Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 26, 2019 FBO #6393
SOURCES SOUGHT

65 -- Active Electrode EEG System Closes 05/30/2019 4:00 PM EST

Notice Date
5/24/2019
 
Notice Type
Synopsis
 
NAICS
541990 — All Other Professional, Scientific, and Technical Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 4;1010 Delafield Road;Pittsburgh, PA 15215
 
ZIP Code
15215
 
Solicitation Number
36C24419Q0747
 
Response Due
5/30/2019
 
Archive Date
6/29/2019
 
Point of Contact
amanda.williams4@va.gov
 
Small Business Set-Aside
N/A
 
Description
Purpose and Objectives: The intent of this Sources Sought Notice is to identify potential small businesses, especially Service Disabled Veteran Owned Small Businesses capable of providing the items as listed in the Statement of Need. NAICS Code 541990 All Other Professional, Scientific, and Technical Services or 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing. These items are for the Department of Veteran Affairs, VA Pittsburgh Healthcare System, University Drive Pittsburgh, PA, 15240. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the attached document. Responses should include the following information: Business name, address, Point of Contact, business size info. All information is to be submitted via email at amanda.williams4@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 4:00 PM EST on Thursday, May 30, 2019. No submissions will be accepted after this date and time. Questions can be submitted electronically to amanda.williams4@va.gov NLT Wednesday, 05/29/2019 3:00 PM EST This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey. STATEMENT OF NEED Product needed: Active Electrode EEG System for Research Applications Item # Description/Part Number* Qty BV-BP-100-2107 ACTICHAMP EEG SYSTEM 1 BP-135-1501 ACTICAP ACTIVE ELECTRODES: 32 CHANNEL BUNDLE 1 BP-235-2205 ACTICAP REPLACEMENT ELECTRODES (SIG) 4 BP-235-2110 ACTICAP REPLACEMENT ELECTRODES (GND) 2 AS-032-C-U-HP-W-54 ACTICAP SNAP CAP (32 CHANNEL; SIZE: 54) 1 AS-032-C-U-HP-W-56 ACTICAP SNAP CAP (32 CHANNEL; SIZE: 56) 1 AS-032-C-U-HP-W-58 ACTICAP SNAP CAP (32 CHANNEL; SIZE: 58) 1 AS-032-C-U-HP-W-60 ACTICAP SNAP CAP (32 CHANNEL; SIZE: 60) 1 BV-BP-MCS-01_03 BIPOLAR ADAPTER KIT 1 PST-101703 E-PRIME 3.0 SINGLE USER UPGRADE LICENSE 1 PST-101761 E-PRIME EXTENSIONS FOR BRAIN PRODUCTS 1 PST-101600 CHRONOS MULTIFUNCTIONAL RESPONSE/STIMULUS DEVICE 1 PST-101873 CHRONOS ADAPTER FOR ACTICHAMP 1 Background This is an equipment purchase related to Dr. Sarah Forster s Career Development Award.   Purpose The requested equipment amplifies, digitizes, and records electrical signals related to neural processes and eye movements/blinks that can be detected at the surface of the scalp and face. We will utilize these data for two primary purposes: (1) electrical signals related to specific brain processes will be examined as predictors of treatment response in a sample of Veterans with cocaine use disorder receiving two versions of an evidence-based intervention for cocaine users (Contingency Management) or standard outpatient care and (2) change in electrical signals related to specific brain processes from pre- to post-treatment will be examined to elucidate neuroadaptive mechanisms underlying treatment response. In order to target specific brain processes of interest in the current study, we will need to record EEG during participant engagement with cognitive-behavioral tasks developed within our lab using VA-approved paradigm design software (E-Prime). In addition, direct communication between E-Prime and the EEG system will be necessary to log task events in the EEG dataset in order to complete proposed analyses. Requirements The system should provide the following: Active Electrodes (amplification of electrical signals at electrode sites) Robust, Water-Tight Construction (active electrodes can withstand required sterilization procedures) Ability to Replace Individual Electrodes Direct Communication with E-Prime (Accurate Event Timing Information is Transmitted to EEG system) Accurately and Reliably Logs Response Time Events Includes at Least 32 EEG Channels + Bipolar Channels for EOG Includes EEG Caps of Different Sizes Quick and Efficient Pre-Acquisition Set-Up Achieves Excellent Signal Quality Without Requiring Scalp Abrasion DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (24-MAY-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24419Q0747/listing.html)
 
Place of Performance
Address: VA Pittsburgh Healthcare System;University Drive Campus;University Drive;Pittsubrgh, PA
Zip Code: 15240
Country: USA
 
Record
SN05322479-F 20190526/190524230014 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.