Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 28, 2019 FBO #6334
SOURCES SOUGHT

Y -- KNMD189008 F-22 COMPOSITE REPAIR FACILITY JOINT BASE PEARL HARBOR HICKAM (JBPHH) HI SOURCES SOUGHT

Notice Date
3/26/2019
 
Notice Type
Synopsis
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
91-1179 Enterprise Ave Bldg 117 Kapolei HI 96707
 
ZIP Code
96707
 
Solicitation Number
W912J6-19-R-5000
 
Response Due
4/9/2019
 
Point of Contact
Manuel LLanes, Contracting Specialist, Phone 808-844-6335, Fax 808-844-6340, - Cezar de Veas, Contract Specialist, Phone 808-844-6422
 
E-Mail Address
manuel.llanes.mil@mail.mil, cezar.y.deveas.mil@mail.mil
 
Small Business Set-Aside
Total Small Business
 
Description
PROJECT KNMD189008 F-22 Composite Repair Facility, Joint Base Pearl Harbor Hickam (JBPHH), HI Category: Y- Construction of Structures and Facilities- Potential Sources Sought SYNOPSIS: F-22 COMPOSITE REPAIR FACILITY JOINT BASE PEARL HARBOR HICKAM (JBPHH) HI SOURCES SOUGHT. The purpose of this synopsis is to gain knowledge of potential sources for this project including interested Small Business sources. This notice is for planning purposes only. All interested parties should respond. USPFO for Hawaii may issue a solicitation and award of a contract to "F-22 Composite Repair Facility" located on the Hawaii Air National Guard Campus at Joint Base Pearl Harbor Hickam (JBPHH), Hawaii. The magnitude of this project is between $10,000,000.00 and $25,000,000.00. Project square footage is estimated at 61,800 SF. Project scope includes but is not limited to: construct a third bay addition to the current F-22 Low Observable/Composite Repair Facility (LO/CRF), special corrosion controlled environment for the LO bay, security measures, and specialty climate control systems to regulate temperature, humidity, airflow and fall protection. The project scope also requires tie in to the existing two bay LO facility while maintaining aircraft maintenance operations. Interested offerors are notified and cautioned that contractors may need to demonstrate technical capability with construction on an island environment or other remote geographic location with logistic concerns and tying into an existing facility without interruption to operations. Additionally, contractors may need to demonstrate technical capability with specialized HVAC and fire suppression systems. All interested concerns will provide this office, in writing, a notice stating their positive intention to submit a proposal as a prime contractor no later than 09 Apr 2019. NAICS Code 236220 applies to this project. Your attention is directed to FAR Clause 52.219-14(c)(3) LIMITATIONS ON SUBCONTRACTING which states, "By submission of an offer and execution of a contract, the Offeror/Contractor agrees that in performance of the contract in the case of a contract for General construction, the concern will perform at least 15 percent of the cost of the contract, not including the cost of materials, with its own employees" applies to this project if set aside for small business. This notification, which shall not exceed five (5) single sided typewritten pages, must include 1) a positive statement of intent to bid as a prime contractor and 2) a completed and signed Sources Sought Information Request Form and 3) a listing of project completed within the last three (3) years completed for both Federal, State, Local and private commercial industry clients and 4) a brief outline of resources, subcontractors, and key personnel that would be used to accomplish the project. Include the following information for each project listed: the type of project, the total dollar value, the contract number, the location of performance, and the point of contact for owner/client, and if the construction on an island environment or similar location with remote logistic concerns and if the construction required tying into an existing facility without interruption to operations. Indicate if your firm was a prime or subcontractor during performance of the listed project, and if your firm was a subcontractor provide the name and point of contact information for the prime contract holder. In the event that adequate and qualified small business contractors are not available for adequate competition of this project, it may be advertised and unrestricted. Completed information shall be sent electronically to Manuel Llanes manuel.llanes.mil@mail.mil. Email subject line shall be titled- SOURCES SOUGHT KNMD189008 LOCRF 3rd Bay JBPHH HI-[INSERT YOUR FIRMS NAME]. No hand delivered or facsimile responses will be accepted. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (26-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/USA/NGB/DAHA50/W912J6-19-R-5000/listing.html)
 
Place of Performance
Address: Joint Base Pearl Harbor Hickam Joint Base Pearl Harbor Hickam, HI
Country: US
 
Record
SN05260681-F 20190328/190326230024 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.