SPECIAL NOTICE
66 -- one (1) Optical Coherence Tomography System (specimen retinal imaging system).
- Notice Date
- 6/4/2019
- Notice Type
- Synopsis
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- US Department of Veterans Affairs;Veterans Health Administration;Regional Procurement Office (RPO) East;323 North Shore Drive, Suite 500;Pittsburgh PA 15212-5319
- ZIP Code
- 15212-5319
- Solicitation Number
- 36C24E19Q0068
- Archive Date
- 9/2/2019
- Point of Contact
- Email: michael.haydo@va.gov
- Small Business Set-Aside
- N/A
- Description
- The Veteran s Administration (VA) Office of Research and Development, Regional Procurement Office East in Pittsburgh, PA intends to negotiate on a sole source basis with Netra systems, Inc. based in Pleasanton, CA on behalf of the Western New York Healthcare System. The requirement is to provide one (1) Optical Coherence Tomography System (specimen retinal imaging system) for planned VA medical studies. Salient Characteristics Optical Coherence Tomography System (Multidimensional Mouse Retinal Imaging System) System Description The requirement is for one (1) Optical Coherence Tomography System (Multidimensional Mouse Retinal Imaging System) with specifications that meet or exceed those listed in the specifications section. This instrument shall be delivered and installed at the VA Western NY Medical Center Research Service. Specifications The vendor shall supply instrumentation that meets or exceeds the following specifications: A fully-integrated, wide-field mouse retinal imaging system that simultaneously exploits a variety of imaging techniques (optical coherence tomography (OCT), adaptive optics (AO), scanning laser ophthalmoscopy (SLO)) to accomplish multiple real time imaging modalities that includes, b-scan OCT, fundus autofluorescence (FAF) in arbitrary fluorescent bands, adaptive optics (AO) applied to OCT and SLO measures, angiographic OCT, real time fluorescein angiography, arbitrary retinal fluorescence measures, and fundus photography. Generate ultra-high resolution images at 2x2x2 mm voxels of the mouse retina under the variety of imaging modalities. Multi-element optics designed to precisely image the mouse retina under the multiple modality imaging conditions. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (04-JUN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/notices/773c9461ed1a40b2377b37b78a7ba9b3)
- Record
- SN05330802-F 20190606/190604230029 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |