Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 19, 2019 FBO #6356
SOURCES SOUGHT

66 -- Osmometers

Notice Date
4/17/2019
 
Notice Type
Synopsis
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 10;3140 Governor’s Place Blvd. Suite 210;Kettering OH 45409-1337
 
ZIP Code
45409-1337
 
Solicitation Number
36C25019Q0641
 
Response Due
4/26/2019
 
Archive Date
5/26/2019
 
Point of Contact
angie.carpenter@va.gov
 
Small Business Set-Aside
N/A
 
Description
DEPARTMENT OF VETERANS AFFAIRS NETWORK CONTRACTING OFFICE 10 Description: THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for quotations or quote abstracts. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. Background: The Dayton VA Medical Center, P&LMS, is pursuing the acquisition of one (1) brand new Osmometer analyzer for patient testing. The current primary Advanced Instruments Osmometer 3320 is outdated and irreparable, and no longer serviceable. Purpose and Objectives: Your responses to the information requested will assist the Government in determining the appropriate acquisition method. NAICS Code: 339112 and business size standard is 1,000 employees. NOTE: Respondent claiming SDVOSB and VOSB status must be registered and CVE verified in Vetbiz Registry at https://www.vip.vetbiz.va.gov/. Requirements: The single sample osmometer shall meet the following technical characteristics: Test shall be FDA approved for clinical use. Methodology: Freezing Point Depression Appropriate (minimum of 2 levels) serum and urine controls shall be available 2 Levels of Standards (Low and High) shall be available 1 Reference Solution shall be available Test analysis time of 1 minute or less per sample Linearity: +/- 1% Standard Deviation: 0.5% when result is 400-2000 mOsm/kg H2O Reportable Range: 0-2000 mOsm/kg H2O Sample Volume: 50 microliters or less. Units of Measurement: mOsm/kg H2O Resolution: 1 mOsm/kg H2O Shall be able to print results and use a scanner to scan barcode label Electrical voltage 100-240 VAC Power: 60W Dimensions: Benchtop analyzer shall sit on counter measuring 30 deep or less. Weight of instrument shall be <30 lbs. Instrument shall be able to connect to LIS system. Products shall be new, not refurbished, used, or gray-market type. If vendor has another device meeting similar specs and features to the already given brands/models, please submit appropriate documentation for review. The information identified above is intended to be descriptive, not restrictive, and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (7) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (8) Please submit your capabilities in regard to the technical characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? (9) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (10) Please provide your DUNS number. *** Submissions addressing Section (8) should show clear, compelling and convincing*** evidence that all equal to items" meet all the salient characteristics. Responses to this notice should be emailed to Angie Carpenter at angie.carpenter@va.gov. Telephone responses will not be accepted. Responses shall be received no later than Friday, 26 April 2019, by 4:00PM EST. This notice is to assist the VA in determining sources only. THE VA IS NOT SEEKING PRICING OR OFFERS OF ANY KIND. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside or sole source award, or any other guarantee of award strategy. All information is to be provided on a voluntary basis at no charge to the Government. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (17-APR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/36C25019Q0641/listing.html)
 
Place of Performance
Address: Dayton VA Medical Center;4100 West Third Street;Dayton OH
Zip Code: 45428
Country: USA
 
Record
SN05284421-F 20190419/190417230022 (fbodaily.com)
 
Source