SOLICITATION NOTICE
65 -- VAAAHS Sensitive RME Sterilizer
- Notice Date
- 4/3/2019
- Notice Type
- Synopsis
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;Ann Arbor Healthcare System;Network Contracting Office 10;2215 Fuller Road;Ann Arbor MI 48105
- ZIP Code
- 48105
- Solicitation Number
- 36C25019Q0514
- Response Due
- 4/12/2019
- Archive Date
- 5/12/2019
- Point of Contact
- charles.lakin2@va.gov
- Small Business Set-Aside
- N/A
- Description
- Page 4 of 4 The Department of Veterans Affairs, Network Contracting Office 10, 24 Frank Lloyd Wright Drive, Lobby M, Suite 2200, Ann Arbor, MI 48105, intends to solicit offers for one (1) Sterrad 100 NX System with AllClear Technology MPN: 10104007or an Equal product. The sterilizer will be delivered FOB Destination to the VAAAHS at 2215 Fuller Road, Ann Arbor, MI 48105 and installed on site by 30 days ARO, according to the terms and conditions stated in this solicitation. This is a 100% SDVOSB set aside procurement that will be conducted using FAR part 13.5 procedures. NAICS code: 339113, small business size standard is 750 employees. The basis of award will be LPTA. The solicitation will be made available on or about 4/4/2019. The contract requirements are anticipated to be: Scope. The contractor shall deliver the Brand Name make and model or an equal sterilizer to the VA Ann Arbor Healthcare System (VAAAHS), 2215 Fuller Road, Ann Arbor, MI 48105. After Delivery and prior to 30 days ARO the contractor shall: Conduct unboxing and installation at the VAAAHS Sterile Processing Service (SPS). Run a test validation kit. Verify to the SPS staff that the unit is functioning properly. Brand Name Item: Sterrad 100 NX System with AllClear Technology MPN: 10104007 Or Equal Salient Characteristics: IAW FAR 11.104(b) an equal product shall meet all of the following physical, functional and/or performance characteristics to be considered acceptable for award: Capability to safely sterilize sensitive RME. Cycle Temperature range below 57 degrees Centigrade. Minimum chamber size of: 405mm high x 505mm wide x 730mm deep. Sterilization cycle of no longer than 60 minutes for any setting. Shall be compatible with a Sterrad Velocity incubator. Equipment provided shall be new manufacture. Refurbished or used equipment will NOT be acceptable. The contractor shall install the equipment on site within 30 days ARO. No solicitation is available at this time. ***No response to this special notice is necessary*** For information about this solicitation, e-mail Chuck Lakin, Contracting Officer, at Charles.Lakin2@va.gov. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (03-APR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/VAAAHCS506/VAAAHCS506/36C25019Q0514/listing.html)
- Place of Performance
- Address: VA Ann Arbor Healthcare System;2215 Fuller Road;Ann Arbor, MI 48105
- Zip Code: 48105
- Country: USA
- Zip Code: 48105
- Record
- SN05269351-F 20190405/190403230021 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |