SOURCES SOUGHT
65 -- Verathon Bladder Scanner with Printer and Cart Closes 06/10/2019 4:00 PM EST
- Notice Date
- 5/29/2019
- Notice Type
- Synopsis
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 4;1010 Delafield Road;Pittsburgh, PA 15215
- ZIP Code
- 15215
- Solicitation Number
- 36C24419Q0760
- Response Due
- 6/10/2019
- Archive Date
- 7/10/2019
- Point of Contact
- amanda.williams4@va.gov
- Small Business Set-Aside
- N/A
- Description
- Purpose and Objectives: The intent of this Sources Sought Notice is to identify potential small businesses, especially Service Disabled Veteran Owned Small Businesses capable of providing the items as listed in the Statement of Need. NAICS Code 339112, Surgical and Medical Instrument Manufacturing. These items are for the Department of Veteran Affairs, Lebanon VA Medical Center in Lebanon, PA 17042. Responses to this Sources Sought Notice should demonstrate the firm's ability, capability, and responsibility to provide the principal components of supplies listed in the attached document. Responses should include the following information: Business name, address, Point of Contact, business size info. All information is to be submitted via email at amanda.williams4@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 4:00 PM EST on Monday, 06/10/2019. No submissions will be accepted after this date and time. Questions can be submitted electronically to amanda.williams4@va.gov NLT Friday, 06/07/2019 3:00 PM EST This is a Sources Sought Notice and submissions will be used for informational and planning purposes only. This notice does not constitute a formal Request for Quote (RFQ), nor is the government obligated to issue an RFQ. In addition, the Government does not intend to pay for any information provided under this notice. The Government is not obligated to notify respondents of the results of this survey. Statement of Need Background: The Lebanon VA Medical Center (LVAMC) has a requirement for three (3) Verathon Bladder Scanners (Bladderscan Prime Plus), three (3) thermal printers and three (3) mobile carts to be utilized in a clinic/procedure room setting. The LVAMC providers presently utilize Verathon s Bladder Scanners which is the preferred model. The Bladderscan Prime Plus is a portable 3D instrument utilized to measure bladder volume. Scope of Work: The Bladder Scanner shall provide quick, accurate information to aid in the diagnosis of common urological condition (e.g., bladder outlet obstruction, lower urinary tract symptoms, overactive bladder, etc.), identify a blocked Foley catheter, assess urinary retention, minimize incontinent episodes, help prevent unnecessary catheterization, and reduce rates of catheter-associated urinary tract infection (CAUTI). The Bladder Scanner shall also be utilized for the monitoring of post-operative urinary retention (POUR). Salient Characteristics of the Bladder Scanner: Shall not require a Sonographer to be operated. Shall be portable and compatible with an optional medical cart with lockable wheels. Shall provide ImageSense 3D image capability analyzing over 900 lines of scan data per scan Pubic Bone Interference indicator Shall have 12 Bmode-slice review Shall have a Liquid Crystal Display (LCD) screen to display bladder volume and position along with an aiming icon with visual/color cues to aide with the probe placement. Shall be battery operated with 2 rechargeable batteries and no console charging required. Shall have an onboard printing mechanism for recording bladder measurements. Shall have a fully sealed probe design Shall meet the following specifications: 1-999ml volume detection +/- 7.5% accuracy on volumes greater than 100ml +/- 7.5ml on volumes less than 100ml Modes: One Button press VMode (3D, multiple, aligned B-mode images) Additional Information: The Verathon model is requested, as this is the type of Bladder Scanner currently used in the clinics and the staff is familiar with its use; therefore, adding another scanner of this type would be beneficial for training purposes and accuracy as the staff use for diagnostic purposes. Delivery: Delivery shall be within thirty (30) days from the time of award. Needed date is 8/30/2019. The Bladder Scanner and accessories shall be delivered to the Lebanon VAMC located at 1700 S. Lincoln Ave., Lebanon, PA 17042; Attn; Warehouse. BioMedical Engineering will need to perform a safety check and enter the equipment in to the system for annual Preventive Maintenance (PM) checks. Placement in the LVAMC clinic shall be coordinated through the Clinical Nurse Manager and/or the Contracting Officer Representative. ITEM DESCRIPTION QTY 0800-0532 Bladderscan Prime Mobile Cart 3 EA 0270-0870 Bladderscan Prime Plus with Standard 5 Yr. Warranty 3 EA 0270-0868 Printer, Therma, Bladderscan Prime 3 EA DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (29-MAY-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24419Q0760/listing.html)
- Place of Performance
- Address: Lebanon VA Medical Center;1700 South Lincoln Avenue;Lebanon, PA
- Zip Code: 17042
- Country: USA
- Zip Code: 17042
- Record
- SN05324997-F 20190531/190529230020 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |