SOURCES SOUGHT
70 -- Sources Sought - VISN Centralized Multi-Modality Radiation Informatics Software License
- Notice Date
- 4/24/2019
- Notice Type
- Synopsis
- NAICS
- 511210
— Software Publishers
- Contracting Office
- Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101;Milwaukee WI 53214-1476
- ZIP Code
- 53214-1476
- Solicitation Number
- 36C25219Q0535
- Response Due
- 4/30/2019
- Archive Date
- 5/30/2019
- Point of Contact
- james.hedman2@va.gov
- Small Business Set-Aside
- N/A
- Description
- This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and Small Businesses, including VIP-Verified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective contractors relative to the North American Industry Classification System (NAICS) Code 511210 (Software Publishers) and the small business size standard is $38.5M. Veterans Integrated Service Network (VISN) 12 is seeking to procure a contract for a Centralized Multi-Modality Radiation Informatics Software License/System. This is contemplated to be a BPA-/IDIQ-type contract. The Government is requesting that Other Than Small Businesses and Small Businesses, including VIP-Verified VOSB or SDVOSB sources respond if it can provide the products and services according to the statement of work (see the Products and Services and Statement of Work sections below) on a Brand Name or Equal basis (Bracco Diagnostics, Inc.). Interested Other Than Small Businesses and Small Businesses including VIP-Verified VOSBs and SDVOSBs are required to submit an e-mail delineating: Qualifications, capabilities, and experience for providing this product; Business size/Socioeconomic status; If the product is on the Federal Supply Schedule or the Open Market; and Memo or correspondence which authorizes distributor to distribute the manufacturer s products (if applicable). This is not a Request for Proposal or an announcement of a solicitation and no solicitation currently exists. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration. Responses due are to be submitted by e-mail to Jim Hedman at james.hedman2@va.gov. The information requested must be received no later than 09:00 a.m. CDT on 4/30/2019. Products and Services (Bracco Diagnostics, Inc. Brand Name or Equal): Line Item Item Number Description Qty Unit 0001 660007 NexoDose Software License (100,000 procedures) supports unlimited concurrent users and unlimited modality connections. NexoDose is a single server, fully automated system, enabling enterprise-wide ionizing radiation data acquisition that supports Joint Commission standards as well as state regulations. Minimum 90-day warranty. 1 EA 0002 660107 NexoDose Implementation / Network integration (100,000 procedures) creates an automated HL-7 interface to RIS, EMR, dictation/transcription systems, and XML to the ACR's Dose Index Registry (NRDIR). NexoDose Remote Training conducted via WebEx. Minimum 90-day warranty. 1 EA Option Year 1 (to begin at least 90-days after installation and training complete) Line Item Item Number Description Qty Unit 1001 660207 NexoDose Annual Maintenance and support (100,000 procedures) includes all software updates and upgrades as well as 24x7x365 telephone application support and software maintenance. (Post minimum 90-day warranty) 12 MO Option Year 2 Line Item Item Number Description Qty Unit 2001 660207 NexoDose Annual Maintenance and support (100,000 procedures) includes all software updates and upgrades as well as 24x7x365 telephone application support and software maintenance. 12 MO Option Year 3 Line Item Item Number Description Qty Unit 3001 660207 NexoDose Annual Maintenance and support (100,000 procedures) includes all software updates and upgrades as well as 24x7x365 telephone application support and software maintenance. 12 MO Option Year 4 Line Item Item Number Description Qty Unit 4001 660207 NexoDose Annual Maintenance and support (100,000 procedures) includes all software updates and upgrades as well as 24x7x365 telephone application support and software maintenance. 12 MO Delivery: The VA intends to begin products/services with the Clement J. Zablocki VA Medical Center located in Milwaukee, WI, Green Bay Health Care Center located in Green Bay, WI, and Oscar G. Johnson VA Medical Center located in Iron Mountain, MI, but would like to have the option to expand this to all VA facilities in the VISN including Community-Based Outpatient Clinics (CBOCs). Line Item Location All Clement J. Zablocki VA Medical Center 5000 W National Ave Milwaukee, WI 53295 Green Bay Health Care Center 2851 University Ave Green Bay, WI 54311 Oscar G. Johnson VA Medical Center 325 East H Street Iron Mountain, MI 49801 Captain James A. Lovell Federal Health Care Center 3001 Green Bay Rd North Chicago, IL 60064 Edward Hines, Jr. VA Hospital 5000 South 5th Ave Hines, IL 60141 Jesse Brown VA Medical Center 820 S Damen Avenue Chicago, IL 60612 Tomah VA Medical Center 500 E. Veterans Street Tomah, WI 54660 VA Illiana Health Care System 1900 E Main St Danville, IL 61832 William S. Middleton Memorial Veterans Hospital 2500 Overlook Terrace Madison, WI 53705 STATEMENT OF WORK The Clement J. Zablocki VA Medical Center located in Milwaukee, WI, Green Bay Health Care Center located in Green Bay, WI, and Oscar G. Johnson VA Medical Center located in Iron Mountain, MI require a radiation dose monitoring platform to monitor dose delivered by unlimited imaging modalities used at these facilities. The VISN would like to have the option to expand this to all VA facilities in the VISN including CBOCs. SCOPE OF WORK: The VA must implement a patient radiation dose tracking system to improve patient safety and reduce risk of radiation exposure. The system must be able to gather dose information from any ionizing radiation modality sent to our Agfa Healthcare Corporation Impax PACS system and Siemens Medical Solutions USA, Inc. Syngodynamics PACS systems. Images routed from these systems must be analyzed by the system and dose information stored on the exam and patient to a central database. From VA network-connected computers using a web browser, clinicians need to be able to view any patient radiation dose history and diagnostic procedure. The system must be TRM-approved for operation on the VA network and allow for a firm fixed price schedule for expansion of additional modalities and equipment replacement. Training shall be provided remotely by the vendor via the web and have unlimited phone support. Training sessions shall be held for each site and shall be repeated annually. The system application and database shall be located at the VA Milwaukee co-located with the VISN 12 PACS archive to reduce network traffic of large medical images. Vendor shall provide remote assistance for installation in coordination with Clement J. Zablocki VAMC (Milwaukee) Biomedical Engineering staff. Vendor shall approve VPN access to the VA network for remote support. Vendor shall validate all modalities can have dose information extracted within 2 weeks of test images being sent. The VA will provide the virtual server along with OS and database licensing for the product. VA will provide labor to program PACS for route images to the system for processing. SOFTWARE REQUIREMENTS: Software must: Be TRM-approved Have unlimited concurrent users Have web browser interface Have no active controls required by browser (zero footprint) Allow for Active Directory Integration (LDAP) for system security Have unlimited modalities, no additional costs for changes for validation of new modalities IMPLEMENTATION REQUIREMENTS: Each modality shall be validated by sending 2 image sets to the system per modality. Vendor shall provide a schedule for implementation after an information sharing kickoff post award. Vendor shall send an official notice for acceptance after installation and validation processes are completed. Remaining VISN 12 Sites: Edward Hines, Jr. VA Hospital Jesse Brown VA Medical Center William S. Middleton Memorial Veterans Hospital (currently uses Pemnet system) Tomah VA Medical Center VA Illiana Health Care System Captain James A. Lovell Federal Health Care Center (currently uses GE Dosewatch) NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (24-APR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/36C25219Q0535/listing.html)
- Record
- SN05291367-F 20190426/190424230023 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |