Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 15, 2019 FBO #6321
SOURCES SOUGHT

Z -- VIEQUES NATIONAL WILDLIFE REFUGE PV SYSTEM REPAIR

Notice Date
3/13/2019
 
Notice Type
Synopsis
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
FWS, DIVISION OF CONTRACTING AND GR<br />1875 CENTURY BOULEVARD<br />SUITE 310<br />ATLANTA<br />GA<br />30345-3310<br />US<br />
 
ZIP Code
30345
 
Solicitation Number
140F0419R0014
 
Point of Contact
Moody, Khanhthong
 
Small Business Set-Aside
N/A
 
Description
The US Fish & Wildlife Service has a requirement for the following project. If you are interested, please submit your detailed capabilities in WRITING to demonstrate same or similar experience. This is not a request for proposal or invitation to bid. No proposal package, solicitation, specification or drawings are available with this announcement. Response to this announcement is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this sources sought announcement or any follow-up information requests. If you choose to submit a package, clearly identify the project on your package and reference 140F0419R0014. Your email capability information MUST be 10 pages or less; and be SPECIFIC to the scope provided. You must also provide a letter from a federally approved bonding company verifying your bonding levels. Your response is due no later than 3:00 pm Eastern Standard Time on March 22, 2019. The Government anticipates conducting a competitive acquisition for this requirement. The amount of interest or lack thereof will determine the possibility of a competitive set-aside or full and open competition (the size of a small business firm includes all parents, subsidiaries, affiliates, etc.-see 13 CFR 121.108.) Misrepresentation of size status can result in penalties. All firms should be registered and certified in www.SAM.gov and www.ipp.gov. Send your email responses to Khanhthong_Moody@fws.gov. Analysis of the quality of responses to this sources sought announcement will be considered in the market research being conducted; and in the making of any small business set-aside determination for this requirement. NAICS Code: 236220 (Repair or Alternation of Government- Own Building) PSC Code: Z2HB (Commercial and Institutional Building Construction) Estimated Cost Range: $800,000 - $1,000,000 Estimated Period of Performance: 180 Days after Notice to Proceed (TBD) Project Description: See Attached Statement of Work & PV Assessment Project Location: Camp Garcia/Maintenance Compound Vieques National Wildlife Refuge, Road 997 KM 3.2, Vieques, PR 00775 The intent of this project consists of the following: 1. Repair or replace the racking system. New support structure need to comply with ASCE7-2016 code and be able to withstand winds speeds up to 175MPH. 2. Pour concrete slab bellow the PV module. 2" reinforce concrete. 3,000PSI 3. Replace 259, 290 watt PV panels. Utilize new designed support hardware for PV panels for high wind environment. 4. Replace damaged 80 KW generator with similar 80 KW generator to include an aluminum enclosure with 415 gallon diesel tank. 5. Replace damaged batteries with Tesvolt Li-Ion 480MWh battery system compatible for CMA System installed. 6. Label and tag all electrical components, conduits and wiring as per NEC requirements for PV system 7. Contractor shall repair or install new grounding system as needed. 8. Replace the roof and walls of the electrical room. The damaged metal wall will be replaced with concrete block. Entire building will be painted. Coordinate color with refuge manager. 9. Replace all five (5) doors of the electrical room. 10. Install two exhaust fans. 11. Install four wall louvers. 12. Replace 300' of chain link fence. 13. Contractor shall provide three copies of as-built drawings post construction. Firms interested in the project should possess the following specialized skills and experience, in their responses to this Notice. Criterion A - Describe your experience with photovoltaic Distribution System Repairs. Provide sample projects with a contract value of more than $500,000 that demonstrate completing the project on time and on budget, taking into account problems encountered on the identified contracts and the offeror's corrective actions. Criterion B - Describe your experience as it relates to repair and/or constructions from previous projects located in Puerto Rico. Criterion C Estimate the cost of construction for the project. Bonding Capability - Interested firms MUST provide an official letter from their bonding company to confirm their bonding capacity. Contracting Office Address: 1875 Century Blvd., Atlanta, GA 30345 Place of Performance: Camp Garcia/Maintenance Compound Vieques National Wildlife Refuge, Road 997 KM 3.2, Vieques, PR 00775 Questions or clarifications concerning any ambiguities in the sources sought shall be immediately addressed in e-mail to Khanhthong Moody, Contract Specialist Email: Khanhthong_Moody@fws.gov Phone: 404-679-4022 NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (13-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/DOI/FWS/CGSWO/140F0419R0014/listing.html)
 
Record
SN05248361-F 20190315/190313230044 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.