Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 31, 2019 FBO #6337
SOURCES SOUGHT

65 -- Electro Stimulator Bioness L300 Go Closes 04/05/2019 Noon EST

Notice Date
3/29/2019
 
Notice Type
Synopsis
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 4;1010 Delafield Road;Pittsburgh, PA 15215
 
ZIP Code
15215
 
Solicitation Number
36C24419Q0486
 
Response Due
4/5/2019
 
Archive Date
5/5/2019
 
Point of Contact
amanda.williams4@va.gov
 
Small Business Set-Aside
N/A
 
Description
Purpose and Objectives: The intent of this Sources Sought Notice is to identify potential businesses especially any Small Businesses and SDVOSB offerors capable of providing the items listed below: These are for the Wilmington VA Medical Center in Wilmington, DE19805. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the below Statement of Need. Responses should include the following information: Business name, address, Business point of Contact. All information is to be submitted via e-mail at Amanda.Williams4@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 12:00 Noon (EST) on Friday, April 05, 2019. No submissions will be accepted after this date and time. Questions can be submitted electronically to Amanda.Williams4@va.gov NLT Thursday, 04-04-19, 3:00 PM EST. This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey. The Wilmington VA Medical Center has a need to purchase an electro-stimulator for the rehab services. The following salient characteristics must be met: A functional electrical stimulation system that produces measurable mobility improvement for patients with foot drop and / or knee instability caused by an upper motor neuron disease or injury. Must include the following features: 3D motion detection for Embedded sensor technology monitors patient movement in all three kinematic planes and triggers stimulation precisely when needed. Multi-channel stimulation with Independent adjustment of medial/lateral stimulation enables precise control of foot inversion/eversion. Fast, intuitive set-up with Fewer components to manage, a Quick Start Fitting Mode and Bluetooth ® programming Outcome measures with standardized assessments to make it easy to objectively track and document patient progress. A home user App so that patient can continue to track and monitor activity and progress at home Indicator lights (status and stimulation lights); stimulation light indicates stimulation on, off, or paused. Audio alerts that alert when: charger is connected; Electrode contact is faulty; charging error has occurred; battery charge level is low; stimulation is turned on/off or paused; system is turned on/off; stimulation unit malfunctions. A rechargeable battery and charging port. Control Unit communicates wirelessly with the Orthosis to turn on/off and pause stimulation, adjust stimulation intensity, and monitor system status. Control Unit features must include: Operating buttons to: turn on/off the wireless system; test stimulation; select/change a user program; enter clinical mode to select a clinical program; turn on/off and pause stimulation; adjust the stimulation intensity level; mute system audio alerts; enter deep sleep mode. On/off lights. Operating modes: three operating modes: gait, training, and clinician Indicators and a digital display: stimulation intensity level; clinical program selected; electronic registration status; control unit battery charging status. Audio alerts when: a button was pressed; RF communication failed; charging error occurred; audio alerts were muted/un-muted; connected or disconnected; system was turned on/off; battery charge level is low; hardware/software error occurred; electronic registration process was initiated, successful, or unsuccessful. Rechargeable battery and charging port. Clinical programs must include: Functional Training Programs Neuroprosthesis Programs Motor Neuromodulation Program Personal Preset Programs Custom Personal Programming Come with separate cuffs for the Lower leg and the Thigh both with Electronic Pulse Generator, a control unit and a foot sensor. Programming that allows System to communicate wirelessly to deliver electrical pulses over the common peroneal nerve and to the motor point of the tibialis anterior muscle, causing ankle dorsiflexion in the swing phase of gait to prevent foot drop. The System can also deliver stimulation to the quadriceps or hamstrings, to provide knee flexion or extension during gait. The System also can deliver stimulation to either or both the muscles in the upper and lower leg Delivery need to be made to Wilmington VA in Wilmington, DE Include a standard warranty. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (29-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24419Q0486/listing.html)
 
Place of Performance
Address: Wilmington VA Medical Center;1601 Kirkwood Highway;Wilmington, DE
Zip Code: 19805
Country: USA
 
Record
SN05264957-F 20190331/190329230019 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.