by VA Directive 1028 Scope: The proposed three-year electrical distribution check will include the cleaning, inspecting, lubricating and testing of the Chillicothe, Ohio Veteran s Administration Medical Center (VAMC) electrical power distribution system. Testing will be performed by NETA certified technicians whose certification included OSHA safety training and arc-flash training. The effort will be accomplished over a split three-month period. Once the contract has been awarded, the exact project dates will be negotiated including any power outages necessary to accomplish the required testing. Specific Tasks: MAIN SUBSTATION ITEM #1. ONE (1) GENERAL ELECTRIC 15KV 1200A THREE PHASE DRAW-OUT VACUUM CIRCUIT BREAKER. Clean, inspect, lubricate, and test as per appendix #1 ITEM #2. THREE (3) BASLER ELECTRIC TYPE BE1-50/51 SINGLE PHASE TIME OVER CURRENT RELAYS. Clean, inspect, lubricate, and test as per appendix #2 ITEM #3. TWO (2) PACIFIC CREST ELECTRIC 7500KVA 12470V-4160/2400V THREE PHASE OIL FILLED POWER TRANSFORMERS. Clean, inspect, and test as per appendix #3 BACK-UP GENERATOR (OUTDOOR) ITEM #4. TWO (2) SQUARE D ELECTRIC 5KV 1200A TYPE VR THREE PHASE DRAW-OUT VACUUM CIRCUIT BREAKERS. Clean, inspect, lubricate, and test as per appendix #1 ITEM #5. ONE (1) GENERAL ELECTRIC TYPE MULTILIN SR-750 THREE PHASE TIME OVER CURRENT SYSTEM PROTECTION RELAY. Clean, inspect, lubricate, and test as per appendix #2 ITEM #6. ONE (1) GENERAL ELECTRIC TYPE 489 THREE PHASE MULTI-FUNCTION GENERATOR PROTECTION RELAY. Clean, inspect, lubricate, and test as per appendix #2 5KV CIRCUIT BREAKERS ITEM #7. EIGHT (8) WESTINGHOUSE ELECTRIC 5KV 1200A TYPE 50-DHP-250 THREE PHASE DRAW-OUT AIR MAGNETIC CIRCUIT BREAKERS. Clean, inspect, lubricate and test as per appendix #4 ITEM #8. THIRTY-TWO (32) WESTINGHOUSE ELECTRIC TYPE CO-8 50/51 SINGLE PHASE TIME OVERCURRENT RELAYS. Clean, inspect, and test as per appendix #2 PARALLELING SWITCHGEAR (INDOOR) ITEM #9. FIVE (5) SQUARE D ELECTRIC 5KV 1200A TYPE VR THREE PHASE DRAW-OUT VACUUM CIRCUIT BREAKERS. Clean, inspect, lubricate, and test as per appendix #1 ITEM #10. TWO (2) BASLER ELECTRIC TYPE BE1-851 THREE PHASE TIME OVER CURRENT SYSTEM PROTECTION RELAYS. Clean, inspect, lubricate, and test as per appendix #2 BUILDING #LC-7 ITEM #11. ONE (1) COOPER ELECTRIC 750KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #12. ONE (1) WESTINGHOUSE ELECTRIC 480V 1600A TYPE DS-416 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #5 ITEM #13. EIGHT (8) WESTINGHOUSE ELECTRIC 480V 800A TYPE DS-206 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKERS. Clean, inspect, lubricate and test as per appendix #5 ITEM #14. ONE (1) WESTINGHOUSE ELECTRIC 480V 1600A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 CHAPEL BUILDING #252 ITEM #15. ONE (1) COOPER ELECTRIC 150KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 BUILDING #24 ITEM #16. ONE (1) PAUWELS ELECTRIC 750KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #17. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A TYPE DS-416 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #5 ITEM #18. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #24 (CHILLER) ITEM #19. ONE (1) T&R ELECTRIC 300KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 BUILDING #26 ITEM #20. ONE (1) COOPER ELECTRIC 500KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #21. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A TYPE DS-416 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #5 ITEM #22. ELEVEN (11) WESTINGHOUSE ELECTRIC 208V 800A TYPE DS-206 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKERS. Clean, inspect, lubricate and test as per appendix #5 ITEM #23. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #27 ITEM #24. ONE (1) COOPER ELECTRIC 500KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #25. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A TYPE DS-416 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #5 ITEM #26. ELEVEN (11) WESTINGHOUSE ELECTRIC 208V 800A TYPE DS-206 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKERS. Clean, inspect, lubricate and test as per appendix #5 ITEM #27. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #30 ITEM #28. ONE (1) WESTINGHOUSE ELECTRIC 300KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #29. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A TYPE DS-416 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #5 ITEM #30. TWELVE (12) WESTINGHOUSE ELECTRIC 208V 800A TYPE DS-206 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKERS. Clean, inspect, lubricate and test as per appendix #5 ITEM #31. ONE (1) WESTINGHOUSE ELECTRIC 208V 1600A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #30 (CHILLER) ITEM #32. ONE (1) SQUARE D ELECTRIC 300KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 BUILDING #35 ITEM #33. ONE (1) COOPER ELECTRIC 500KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #34. ONE (1) WESTINGHOUSE ELECTRIC 208V 2000A TYPE DS-420 THREE PHASE DRAW-OUT AIR FRAME CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #5 ITEM #35. ONE (1) WESTINGHOUSE ELECTRIC 208V 2000A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #210 ITEM #36. ONE (1) GE PROLEC 750KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #37. ONE (1) CUTLER HAMMER ELECTRIC 208V 2000A TYPE 310 + TRIP UNIT THREE PHASE STATIONARY MOUNTED CIRCUIT BREAKER. Clean, inspect, lubricate and megger, and contact resistance test. ITEM #38. ONE (1) GENERAL ELECTRIC 208V 2000A TYPE HPC THREE PHASE FUSED BOLTED PRESSURE SWITCH. Clean, inspect, lubricate and test as per appendix #7 ITEM #39. ONE (1) GENERAL ELECTRIC 208V 2000A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #210 (CHILLER) ITEM #40. ONE (1) GE PROLEC 500KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 BUILDING #211 ITEM #41. ONE (1) SQUARE D ELECTRIC 1000KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #42. ONE (1) SQUARE D ELECTRIC 208V 3000A TYPE BP THREE PHASE FUSED BOLTED PRESSURE SWITCH. Clean, inspect, lubricate and test as per appendix #7 ITEM #43. ONE (1) SQUARE D ELECTRIC 208V 3000A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 BUILDING #211 (CHILLER) ITEM #44. ONE (1) CG POWER 750KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 BOILER PLANT #261 ITEM #45. ONE (1) COOPER ELECTRIC 750KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #46. ONE (1) CUTLER HAMMER ELECTRIC 480V 2000A TYPE MAGNUM DS THREE PHASE STATIONARY MOUNTED INSULATED CASE CIRCUIT BREAKER. Clean, inspect, lubricate and test as per appendix #8 ITEM #47. ONE (1) CUTLER HAMMER ELECTRIC 480V 2000A TYPE MAGNUM DS THREE PHASE STATIONARY MOUNTED INSULATED CASE CIRCUIT BREAKER. Clean, inspect, lubricate, and contact resistance test BUILDING #1 ITEM #48. ONE (1) COOPER ELECTRIC 300KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #3 ITEM #49. ONE (1) COOPER ELECTRIC 150KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #8 ITEM #50. ONE (1) COOPER ELECTRIC 75KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #9 ITEM #51. ONE (1) COOPER ELECTRIC 150KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #25 ITEM #52. ONE (1) COOPER ELECTRIC 500KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #28 ITEM #53. ONE (1) COOPER ELECTRIC 300KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #36 ITEM #54. ONE (1) COOPER ELECTRIC 225KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #53 ITEM #55. ONE (1) COOPER ELECTRIC 75KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #212 ITEM #56. ONE (1) COOPER ELECTRIC 300KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #247 ITEM #57. ONE (1) COOPER ELECTRIC 300KVA 4160V-208/120V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #256 ITEM #58. ONE (1) COOPER ELECTRIC 112.5KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #8 BUILDING #31 ITEM #59. ONE (1) SQUARE D 2000KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #60. ONE (1) SQUARE D 1500KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #61. ONE (1) SQUARE D 750KVA 4160V-480/277V THREE PHASE OIL FILLED POWER TRANSFORMER. Clean, inspect, and test as per appendix #3 ITEM #62. TWO (2) SQUARE D ELECTRIC (INDOOR) 480V 3000A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 ITEM #63. ONE (1) SQUARE D ELECTRIC (OUTDOOR) 480V 3000A THREE PHASE METAL ENCLOSED SWITCHGEAR STRUCTURE. Clean, inspect, and test as per appendix #6 ITEM #64. TWO (2) SQUARE D ELECTRIC 480V 3000A, NW 30 H CIRCUIT BREAKER, NEMA AB1/NMX-J-266-ANCE Clean, inspect, lubricate and test as per appendix #5 ITEM #65. ELEVEN (11) SQUARE D ELECTRIC 480V 400A, LG400 CIRCUIT BREAKER Clean, inspect, lubricate and test as per appendix #5 ITEM #66. FIVE (5) SQUARE D ELECTRIC 480V 600A, LG600 CIRCUIT BREAKER,   Clean, inspect, lubricate and test as per appendix #5 ITEM #67. FIVE (5) SQUARE D ELECTRIC 480V 800A, PG800 CIRCUIT BREAKER,   Clean, inspect, lubricate and test as per appendix #5 ITEM #68. THREE (3) SQUARE D ELECTRIC 480V 150A, HG600 CIRCUIT BREAKER,   Clean, inspect, lubricate and test as per appendix #5 ITEM #69. ONE (1) SQUARE D ELECTRIC 480V 1600A, RG1600 CIRCUIT BREAKER,   Clean, inspect, lubricate and test as per appendix #5 ITEM #70. ONE (1) SQUARE D ELECTRIC 480V 250A, JG250 CIRCUIT BREAKER,   Clean, inspect, lubricate and test as per appendix #5 APPENDIX #1 CIRCUIT BREAKER - MEDIUM VOLTAGE - VACUUM A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical damage. q Compare equipment nameplate data with drawings and specifications. q Inspect anchorage, alignment, and grounding. q Perform all mechanical operational tests on both the circuit breaker and it's operating mechanism. q Operate the breaker to confirm manual charge, trip & close functions. B) ELECTRICAL TESTS q Perform a contact resistance test on each phase of breaker, and the same test, line bus to load bus, with breaker in the cubicle. q Perform insulation resistance tests, pole-to-pole, pole-to-ground, and across open poles at 2500V minimum. q Perform vacuum bottle integrity test (overpotential) across each vacuum bottle with the breaker in the open position in strict accordance with man APPENDIX #2 PROTECTIVE RELAYS SOLID STATE A) VISUAL AND MECHANICAL INSPECTION q Relays shall be inspected for physical damage. q Compare equipment nameplate data with drawing and specifications. q Tighten case connections. Inspect shorting hardware, connection paddles, and/or knife switches. Remove any foreign material from the case. Verify target reset. q Set relays in accordance with coordination data to be supplied by the Engineer. B) ELECTRICAL TESTS q Perform the following tests on the nominal settings specified by owner/user's electrical engineer: a) Pickup parameters on each operating element. b) Timing test shall be performed. c) Pickup targets and seal in units. d) Special tests as required to check operation of restraint, direction, and other elements per manufacturer's instructions. APPENDIX #3 TRANSFORMERS - LIQUID FILLED A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical damage. Make a close examination for all damage that may have occurred as the result of environment, or other problems, which could interfere with normal operation. q Compare equipment nameplate information with latest single-line diagram and report discrepancies. q Verify proper manual operation such as fans, pumps, indicators, tap changer, and gas pressurization system. q Check all liquid in tanks and bushings for proper level and inspect for oil leaks. B) ELECTRICAL TESTS q Insulation resistance tests shall be performed winding-to-winding and winding-to-ground. Appropriate guard shall be utilized over all bushings. q Insulation power factor tests shall be made on all high and low voltage winding and bushings. Overall dielectric loss and power factor (CH, CL, CHL) shall be determined. Ungrounded specimen tests (UST) shall be made on any bushing equipped with power factor or capacitance taps. q A turn s ratio test shall be performed between windings for all tap positions. The final tap setting is to be determined by the equipment owner and set by the testing laboratory. q Perform winding resistance test on each winding in final tap position. q Perform current-excitation test on each winding. q Insulating oil shall be sampled in accordance with ASTM D-923. Sample shall be laboratory tested for: a) Dielectric breakdown voltage b) Acid neutralization number c) Specific gravity d) Interfacial tension e) Color, Visual condition f) Perform dissolved gas a APPENDIX #4 CIRCUIT BREAKERS - MEDIUM VOLTAGE - AIR A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical damage, cleanliness, and adequate lubrication. q Inspect anchorage, alignment, and grounding. q Perform all mechanical operator and contact alignment tests on both the breaker and it's operating mechanism. q Check tightness of bolted. q Check cell fit and element alignment. q Check racking mechanism. q Lubricate all moving current carrying parts. q Check for proper operation of the cubicle shutter. B) ELECTRICAL TESTS q Measure contact resistance. q Measure insulation resistance pole-to-pole, pole-to-ground, and across open poles. Use a minimum test voltage of 2500 volts. q Perform power factor test with breaker in both the open and closed position. APPENDIX #5 CIRCUIT BREAKERS - LOW VOLTAGE - POWER A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical damage. q Perform mechanical operational test. q Check cell fit and element alignment. q Check arc chutes for damage. q Clean entire circuit breaker using approved methods and materials. q Lubricate as required. B) ELECTRICAL TESTS q Perform a contact resistance test. q Perform an insulation resistance test at 1000 volts DC from pole-to-pole and from each pole-to-ground with breaker closed and across open contacts of each phase. q Determine minimum pickup current by secondary current injection. q Determine long time delay by secondary injection. q Determine short time pickup and delay by secondary current injection. q Determine ground fault pickup and delay by secondary current injection. q Determine instantaneous pickup value by secondary current injection. q Check charging mechanism. APPENDIX #6 480V SWITCHGEAR ASSEMBLIES A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical, electrical, and mechanical condition. q Compare equipment nameplate information with latest single line diagram and report discrepancies. q Check for proper anchorage, required area clearances, physical damage, and proper alignment. q All doors, panels, and sections shall be inspected for paint, dents, scratches and fit. q Verify that fuse and/or circuit breaker sizes and types correspond to drawings and coordination study as well as to the circuit breaker s address for microprocessor-communication package. q Verify correct barrier and shutter installation and operation. q Exercise active components. B) ELECTRICAL TESTS q Perform insulation-resistance tests on each bus section, phase to phase and phase to ground. APPENDIX# 7 BOLTED PRESSURE SWITCH A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical damage. q Perform mechanical operator tests in accordance with manufacturer's instructions. q Check blade alignment and arc interrupter operation. q Check fuse linkage and element for proper holder and current rating. q Check key interlocks for safe operation and proper key distribution. B) ELECTRICAL TESTS q Perform insulation resistance tests on each phase (open pole only). q Perform contact resistance test across each switch blade and fuse holder. q Perform ground fault pickup and proper operation, if applicable. APPENDIX #8 TRANSFORMERS - LIQUID FILLED A) VISUAL AND MECHANICAL INSPECTION q Inspect for physical damage. Make a close examination for all damage that may have occurred as the result of environment, or other problems, which could interfere with normal operation. q Compare equipment nameplate information with latest single-line diagram and report discrepancies. q Check all liquid in tanks and bushings for proper level and inspect for oil leaks. B) ELECTRICAL TESTS q Insulating oil shall be sampled in accordance with ASTM D-923. Sample shall be laboratory tested for: a) Dielectric breakdown voltage b) Acid neutralization number c) Specific gravity d) Interfacial tension e) Color, Visual condition f) Perform dissolved gas analysis (DGA) g) PPM water Deliverables: Report of all inspections, testing, and findings Performance Monitoring: Monitoring will be conducted by the VA electrical supervisor Security Requirements: None Government Furnished Equipment (GFE)/Government-Furnished Information (GFI): None NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (25-JAN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/CiVAMC/VAMCCO80220/36C25019Q0304/listing.html)
 
Record
SN05202986-F 20190127/190125230009 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.