Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 19, 2019 FBO #6386
SOLICITATION NOTICE

66 -- Field portable X-Ray fluorescence (XRF) analyzer

Notice Date
5/17/2019
 
Notice Type
Combine Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
HQAD<br />US Environmental Protection Agency<br />William Jefferson Clinton Building<br />1200 Pennsylvania Avenue, N. W.<br />Mail Code: 3803R<br />Washington<br />DC<br />20460<br />USA<br />
 
ZIP Code
20460
 
Solicitation Number
68HERH19Q0069
 
Response Due
5/23/2019
 
Archive Date
6/7/2019
 
Point of Contact
Irby, Kenneth
 
Small Business Set-Aside
N/A
 
Description
Subject: Cavity ring down spectrometer Procurement Office: U.S. Environmental Protection Agency. Headquarters Acquisition Division 1200 Pennsylvania Avenue. NW Washington. DC 20460 In accordance with FAR 13.106-1(b), the U.S. Environmental Protection Agency (EPA), Office of Research and Development intends to award a Sole Source Firm Fixed Price Purchase Order for a Cavity Ringdown Spectrometer to Picarro, Inc. The estimated value of this award is $59,050. Picarro, Inc. will manufacture and test a Model 2103 cavity ring-down spectrometer for trace level measurements of NH3 in ambient air meeting the specifications described below: The analyzer must operate on the principle of cavity ring-down spectroscopy. The analyzer must include a pump. The analyzer must weigh 60 pounds or less including pump. The dimensions of the instrument must be no more than 18. wide, 8. high, and 19. deep The analyzer must operate at ambient temperatures up to 35 oC The instrument must have a guaranteed measurement range of 0 ¿ 500 ppb. 1s precision (1 ¿) must be 0.5 ppb or less. 300s precision (1 ¿) must be 0.05 ppb or less. Lower detection limit (3 ¿, 300s) must be <0.1ppb. Zero drift should be ± 0.15 or less over 72 hours and ± 0.5 or less over 1 month. Measurement interval must be 1s. The analyzer is required to guarantee, test, certify, and quote the precision specifications. The analyzer must be operable with normal ambient concentrations of water vapor. Special filtering or gas drying cannot be required. The system must also measure H2O and CO2. The software must include automated water vapor correction. The analyzer must not require any regular optical maintenance such as mirror cleaning The analyzer must have been drop tested and vibration tested during manufacturing to prove ruggedness in the field. There can be no requirements upon the user to ¿tune ¿ the observed spectra or adjust the optics to meet the performance requirements. The instrument must include software necessary for operation of the instrument and data output and visualization. Operation software must report real time data in multiple charts & be developed for the Windows environment This instrument will be deployed in a mobile configuration for measurements of emissions from NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (17-MAY-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/EPA/OAM/HQ/68HERH19Q0069/listing.html)
 
Record
SN05315702-F 20190519/190517230026 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.