Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 09, 2019 FBO #6407
SOURCES SOUGHT

J -- Galley Hood Degreasing Services

Notice Date
6/7/2019
 
Notice Type
Synopsis
 
NAICS
561790 — Other Services to Buildings and Dwellings
 
Contracting Office
Department of Veterans Affairs;Gulf Coast Veterans Health Care System;Network Contracting Office 16;400 Veterans Avenue;Biloxi MS 39531
 
ZIP Code
39531
 
Solicitation Number
36C25619Q0975
 
Response Due
6/14/2019
 
Archive Date
7/14/2019
 
Point of Contact
Contracting Officer
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
This is a SOURCES SOUGHT NOTICE ONLY. This SOURCE SOUGHT NOTICE is for the purpose of Market Research. Response to this notice will be used for information and planning purposes. No proposals or quotes are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS or QUOTES and NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall NOT be construed as solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). Responses to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Network Contracting Office (NCO) 16 is seeking preferably Service Disabled Veteran Owned Small Businesses, or Small Businesses (but will accept other than small business for market research purposes), capable of providing inspection, cleaning and documentation of Canteen Hood and Degreasing Exhaust Vent System on Canteen equipment services for the Gulf Coast Veterans Health Care System, Biloxi, MS and the Joint Ambulatory Care Center (JACC), Pensacola, FL 32507. See DRAFT Scope of Work for detailed description of services. The NAICS code is 561790  Other Services to Buildings and Dwellings and the Size Standard is $7.5M. Responses must be received by no later than 12:00 p.m. Central Time, Friday, June 14, 2019. Responses shall be emailed to rene.impey@va.gov. Responses shall include Capabilities Statements, DUNS number, and whether the requirement is on GSA/FSS schedule or Open Market. Facsimile or Telephonic responses will not be accepted. Note: All interested parties are reminded to be registered, active and verified in the following to be considered for Award. SAM: https://www.sam.gov/portal/public/SAM/ VETBIZ: https://www.vip.vetbiz.gov/Public/Search/Default.aspx Vet 4212 (Veteran owned small Business are reminded of Reporting Requirements) https://www.dol.gov/vets/vets4212.htm DRAFT - SCOPE OF WORK Canteen Hood Inspection, Testing and Degreasing Gulf Coast Veterans Health Care System Biloxi, MS, and Pensacola, FL Perform Inspection, Cleaning and Documentation of Canteen Hood and Degreasing Exhaust Vent System on Canteen equipment in accordance with NFPA 101 and NFPA Standard 96. Inspection, Testing and Maintenance (ITM) tasks (identified below), should be performed by craftsperson s trained/qualified in the ITM and repair of the subject fire protection systems or subsystems. Contractor to perform Annual and Semiannual Inspection and Testing of Canteen hood equipment. Additionally, Contractor shall also perform quarterly degreasing maintenance on all Canteen hood equipment (locations shown below), including, fans ducts and other appurtenances to remove combustible contaminants. All written reports are due back to facility within 48 hours of ITM and cleaning of systems. Tasks: Cleaning/Degreasing Cover all equipment prior to cleaning process Canteen hoods, fans, ducts, and other appurtenances shall be cleaned to remove combustible contaminants Polish ventilation hoods and all applicable ductwork Place all required certification tags of equipment Ensure entire area is cleaned after cleaning/degreasing of canteen equipment systems Hood Suppression Testing Test actuation and control of components, including remote pull stations and mechanical electrical devices, detectors and actuators Change all fusible metal alloy links Service suppression extinguishing agent/extinguishers as needed Ensure entire area is cleaned after inspection, testing and maintenance of canteen equipment systems. JACC Canteen Pensacola, FL Semiannual testing and inspection to be performed February & August. Quarterly cleaning & degreasing to be performed February, May, August, November. Dining Hall and Canteen area (Bldg. 21) Biloxi, MS Semiannual testing and inspection to be performed February & August of each year of contract. Quarterly cleaning & degreasing to be performed in December, March, June and September of each year of contract. Nutrition and Food Service (Building 31) Biloxi, MS Semiannual testing and inspection to be performed February & August of each year of contract. Due to lack of grease cooking in area, the ventilation system in bldg. 31 will need to be inspected for grease accumulation during the months December March and June and an actual cleaning conducted during the month of September each year. CLC (Bldg. 15) Biloxi, MS (Small Stand-Alone Stove with Hood Suppression System) Semiannual testing and inspection to be performed February & August. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (07-JUN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/BiVAMC/VAMCCO80220/36C25619Q0975/listing.html)
 
Place of Performance
Address: Department of Veterans Affairs;Gulf Coast Veterans Health Care System;400 Veterans Avenue;Biloxim, MS
Zip Code: 39531
Country: USA
 
Record
SN05334669-F 20190609/190607230019 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.