SOURCES SOUGHT
65 -- Eyecubed ABD
- Notice Date
- 3/8/2019
- Notice Type
- Synopsis
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 4
- ZIP Code
- 19104
- Solicitation Number
- 36C24419Q0420
- Response Due
- 3/15/2019
- Archive Date
- 3/30/2019
- Point of Contact
- Louellen Butler
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- THIS SPECIAL NOTICE IS NOT A REQUEST FOR QUOTES. This notice is for informational purposes only. This is a Sources Sought Notice 36C24419Q0420; is neither a solicitation nor a promise of future work. Wilkes-Barre VAMC, 111 East End Blvd, Wilkes-Barre, PA 18711-0030 (693) is seeking SDVOSB/VOSB and any SBS regardless of Socio-economic category that can provide an EYECUBED ABD in accordance with the listed Salient Characteristics. This is brand name or equal, brand name is EYECUBED-ABD, MANUFACTURER ELLEX, INC. B-Scan Modes; Four sets of electronic distance measurement calipers with variable velocity; 2 sets of electronic angle measurement calipers (variable velocity); Movie sequence real-time viewing and editing capability EYECUBED ABD 10 MHz Posterior Segment; 25 frames-per-second image acquisition rate; 10-second movie loop capability; sealed probe; adjustable transmit gain (minimum to 0dB); adjustable receive gain (27-90 dB); Adjustable dynamic range (Log, S1, S2, S3); axial resolution: 50 microns; lateral resolution: 100 microns; scanning angle: 52 degrees; Image depth (displayed image): 48 mm; focal depth: 25mm; image width at focal zone: 19-36 mm; focal range: 15-35 mm EYECUBED Ultrasound SI Cart DISCOM Digital Imaging and Communication 40 MHz UBM Wide-Field Anterior Segment; 13 frames-per-second image acquisition rate; 20-second movie loop capability; adjustable transmit gain (minimum to 0dB)adjustable receive gain (27-90 dB); adjustable dynamic range (Log, S1, S2, S3); axial resolution: 23 microns; lateral resolution: 33 microns; image depth (displayed image): 11.9 mm; image width at focal zone: 15-18 mm; focal range: 10.5 14.5 mm; focal depth: 12.5 mm. A-Scan Modes; IOL power calculations and analysis: Holladay-I; SRK-T; Haigis (optional); Hoffer-Q; 50 frames-per-second image acquisition rate; Movie sequence adjustable up to 5 seconds Axial Length Biometry A-Scan; Immersion or contact method; solid focused probe with internal fixation light; probe frequency 10MHz; image depth: 40mm; points on x-axis: 2048; 8 bit resolution; measurement accuracy: 50 microns inherent, 100 microns clinical; automatic or manual scan acquisition; built-in patter recognition with automatic scleral echo detection; statistics: average and standard deviation. Standardized Diagnostic A-Scan; two caliper measurements displayed in mm with variable velocities; tissue sensitivity value stored in memory with reset function; probe frequency: 8 MHz parallel beam; measurement accuracy: 50 microns inherent, 100 microns clinical. Network connectivity: six USB 2.0 ports for memory sticks and peripherals; fully network and printer-ready (gigabit Ethernet); Purpose-built Windows embedded operating system; multilingual user interface Data Management: data archiving and image export capability; customized report capability; DICOM connectivity; verification of multiple concurrent DICOM connections to other Application Entities (AEs); Query/retrieval of modality work list (patient data from Electronic Medical Records EMR); Storage of DICOM objects to EMR/Picture Archiving and Communication Systems (PACS) Hardware Features: footswotch control (scan start, scan stop, scan save, etc.); removable one-terabyte hard drive; wide screen, 1920 x 1200 high-resolution monitor Electrical Requirements: power supply 100-240 VAC auto-ranging; frequency 50/60 Hz; input power 220VA; system size: 15.5 x 17 x 6.5 inches (39 x 43 x 16.5 cm); weight: 26 lbs Eyecubed Ultrasound SI Cart Must be compatible with Eyecubed ABD 40MHz UMB Probe already on-site in AOPC. Must be approved by VHA OI&T and compatible to work with Veterans Information Systems and Technology Architecture (VistA) The items should be delivered to the Wilkes-Barre VAMC, 1111 East End Blvd, Wilkes Barre, PA 18711; Weekdays 8:00am 4:00pm, excluding any government holidays. The veteran business must be registered in SAM and certified in VETBIZ (VIP). The small businesses must be registered in SAM. All vendors interested in, and with the capability and capacity to fulfill this requirement, are required to furnish the following minimum information in reply to this Sources Sought: Company Name, address, Government Business Point of Contact, telephone number and email address. Company DUNs number, CAGE Code, and Tax ID number. Identify any current Federal Supply Schedule, GSA Contracts held, if none then state that no FSS/GSA schedules are held. Responses shall be submitted electronically, via email to Louellen Butler at Louellen.butler@va.gove due no later than Friday 03-15-2019 at 1:00 pm. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (08-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24419Q0420/listing.html)
- Place of Performance
- Address: Wilkes-Barre Va Medical Center;1111 East End Blvd;Wilkes-Barre, PA
- Zip Code: 18711-0030
- Country: USA
- Zip Code: 18711-0030
- Record
- SN05244618-F 20190310/190308230022 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |