Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 24, 2019 FBO #6391
SOLICITATION NOTICE

41 -- Notice of Intent to Perform Oral Solicitations

Notice Date
5/22/2019
 
Notice Type
Synopsis
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
 
ZIP Code
98662
 
Solicitation Number
36C26019Q0428
 
Response Due
5/27/2019
 
Archive Date
6/6/2019
 
Point of Contact
joel.wilson@va.gov
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Page 4 of 4 In accordance with FAR 13.106-1(c )(1), the Department of Veterans Affairs intends to perform oral solicitations for a Traulsen Blast Chiller Model No. TBC1H-20 that will be set-aside for SDVOSBs. To be considered eligible for award all SDVOSB s must be verified through Vetbiz.gov. If you wish to be included in this solicitation, please respond electronically to joel.wilson@va.gov by 3 PM EST Monday May 27th 2019. This solicitation will be performed Tuesday May 28th 2019. This will be a brand name or equal to solicitation to the following Items Manufactured by Traulsen: Item Part Number Description Qty TBC1H-20 Blast Chiller, Roll-in   Traulsen Model No. TBC1H-20      Spec-line Roll-in Blast Ciller with EPICON Control, hold (1) 72 high rack, Self-contained holding refrigeration system, remote chilling refrigeration System, remote chilling refrigeration system not included, chills 150#-250#,hinged left, cULus, NSF 1 115v/60/1ph, 14.9 amps, standard       1 3 year service/labor, 5 year compressor, standard       1 Installation Pump refrigerant down into outdoor condensing unit for existing blast chiller. Secure and disconnect utilities, and cut refrigeration piping out at blast chiller Section.  Remove chiller to back dock. Disposal off site by VA. Cap off  existing refrigeration lines and pressure test. Uncrate, set in place, and level new Traulsen blast chiller. Weld existing refrigeration lines to new unit. Run drain line to existing floor drain.  Reconnect existing electrical. Evaluate existing refrigeration lines after pressure test, and reconnect to new unit.  Start up, test, adjust, and add refrigerant as needed for new blast chiller.               1 Shipping Address: Department of Veterans Affairs VA Southern Oregon Rehabilitation Center 8495 Crater Lake Hwy. White City, OR 97503 To be considered technically acceptable, the products must meet the following minimum salient characteristics: Salient Characteristics Maximum dimensions for unit: H=92 x W=50 x D=38 Stainless Steel Exterior & Interior Construction Magnetic Door Gasket Standard Door Hinging: Left Stainless Steel Breaker Caps Stainless Steel Roll-In Ramp(s) & Rack Guides Self-Closing and Stay-Open Door Features Cam-Lift Hinges Horizontal Work Flow Door Handle On-Board Batch Data Printer Records date/time product reached an acceptable temperature and prints out date stamp label. USB Port for Loading HACCP Data & Product Updates Automatic Refrigerated/Freezer Hold Mode After Each Cycle Two-Stage Self-Contained Refrigeration System Accommodates One Roll-In Rack with Maximum Dimensions Of: H=72" x W=27" x D=29" Unit has an automatic Hot Gas Defrost cycle to prevent ice buildup. Has a condensate tube that will flow into existing floor drain. Must connect to a Copeland Discus compressor/ Model # 2DL3F20KE-TFC-C00 Can chill hot product from 135 °F down to below 41 °F within FDA/HACCP guidelines without freezing. Guidelines are as follows: from 135 °F to 70 °F within two hours, then from 70 °F to below 41 °F within four hours, for a total chill time from 135 °F to below 41 °F of no more than six hours. Maximum capacity for unit during chill cycle is 300 lbs. Has multiple temperature food probes that gauge the temperature of the product placed within the blast chiller cabinet and can display that the product temperature reaches the desired target within a specified time frame. Unit must be able to multi-batch chill with food probes. Has a programable touch screen display. Must be factory tested for performance and are free from defects when shipped. Must be equipped with a power ON/OFF switch. Must have Automatic and Manual chill cycles operations that automatically cool to the right temperature once the probes are inserted and the door closes. This must happen without having to operate a touchscreen. Automatic chill cycle operation is imperative due to work place accommodation created for a sight impaired cook. Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system such that OEM warranty and service are provided and maintained by the OEM. All software licensing, warranty, and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. This procurement is for new Equipment ONLY; no remanufactured or "gray market" items. All Equipment must be covered by the manufacturer's warranty. (a) Gray market items are Original Equipment Manufacturer s (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the medical supplies, medical equipment and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. (c) The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract. Accordingly, the VA reserves the right enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA s election, allowing the Vendor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA medical facility upon discovery of such items. *This notice satisfies the requirement at FAR 5.201 to synopsize proposed contract actions. * NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (22-MAY-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/PoVAMC/VAMCCO80220/36C26019Q0428/listing.html)
 
Place of Performance
Address: VA Southern Oregon Rehabilitation;Center and Clinics;8495 Crater Lake Hwy.;White City, OR
Zip Code: 97503
Country: USA
 
Record
SN05319391-F 20190524/190522230015 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.