SOURCES SOUGHT
J -- Service to provide inspections, preventive maintenance, and certifications of Chemical Fume Hoods, Class II Biological Safety Cabinets, Laminar Flow Units, Clean Rooms, & Barrier Isolators at the COLUMBIA MO VAMC.
- Notice Date
- 3/15/2019
- Notice Type
- Synopsis
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street Trafficway;Leavenworth KS 66048
- ZIP Code
- 66048
- Solicitation Number
- 36C25519Q0293
- Response Due
- 3/22/2019
- Archive Date
- 5/21/2019
- Point of Contact
- CARA.WOODRING@VA.GOV
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. Work to be performed: Provide inspections, perform preventive maintenance (including cleaning) and certifications of Chemical Fume Hoods, Class II Biological Safety Cabinets (Type A and Type B), Laminar Flow Units, Clean Rooms, and Barrier Isolators at the Harry S. Truman Memorial Veterans Hospital in Columbia MO. This work shall be accomplished on a semi-annual basis. Contractor shall ensure that equipment serviced by this contract functions in compliance with the most up to date published edition of the applicable standards including the NSF, NIH, EPA, JCAHO, UL, OSHA, ASHRAE, CDRH, and VA standards. The Contractor will be responsible to ensure that Contractor Employees providing work on this contract are fully trained, NSF accredited, and completely competent to perform the required work. Equipment used in performance of the contract by Contractor Employees will function in conformance with the latest published edition of the applicable standards including the NSF, NIH, EPA, JCAHO, UL, OSHA, CDRH, and VA standards. All equipment tested shall be properly labeled/tagged after certification completion and prior to leaving site. Semi-annual on-site certifications for Biological Safety Cabinets (BSCs) must be accomplished in accordance with the most current National Sanitation Foundation/American National Standards Institute (NSF/ANSI) Standard 49 Class II (laminar flow) Biosafety Cabinetry. The list of tests includes, but is not limited to: HEPA filter leak test Cabinet leak test Inflow velocity test to include exhaust airflow volume rate Airflow Smoke pattern test Electrical leakage and ground circuit resistance and polarity tests Lighting intensity test Vibration test Noise level test Ultraviolet (UV) lamp test The North American Industry Classification System Code (NAICS Code) is 811219 (Other Electronic and precision Equipment Repair and Maintenance), size standard $20.5 Million Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a small business, VOSB or SDVOSB. Important information: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open. Any response to this source selection from Interested parties must be received NLT 03/22/2019. Attention: Cara J. Woodring, Contracting Specialist. Email: cara.woodring@va.gov Phone: 913-946-1988 Fax: 913-946-1996 NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (15-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/36C25519Q0293/listing.html)
- Place of Performance
- Zip Code: 65201
- Record
- SN05251177-F 20190317/190315230024 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |