Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 12, 2019 FBO #6379
MODIFICATION

W -- USP 800 Mobile Unit Pharmacy Trailer Northport VA Medical Center

Notice Date
5/10/2019
 
Notice Type
Modification
 
NAICS
532120 — Truck, Utility Trailer, and RV (Recreational Vehicle) Rental and Leasing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
36C24219Q0643
 
Response Due
5/15/2019
 
Archive Date
6/14/2019
 
Point of Contact
Contract Specialist
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The purpose of this amendment is to provide answers to submitted questions from interested vendors. This is a Service Disabled Veterans Owned Small Business (SDVOSB) Set-Aside acquisition. Responses to this notice must be submitted in writing (email or fax) and must be received no later than May 15, 2019 at 12:00 pm EST! E-Mail: Andres.cepeda@va.gov No telephone inquiries will be accepted. Interested parties who do not submit that above information on or before the response due date and time will not be considered for this procurement. The specific number of air exchanges listed in the RFP for the Hazardous Drug Buffer Room (40 ACH) and the Anteroom (35 ACH) are over and above the USP 800 compliance requirements. Are those specifically listed design criteria required? Or is the Trailer required to meet all code compliance for a USP 800 Pharmacy?   The Pharmaceutical Mobile Unit is to comply with USP 800 and VA HVAC Design Manual Requirements (whichever is more stringent). For the Hazardous Drug Buffer Room (with the hood ducted to the exhaust fan) 35 ACH. The Ante Room is correct at 35 ACH s. The RFP does specify the number of air exchanges for the Hazardous Drug Buffer Room and the Anteroom, which are over and above the USP 800 requirement; but does not list the design criteria requirement for Non-Hazardous Drug Buffer Room. What is that requirement for the Trailer?   The Pharmaceutical Mobile Unit is to comply with USP 800 and VA HVAC Design Manual Requirements (whichever is more stringent). For the Hazardous Drug Buffer Room (with the hood ducted to the exhaust fan) 35 ACH. The Ante Room requires 35 ACH s. USP 800 does not require a redundant HVAC unit. Your RFP does. Is that accurate? Or do you require meeting the USP 800 and VA HVAC Design Manual and VA Pharmacy Service Design Guide compliance requirements? We will not require a redundant HVAC system as neither USP 800 nor the VA HVAC Design Manual Require it. Is this Pharmacy Trailer required to meet the VA HVAC Design Manual and VA Pharmacy Service Design Guide compliance requirements as other USP 800 & USP 797 Mobile Pharmacy Trailers have been required at other VA locations? Yes. The Pharmaceutical Mobile Unit is to comply with USP 800 and VA HVAC Design Manual Requirements (whichever is more stringent). Is this Pharmacy Trailer required to meet ANSI / ASHRAE / ASHE Standard 170-2017 Ventilation of Health Care Facilities code requirements? No. The Pharmaceutical Mobile Unit is to comply with USP 800 and VA HVAC Design Manual Requirements (whichever is more stringent). Is air from a room less clean than ISO 7 permitted to be mixed with or recirculate into an ISO 7 room? I do not know.   No. Request for double full size refrigerator medical grade.   Can you provide specifics on what you re looking for?   By double do you mean 2 doors, a pass through with doors on each side, or are you looking for a 50 cubic foot lab refrigerator with 2 doors instead of a 25 cubic foot unit with one door?   Two door 50 cubic foot medical grade lab refrigerator Plumbing.   The SOW states the need for heat tracing a domestic cold water line.   If there is a cold water supply line why is there also a need for an on-board fresh water tank?   Water tanks can be a maintenance concern and water sitting in a tank for a period of time isn t recommended for scrubbing.   Could both the cold water supply line and drain lines in the Mobile Cleanroom be connected to the VA s water supply and drain lines, bypassing the need for holding tanks? The Pharmaceutical Mobile Unit will be served by a domestic CW line which the contractor is to provide with heat tracing (50 feet of line). The Pharmaceutical unit shall be equipped with instantaneous domestic HW heaters at the fixtures. Is this solicitation going to require compliance with VA   VHA DIRECTIVE 1108.12 Transmittal Sheet November 5, 2018 -     MANAGEMENT AND MONITORING OF PHARMACEUTICAL COMPOUNDED STERILE PREPARATIONS No. The Pharmaceutical Mobile Unit is to comply with USP 800 and VA HVAC Design Manual Requirements (whichever is more stringent). NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (10-MAY-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/36C24219Q0643/listing.html)
 
Place of Performance
Address: Northport VA Medical Center;79 Middleville Road;Northport NY
Zip Code: 11768
Country: USA
 
Record
SN05308239-F 20190512/190510230034 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.