SOLICITATION NOTICE
65 -- 2237 REFERENCE NUMBER: 580-19-2-167-0178 OBL JORDAN RESES FIRST N VENTILATOR, V60 TRANSPORT CONFIGURATION PACKAGE WITH CART
- Notice Date
- 5/7/2019
- Notice Type
- Synopsis
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Southeast Louisiana Veterans HCS;1555 Poydras Street;New Orleans LA 70112
- ZIP Code
- 70112
- Solicitation Number
- 36C25619Q0820
- Response Due
- 5/10/2019
- Archive Date
- 6/9/2019
- Point of Contact
- winston.graber@va.gov
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- Respironics V60 Non-invasive ventilator Find similar products The Philips Respironics V60 ventilator is our gold standard hospital dedicated noninvasive ventilator. With advanced breath delivery technology and algorithms designed to maximize performance in a leak prone environment, V60 adapts to your patients ventilation needs. Top of Form I agree on cross-border transfer of personal information. Specifications General General Oxygen inlet pressure range 276 to 600 kPa (40 to 87 psig) Weight with optional battery 10.9 kg (24 lb) Weight without optional battery 10.0 kg (22 lb) Dimensions 33.7 cm H x 39.4 cm W x 42.9 cm D (13.3"H x 15.5" W x 16.5" D) Patient types Patient types Suitability Pediatric ( 20 kg) and Adult Electrical - IntelliBridge EC40/80 Electrical - IntelliBridge EC40/80 AC voltage 100 to 240 VAC AC frequency 50 to 60 Hz AC power 300 V ·A Battery operating time 6 hours in normal conditions Settings Settings C-Flex Off, 1 to 3 IPAP 4 to 40 cm H O CPAP 4 to 25 cm H O EPAP 4 to 25 cm H O Max P (PPV maximum pressure limit) 5 to 40 cm H O IPAP 4 to 40 cm H O Max P (AVAPS maximum IPAP) 6 to 40 cm H O Inspiratory time 0.30 to 3.00 sec Max P (AVAPS maximum IPAP) 6 to 40 cm H O Min P (AVAPS minimum IPAP) 5 to 30 cm H O Min P (AVAPS minimum IPAP) 5 to 30 cm H O Oxygen percentage 21 to 100 % Ramp time Off, 5 to 45 min Respiratory rate 4 to 60 beats per minute Rise time 1 to 5 Triggering and cycling Auto-adaptive (Auto-Trak) or Auto-Trak Plus (optional). Trigger: normal, +1 to +7. Cycle: -2, -1, normal, +1 to +6 AVAPS target tidal volume 200 to 2000 ml BTPS Max E 0 to 100 cm H O/l Max R 0 to 50 cm H Ol/s PPV% 0 to 100 % Max P (PPV maximum pressure limit) 5 to 40 cm H O Max V (PPV maximum volume limit) 200 to 3500 ml Patient Data Patient Data Breath phase/trigger indicator Spontaneous, Timed, Exhale PIP 0 to 50 cm H O Patient/total leak 0 to 200 l/min BTPS Patient Trigger 0 to 100 % Respiratory Rate 0 to 90 beats per minute Ti/Ttot 0 to 91 % Minute volume 0 to 99.0 l/min BTPS Tidal volume 0 to 3000 ml BTPS Waveform window Waveform window Pressure waveform 0 - 50 cm H O Flow waveform 240-2401 /min BTPS Volume waveform 0 - 3,500 ml BTPS Alarm adjustable range Alarm adjustable range Lo Rate (low respiratory rate alarm) 1 - 89 beats per minute Hi Rate (hi respiratory rate alarm) 5 - 90 beats per minute Hi Vr (high tidal volume alarm) 200 - 3,500 ml Lo Vr (low tidal volume alarm) OFF - 1,500 ml HIP (high inspiratory pressure alarm) 5 - 50 cm H O LIP (low inspiratory pressure alarm) OFF, 1 - 40 cm H O LIP T (low inspiratory pressure delay time) 5 - 60 sec Lo VE (low minute ventilation alarm) OFF, 0.1 - 991 /min NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (07-MAY-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/NOrVAMC/VAMCCO80220/36C25619Q0820/listing.html)