F -- Industrial Hygiene Assessment Boiler Plant

Notice Date
3/26/2019
 
Notice Type
Synopsis
 
NAICS
541620 — Environmental Consulting Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19;1011 Honor Heights Drive;Greenwood Village CO 80111
 
ZIP Code
74401
 
Solicitation Number
36C25919Q0187
 
Response Due
4/1/2019
 
Archive Date
5/1/2019
 
Point of Contact
mitchael.purdom@va.gov
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
2 Performance Work Statement (PWS) Industrial Hygiene Assessment Boiler Plant Sheridan VA Medical Center 1898 Fort Road Sheridan, WY 82801-8322 Purpose: Veteran Affairs requires a qualified contractor to conduct air quality monitoring at the heating plant and its boiler room at the VAMC in Sheridan, WY. Services must be accomplished in a cost effective, safe, efficient and secure manner for the VA and in support of the VA Mission. Title of Project: Industrial Hygiene Assessment at Boiler Plant Background: There are 8-10 employees of the VAMC in Sheridan, WY that work at the heating plant and its boiler room. During the day shift, two employees work in the heating plant for the 8-hour day shift. Only one employee works a second (evening) shift and one employee works a third (graveyard) shift. After a retrofit of the boilers, fine fly ash is now periodically released from equipment leaks into the boiler room, and this dust is now present on surface throughout. The dust contains both crystalline silica (quartz) and other metals that are all regulated by the US Occupational Safety and Health Administration (OSHA). These metals include, at least beryllium, chromium, lead, manganese, selenium, titanium, and strontium. There is no measurable mercury. Employees use personal respirators, at their discretion, for protection from the dust at this time, when they periodically carry out dusty tasks. Scope of Work: All employee exposure monitoring (air sampling) work must be conducted by a certified industrial hygienist (CIH: www.abih.org). All air and dust samples must be analyzed by a laboratory accredited by the AIHA (www.aiha.org). Any direct reading aerosol monitor must be calibrated per the recommendations of the manufacturer. Conduct both personal breathing zone (PBZ), and area air monitoring for both respirable, crystalline silica dust, and also total dust with metals in the heating plant boiler room air at the VAMC, Sheridan, WY. Conduct PBZ air sampling (exposure monitoring) for employees over the majority of their 8-hour work shift. Conduct the exposure monitoring for both the day, evening, and graveyard work shifts. The dusty operations include the following: When the boiler faults and goes down When the air injection blows off the internal tubes (every 240 min) When the RAL system goes down General cleanup of the area (sweeping, hose down, etc) Other activities such as performing baghouse filter tasks Conduct short term sampling for both respirable dust, and respirable crystalline silica (one sample), and also total dust and metals (another sample). These additional dusty job air samples will be conducted while the employees are still wearing the full work shift exposure monitors. The short-term monitoring could be as short as 15 minutes, or as long as one hour during these dusty jobs. These additional samples can be collected with a second person working alongside the operator, or as simulated breathing zone samples (perhaps by the CIH). Personal breathing zone air exposure monitoring for employees: Air monitoring must be conducted in accordance with the OSHA respirable crystalline silica standard (one lapel of the employee). Air monitoring for total dust and metals (other lapel of the same employee) must be conducted in accordance with NIOSH 0500 and 0600 (total weight), and NIOSH 7303 (metals). The laboratory must report results for respirable dust (mg/m3), and respirable crystalline silica in one report (mg/m3). The second laboratory report must report results for total weight (mg/m3), and also results for concentrations of eight metals in air (mg/m3), including; beryllium, chromium (hexavalent), lead, manganese, selenium, titanium, and strontium, etc. 16 PBZ air samples must be collected spanning the three work shifts for respirable crystalline silica (4-full work shift, 12-short term dusty job exposures). A media blank must also be added to this total. 16 PBZ air samples must be collected spanning the two work shifts for total dust and metals (4-full work shift, 12-short term dusty job exposures). A media blank must also be added to this total. Throughout this exposure monitoring, when appropriate, document concentrations of total dust in air with a hand-held direct-reading, aerosol monitoring, e.g., TSI AM510. Area air monitoring: Area air monitoring must also be conducted in six key locations in the boiler room throughout the same time as the personal air monitoring (6 samples for each work shift) as determined by the CIH. The area sampling locations must be chosen to confirm the path and migration of silica and metal-bearing dust throughout the heating plant, including the break and locker room. Bulk and wipe sampling: The CIH, at their discretion, may perform several wipe and bulk samples to provide additional support of air monitoring strategy and associated results. Reporting: The report must include an introduction, background, methods, results and discussion, and conclusions and recommendations. The report must include a figure depicting the sampling locations, a photo log, laboratory reports, and certificates of calibration of any field instruments. After review of the draft report, a conference call may be necessary to discuss the findings, and a final version of the document must be issued within one week after the time of response of the government. It is possible that the contractor may be asked to return to the site to present the findings of the report to VAMC staff, including the heating plant operator, the industrial hygienist, and administration. 4. Performance Period: A draft report of services must be issued within three weeks from the time of completion of the field work. 5. Contractor Registration: The contractor must have current registration through the System for Award Management Assistance (SAM), https://www.uscontractorregistration.com/. 6. Point of Contact: VA point of contact will be Steve Szmyd, (307) 675-3446. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (26-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/36C25919Q0187/listing.html)
 
Place of Performance
Address: Sheridan VA Medical Center;1898 Fort Road;Sheridan, WY 82801-8322
Zip Code: 82801-8322
Country: USA
 
Record
SN05260603-F 20190328/190326230021 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.